User manual THOMSON TSC 80 V2.1

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual THOMSON TSC 80. We hope that this THOMSON TSC 80 user guide will be useful to you.


THOMSON TSC 80 V2.1: Download the complete user guide (275 Ko)

You may also download the following manuals related to this product:

   THOMSON TSC 80 V2.2 (275 ko)

Manual abstract: user guide THOMSON TSC 80V2.1

Detailed instructions for use are in the User's Guide.

[. . . ] TSC 80 TRANSFER SWITCH CONTROLLER INSTALLATION, OPERATING & SERVICE MANUAL Software Version 2. 1 PM063 Rev 6 09/01/01 9087A ­ 198 Street, Langley, BC Canada V1M 3B1 Telephone (604) 888-0110 Telefax (604) 888-3381 E-Mail: info@thomsontechnology. com www. thomsontechnology. com th TSC 80 TRANSFER SWITCH CONTROLLER TABLE OF CONTENTS 1. SYSTEM VOLTAGE SYSTEM PHASING-HIGH LEG DELTA SYSTEMS REMOTE START CONTACT FIELD WIRING DIELECTRIC TESTING 1 1 2 3 3 3 3 4 5 2. DESCRIPTION 2. 1. TERMINAL BLOCKS DIAGNOSTIC LED'S ADJUSTMENT POTENTIOMETERS CONFIGURATION JUMPERS 6 6 8 8 9 10 10 2. 3. UTILITY POWER FAIL SIMULATION (LOAD TEST) AUTOMATIC PLANT EXERCISE TEST FOUR FUNCTION REMOTE TEST (FTS4 OPTION) REMOTE TEST 17 17 18 19 20 3. 3. [. . . ] To initiate a 30 minute /7 day weekly automatic plant exercise mode, press the GENERATOR EXERCISE Mode pushbutton on the Lexan faceplate. Hold the pushbutton on for approximately 5 seconds until the LED light above the pushbutton changes state. Once the mode is initiated, the engine will immediately start and transfer on load (i. e. if configured for On Load Test) once nominal voltage and frequency levels have been obtained. The engine will remain operating on load until the plant exercise time delay period of 30 minutes expires, then the load will re-transfer back to the utility supply. The engine will be automatically re-tested on load every week (e. g. 7 days) at the same time of day. The load will automatically re-transfer to the utility supply should the generator fail while in the test mode. To bypass a 30-minute exercise run period, press and hold the Exercise pushbutton on for 5 seconds until the LED remains on. The Generator Exercise LED light will operate as follows: LED ON - Exercise Timer is initiated, the 7-day timer is active and the generator is in the off state. LED FLASHING - Exercise Timer is initiated, the 30 minute run timer is active and the generator is running on loads. LED OFF - Exercise Timer is not initiated and the 7-day timer is not active. PM063 Rev 5 09/01/01 18 Thomson Technology TSC 80 TRANSFER SWITCH CONTROLLER To terminate the Generator Exercise Mode, the Exercise pushbutton must be held on for approximately 5 seconds until the LED light above the pushbutton starts flashing. When the pushbutton is released, the LED light will go out and the system will return to normal operation. NOTE To enable the Auto Exercise mode without initiating an immediate exercise test, operator must first turn the gen set engine control to off, then press the Exercise button once, then press it a second time to cancel the test. The gen set engine control should then be returned back to the Automatic position. 3. 2. 3. FOUR FUNCTION REMOTE TEST (FTS4 OPTION) The function of the Four Position Test Switch Input is to allow operators to select various operating scenarios for test or maintenance purposes, in addition to the use of the faceplate mounted pushbuttons. NOTE: When an external FTS4 switch is used, the TSC 80 operation as selected from the faceplate pushbuttons will be overridden. If the primary source is available, and within normal limits, the TSC 80 will initiate a transfer to the primary source. The transfer switch will not automatically transfer to the secondary (alternate) source should the primary source fail. AUTO: All automatic functions are enabled. ENGINE START: (No load test) An engine start signal will be initiated and will remain on until the FTS4 is placed in another position. The engine will start if the engine's auto start controller is in the "Auto" mode. If the primary source fails in this mode, and the secondary source is within parameters, the TSC 80 will initiate a transfer to the secondary source. When the Engine Start input is removed, the generator will continue to run if it has not operated for a time equal to or greater than the minimum run time (i. e. [. . . ] MAX. A (L1) 1 24 SYSTEM GROUND UTILITY SUPPLY SENSING 120-600VAC 50/60Hz 3 PHASE 1 B (L2) 2 28 C (L3) 3 27 ENGINE START CONTACT (Contact closes to start engine on power failure) RATED 10A, 120/250VAC, 5A, 30VDC RES. MAX. A (L1) 4 GENERATOR SUPPLY SENSING 120-600VAC 50/60Hz 3 PHASE 1 B (L2) 5 C (L3) 6 16 A (L1) 7 15 LOAD ON GENERATOR RATED 10A, 120/250VAC, 5A, 30VDC RES. MAX. 14 LOAD SENSING 120-600VAC 50/60Hz 3 PHASE B (L2) 8 13 C (L3) 12 9 11 LOAD ON UTILITY RATED 10A, 120/250VAC, 5A, 30VDC RES. MAX. COMMON SYSTEM NEUTRAL OR GROUND REFERENCE N 10 1 UTILITY AND GENERATOR SUPPLIES MUST UTILIZE A SOLIDLY GROUNDED NEUTRAL SYSTEM. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE THOMSON TSC 80




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual THOMSON TSC 80 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.