User manual THOMSON TS 880

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual THOMSON TS 880. We hope that this THOMSON TS 880 user guide will be useful to you.


THOMSON TS 880 : Download the complete user guide (797 Ko)

Manual abstract: user guide THOMSON TS 880

Detailed instructions for use are in the User's Guide.

[. . . ] TS 880 AUTOMATIC TRANSFER SWITCHES INSTALLATION, OPERATING & SERVICE MANUAL PM064 REV 8 10/01/25 9087A ­ 198th Street, Langley, BC Canada V1M 3B1 Y Telephone (604) 888-0110 Telefax (604) 888-3381 Y E-Mail: info@thomsontechnology. com Y www. thomsontechnology. com TS 880 TRANSFER SWITCH TABLE OF CONTENTS 1. UPSTREAM CIRCUIT PROTECTIVE DEVICES/ELECTRICAL CONNECTIONS TRANSFER SWITCHES WITH INTEGRAL OVER CURRENT PROTECTION TRANSFER SWITCHES WITH MULTI-TAP VOLTAGE CAPABILITY SYSTEM PHASING-HIGH LEG DELTA SYSTEMS REMOTE START CONTACT FIELD WIRING DIELECTRIC TESTING MOUNTING OF ENCLOSED TRANSFER SWITCHES 2 2 3 3 4 5 6 6 4. GENERAL DESCRIPTION 4. 1. PRODUCT MODEL CODE TYPICAL COMMISSIONING PROCEDURES 9 10 11 5. GENERAL THEORY OF OPERATION 5. 1. TEST MODES 11 11 11 12 16 16 17 17 19 21 PM064 REV 8 10/01/25 Thomson Technology TS 880 TRANSFER SWITCH 6. OVER CURRENT PROTECTION 6. 1. [. . . ] Electrical conductors are adequately secured away from moving parts. To maintain operational integrity, ensure that: q q All control devices are in good condition and correctly calibrated. All control devices are adequately secured in their plug-in fixtures. Failure to correctly maintain an automatic transfer switch may present a hazard to life and equipment. Full operational testing must be done prior to placing a transfer switch in service subsequent to any maintenance or repair. Any service work involving electrical components requires high-potential testing to ensure that 7. 1. 3. MANUAL OPERATION DANGER!!!! PM064 REV8 10/01/25 24 Thomson Technology TS 880 TRANSFER SWITCH Arc Flash and Shock Hazard. Do not open equipment until ALL power sources are disconnected This equipment must be installed and serviced only by qualified electrical personnel utilizing safe work practices and appropriate Personal Protective Equipment (PPE). Failure to do so may cause personal injury or death Isolate the transfer switch from all sources of supply before opening the enclosure for manual operation. With all sources of power de-energized to the transfer switch, the control circuit isolation plug can be unplugged to prevent subsequent operation. The control circuit isolation plug is located on the inner side of the transfer switch enclosure door. To operate manually, insert the operating handle into the square hole on the front of the mechanism and rotate to the desired position. Remove the operating handle once operation is complete and re-insert into the handle holder on the left-hand side of the transfer switch mechanism. Automatic operation may be regained by replacing the control circuit isolation plug. With all sources of power de-energized to the transfer switch, the control circuit isolation plug can be re-connected. The drive system will operate the transfer switch to the required position. switch mechanism. ) (See manual operation instruction on front of transfer 7. 1. 4. Do not open equipment until ALL power sources are disconnected This equipment must be installed and serviced only by qualified electrical personnel utilizing safe work practices and appropriate Personal Protective Equipment (PPE). Failure to do so may cause personal injury or death PM064 REV8 10/01/25 25 Thomson Technology TS 880 TRANSFER SWITCH q DO NOT perform dielectric tests on the equipment with the control components in the circuit. q q Check if control components are tight in sockets. Periodically inspect all terminals (load, line and control) for tightness. Clean or replace any contact surfaces, which are dirty, corroded or pitted. q Transfer switches should be in a clean, dry and moderately warm location. Should dust and/or debris gather on the transfer switch, brush, vacuum, or wipe clean. DO NOT blow dirt into power switching devices. q Test the transfer switch operation. While the unit is exercising, check for freedom of movement, hidden dirt, corrosion or any excessive wear on the mechanical operating parts. Ø Verify all program settings on the TSC 800 controller are as per the programming sheet supplied with the transfer switch. [. . . ] In preparation for operation, turn the generator's engine control switch to the "Automatic" start position. 16) To transfer the generator on load, perform a load test by entering the ATS MODE MENU, selecting "YES" on the TSC 800 display, then selecting "ON LOAD" test, then enter. The engine should start following the 3-second engine start delay period and the transfer switch will begin transferring to the generator supply once the 2-second engine warm-up timer expires. Note: the engine warm-up timer will only begin timing once the generator's output rises above 90% nominal voltage and 90% nominal frequency. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE THOMSON TS 880




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual THOMSON TS 880 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.