User manual THOMSON TSC 800 V2.1

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual THOMSON TSC 800. We hope that this THOMSON TSC 800 user guide will be useful to you.


THOMSON TSC 800 V2.1: Download the complete user guide (1025 Ko)

You may also download the following manuals related to this product:

   THOMSON TSC 800 V2.1 (1319 ko)
   THOMSON TSC 800 V2.1 (507 ko)
   THOMSON TSC 800 V2.1 (1374 ko)
   THOMSON TSC 800 V2.2 (1031 ko)

Manual abstract: user guide THOMSON TSC 800V2.1

Detailed instructions for use are in the User's Guide.

[. . . ] TSC 800 TRANSFER SWITCH CONTROLLER INSTALLATION, OPERATING & SERVICE MANUAL Software Version 2. 1 PM049 REV 9 06/04/24 9087A ­ 198 Street, Langley, BC Canada V1M 3B1 Telephone (604) 888-0110 Telefax (604) 888-3381 E-Mail: info@thomsontechnology. com www. thomsontechnology. com th 9087A ­ 198 Street, Langley, BC Canada V1M 3B1 Telephone (604) 888-0110 Telefax (604) 888-3381 E-Mail: info@thomsontechnology. com www. thomsontechnology. com th TSC 800 TRANSFER SWITCH CONTROLLER TABLE OF CONTENTS 1. PRODUCT REVISION HISTORY GENERAL DESCRIPTION 1 1 2 2. INSTALLATION 2. 1. GENERAL INFORMATION NOTES TO INSTALLER AC VOLTAGE SENSING INPUT AC CONTROL POWER INPUT OUTPUTS SYSTEM PHASING-HIGH LEG DELTA SYSTEMS EXTERNAL PANEL CONTROL WIRING REMOTE START CONTACT FIELD WIRING COMMMUNICATION CABLE DIELECTRIC TESTING 5 5 5 6 6 7 7 10 10 11 12 3. DESCRIPTION 3. 1. SYSTEM TIME MENU ATS MODE MENU TSC 800 PROGRAM MENU SYSTEM OPERATION MENU TIMER COUNTDOWN MENUS 16 19 19 20 23 23 25 Thomson Technology PM 049 REV 9 06/04/24 TSC 800 TRANSFER SWITCH CONTROLLER 5. 6. [. . . ] NOTE: PM 049 REV 9 06/04/24 43 Thomson Technology TSC 800 TRANSFER SWITCH CONTROLLER Week Number is programmable only if the System Time Clock Rollover period is set longer than 7 days. Ensure Auto Test Stop Day/Week/Timer occurs after the Auto Test Start Day/Week/Timer setting (Generally of the same day/week) otherwise the generator may operate for an extended period of time. 7. 2. 6. 0-23 hour) that the generator set is to be stopped following its exercise period. 7. 2. 7. 0 to 59 minutes) that the generator set is to be stopped following its exercise period. 7. 2. 8. Three test modes are available as follows: Auto: Off Load: The exercise test mode is de-activated The generator set will be started during the exercise period but no transfer will occur. NOTE: The generator will transfer on load if the utility supply fails during the test period. On Load: The generator will be started and will transfer on load. NOTE: During the On-Load exercise test mode, the transfer switch will automatically re-transfer back to the utility supply if the generator set fails. 7. 3. SYSTEM CONFIGURATION The TSC 800 controller provides a flexible control system to allow specific operation for a wide range of power distribution types. To program the system configuration, refer to the following descriptions: 7. 3. 1. FIRMWARE VERSION "Display Only" - The Controller's current firmware version number and date of release. PM 049 REV 9 06/04/24 44 Thomson Technology TSC 800 TRANSFER SWITCH CONTROLLER 7. 3. 2. ATS MODE MENU PASSWORD (PW) NOTE: The following features is provided in TSC 800 Software version 2. 0 (or higher). Allows setting of Password Protection restricting access to the ATS Mode Menu as follows: ENABLED: Access to initiating/changing any test or operation mode requires a userentered password. DISABLED: The ATS Mode Menu may be entered and changes made/initiated without the use of a security password. 7. 3. 3. UTILITY FAIL CALLOUT NOTE: The following features are viewable only in Master Read / Write Mode in TSC 800 Software version 2. 0 (or higher). When the remote communication option is enabled, this programming prompt will appear. ENABLED: The controller will initiate a callout signal via the communication port to a remote connected device when a Utility (Source 1) power failure is detected. The callout signal will be reset when the Utility (Source 1) power returns to normal condition. DISABLED: The controller will not initiate a callout when a Utility (Source 1) power failure is detected. 7. 3. 4. LOAD ON GENERATOR CALLOUT When the remote communication option is enabled, this programming prompt will appear. ENABLED: The controller will initiate a callout signal via the communication port to a remote connected device when the load is connected to the generator supply. The callout signal will be reset when the load transfers back to the utility supply. DISABLED: The controller will not initiate a callout when the load transfers to the generator supply. PM 049 REV 9 06/04/24 45 Thomson Technology TSC 800 TRANSFER SWITCH CONTROLLER 7. 3. 5. TRANSFER FAIL CALLOUT When the remote communication option is enabled, this programming prompt will appear. ENABLED: The controller will initiate a callout signal via the communication port to a remote connected device when the transfer switch fails to operate. The callout signal will only reset when the "Fail to Transfer" alarm is manually reset via local pushbuttons or with the remote communication software. DISABLED: The controller will not initiate a callout when a "Fail to Transfer " alarm condition occurs. 7. 3. 6. AUTO TEST CALLOUT When the remote communication option is enabled, this programming prompt will appear. ENABLED: The controller will initiate a callout signal via the communication port to a remote connected device when a automated test is initiated at the controller via the TSC 800 exercise time clock. The callout signal will reset when the Auto Test condition is terminated. [. . . ] No neutral positioning will be detected and no NDT applied as a result (normal condition). High residual voltage from the connected loads (neutral position can not be determined). Verify the TSC 800 has not been set for a manual or auto off load test operation. If yes, select "Auto" ("None" in firmware versions 1. 7 and earlier). [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE THOMSON TSC 800




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual THOMSON TSC 800 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.