User manual VITEK VT-EH

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual VITEK VT-EH. We hope that this VITEK VT-EH user guide will be useful to you.


VITEK VT-EH : Download the complete user guide (9317 Ko)

You may also download the following manuals related to this product:

   VITEK VT-EH DATASHEET (1510 ko)

Manual abstract: user guide VITEK VT-EH

Detailed instructions for use are in the User's Guide.

[. . . ] 500 mA) CAUTION RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE. DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS 1 Installation should be carried out only by qualified personnel and in accordance with any electrical regulations in force at the time. The DVR must be placed on a stable surface or mounted in an approved cabinet. Adequate ventilation must be provided, taking particular care not to block any of the air vents on the DVR. Adequate protection against lightning strikes and power surges must be installed to prevent damage to the DVR. Any safety warnings on the DVR and in these instructions must be adhered to. If cleaning is necessary, shutdown the DVR and disconnect power first. Use a soft dry cloth only never use any abrasive cleaners. Do not attempt to service or repair the DVR as opening or removing covers may expose dangerous voltages or other hazards. Refer all servicing to qualified service personnel. 2 MOUSE CONTROLL Designed to be controlled by mouse and easy to use. ENHANCED GRAPHICAL USER INTERFACE [GUI] The DVR menu structure and on screen display is presented in a simple to use and logical GUI format. [. . . ] Then `Sequence Setup" window will appear again. The new sequence is now saved and can be started by pressing the SEQ button when in live view. 22 DISPLAY : SPOT-OUT Click the SPOT-OUT menu and click the camera channel for ON/OFF. The DVR has 4 SPOT MONITOR OUTPUTS (Digital Spot). User can assign the SPOT OUT display each channel. Double click the spot out channel that requires to be assign. SPOT TITLE: input the title. ACTIVATION: Determines ON/OFF. Press MODIFY. (Below is default setup) To modify the current display, double click this display. Then `Spot Sequence Setup" window will appear. How to setup is same with Sequence setup. (User can assign Single and Quad display only) To add the additional display, press ADD. 23 SOUND Click the SOUND menu. To setup the various sound options, highlight SOUND and press ENTER SOUND : AUDIO Click the AUDIO menu and click the ON/OFF menu. Then, click the for ON/OFF. button LIVE AUDIO : When it is set to ON, the selected audio channel can be monitored on the AUDIO OUTPUT. AUDIO MONITORING CHANNEL : Specify which one of the 4 AUDIO INPUTS is routed to the AUDIO OUTPUT. NETWORK AUDIO TX : When set to ON, live and playback audio is transmitted to a remote PC connection. NETWORK AUDIO RX : When set to ON, allows a remote PC connection to send audio back to the DVR. SOUND : BUZZER Click the BUZZER menu and click the ON/OFF menu. Then, click the ON/OFF. button for KEYPAD: When it is set to ON, each front panel button press is confirmed by a beep. 24 SYSTEM Click the SYSTEM menu. To setup the various system options, highlight SYSTEM and press ENTER. SYSTEM : DATE / TIME Click the DATE / TIME menu. DATE TIME : Allows the operator to set or modify the current date & time. DATE FORMAT : Determines how the date is displayed. TIME FORMAT : Determines how the time is displayed. NETWORK TIME SERVER SETUP : If the DVR is connected to the Internet, the time and date can be accurately set by selecting SYNC and pressing ENTER. TIME ZONE SETUP : It should be set according to the region, which the DVR is used in. D. S. T. : When it is set to ON, the DVR will automatically adjust the time by one hour on the relevant date in spring and autumn. 25 SYSTEM : SYSTEM MANAGEMENT Click the SYSTEM MANAGEMENT men u. SYSTEM INFORMATION: User can see the system information as below. F/W version : Shows the firmware version of the DVR. H/W version : Shows the hardware version of the DVR. VIDEO SIGNAL TYPE : The DVR automatically switches between PAL and NTSC depending on the channel 1 input signal at power on. DISK CAPACITY : The first value shows the amount of hard drive capacity used by recorded footage, t he second value shows the total hard drive capacity installed. IP ADDRESS : Shows either the manual IP address entered in NETWORK setup or the IP address assigned by a DHCP server if enabled. MAC ADDRESS : Shows the MAC (Media Access Control) address of the DVR. It is unique ­ no other network device has this MAC address. DDNS DOMAIN NAME: If DDNS is enabled, the host DDNS server is specified here. NET CLIENT PORT : The port number that the DVR uses to support remote connection from the client software. WEB SERVER PORT : The port number that the DVR uses to support remote connection from Internet Explorer or other web browsers. 26 SYSTEM NAME : It is used so that notification emails can be identified. F/W UPDATE : Firmware updates may be released periodically to enhance system performance and add extra features. The operator can upgrade the firmware using a USB memory stick. After inserting the F/W in USB or CD/DVD, Press UPDATE. Then , below menu will appear. After selecting the F/W from F/W list, press UPGRADE. Then, F/W upgrade is started. FACTORY DEFAULT : If settings have been changed , which cause erratic behavior, the factory default settings can be loaded. SYSTEM DATA : System settings can be saved to a USB memory stick. The settings can be reloaded in case of accidental factory reset or can be transferred to another DVR if multiple units need to be installed with the same settings. All information is saved apart from network settings and system name. PASSWORD: Determines the PASSWORD ON/OFF to enter specific menu. SYSTEM : CONTROL DEVICE This will allow up to 254 DVRs to be controlled from the same keyboard. SYSTEM ID : If more than one DVR is connected on the same RS485 bus, each one must have a uniq ue ID. Note : If use more than one DVR on stack, each DVR must have unique ID for control by Remote cont roller. PROTOCOL : Must be set by Control Device. BAUD RATE : Must be set to match the baud rate of the PTZ controller. 27 USER Click the USER menu. To setup the various system options, highlight USER and press ENTER. USER: USER MANAGEMENT By default, the DVR is configured with a user ID of ADMIN, belonging to the ADMIN group and with a password of 1234. As well as the ability to add new users, existing user details can be modified. To modify user details, highlight the user with the green cursor and press ENTER. The user number that can create is Max. 8 users. For edit, double click on the each tap. After changing, click OK. USER ID : Edit the user ID using the virtual keyboard. 10 characters) PASSWORD : Change the password using the virtual keyboard. 4 Characters) GROUP : Users can belong to one of three groups - ADMIN, MANAGER or USER. E-MAIL : Enter the users email address if email notification is required. 64 Characters) E-MAIL NOTIFICATION : Enable or disable email notifications for this particular user. 28 For ADD, double click on the each tap after clicking ADD. After changing, click OK. USER ID : Edit the user ID using the virtual keyboard. PASSWORD : Change the password using the virtual keyboard. GROUP : Users can belong to one of three groups - ADMIN, MANAGER or USER. E-MAIL : Enter the users email address if email notification is required. E-MAIL NOTIFICATION : Enable or disable email notifications for this particular user. USER: USER AUTHORITY User can give the authority to the MANAGER and USER. To select authority, click the APPLY button after selecting each items. Please note: Any user can be deleted except the default ADMIN user. USER: LOG OUT AUTO LOGOUT: Determines the AUTO LOGOUT ON/OFF. DURATION: In case of selecting AUTO LOGOUT ON, determines the duration. 29 NETWORK Click the NETWORK menu and determines each value. NETWORK: IP SETUP Click the IP SETUP menu. DHCP : When enabled, the DVR will obtain an IP address automatically if it is connected to a DHCP server or router. WEB SERVICE : When enabled, it allows remote connections using Internet Explorer or other web browsers. IP ADDRESS : If DHCP is not being used, the IP address can be manually set. GATEWAY : If DHCP is not being used, the gateway IP address can be manually set. SUBNET MASK: If DHCP is not being used, the subnet mask can be manually set. 1ST DNS SERVER : If DHCP is not being used, the first DNS server can be manually set. 2ND DNS SERVER : If DHCP is not being used, the second DNS server can be manually set. RTSP SERVICE PORT : If connected Router support UP&P (Universal plug and play) function, when you click the AUTO PORT, the port forwarding is automatically setup. And also can delete the port & test the port whether working or not. WEB SERVER PORT : : If connected Router support UPNP (Universal plug and play) function, when you click the AUTO PORT, the port forwarding is automatically setup. The port number that the DVR uses to support remote connection from Internet Explorer or other web browsers. ALIAS : When you enter the DDNS HOST NAME in DDNS setup (Next page), you can see the information like below. example: 1234. dvrlink. net:8080 MAX TX SPEED : Specifies the maximum bandwidth that the DVR can use during a remote connection. 30 NETWORK: DDNS DDNS : When enabled, the DVR can be accessed through a Dynamic DNS server. Commonly used if a broadband connection does not have a static IP address. DDNS HOST NAME : User can enter any name to connect by web broswer. NETWORK: E-MAIL Click the E-MAIL menu. SERVER : The SMTP outbound email server that should be used to send email notifications. PORT : The outbound email port number. SECURITY : Set to OFF if the SERVER does not require a username and password to connect. USER : Enter a username to identify the DVR in email messages. PASSWORD : If SECURITY is set to ON, enter the password here. FROM: Input the E-mail address or any text. [. . . ] Then below menu will appear again. RESERVE: Press this to reserve current data. CONTINUE: Press this to reserve the data more. Then display will be return to playback. STOP: Make sure to press this button to reserve current data firstly. Then user can select the RESERVE. START: Press this to start the reserve. CLOSE: Finish the archiving. Reserved data will be reserved in HDD. User can see the reserved data from "RESERVED DATA MANAGEMENT" of ARCHIVING menu To exit playback mode and return to the search screen to choose another time an d date, press RETURN. To exit the search screen and go back to live view, repeatedly press RETURN. 48 SEARCH : EVENT SEARCH The DVR event log stores events such as motion and alarm activated recording, video loss etc. To search for an event and playback the recorded footage, press the SEARCH button and log in as ADMIN with the default password of 1234. Click the SEARCH BY EVENT menu and each value. Then click the value by button to change. Click the SEARCH menu. Playback resumes from the moment when the selected event occurred and continues until stoppe d by the operator. During event search playback, the SHUTTLE WHEEL, JOG RING and playback buttons can be used as normal. To stop playback and return to live view mode, repeatedly press RETURN. 49 NEW ARCHIVING To archive recorded footage to USB memory stick or CD/DVD, press the ARCHIVE button. To protect unauthorized viewing and distribution of footage, only the ADMIN user level can archive footage. To login as ADMIN, enter the default password of 1234 and press ENTER. Click the each value. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE VITEK VT-EH




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual VITEK VT-EH will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.