User manual THOMSON MPC-ETN QUICK INSTALLATION GUIDE

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual THOMSON MPC-ETN. We hope that this THOMSON MPC-ETN user guide will be useful to you.


THOMSON MPC-ETN QUICK INSTALLATION GUIDE: Download the complete user guide (555 Ko)

Manual abstract: user guide THOMSON MPC-ETNQUICK INSTALLATION GUIDE

Detailed instructions for use are in the User's Guide.

[. . . ] Quick Installation Guide for MPC-ETN The Thomson Technology MPC-ETN is a multi-protocol converter and Serial ­Ethernet media converter. This Quick Installation Guide will describe the method to interface a PC to either a MEC 20 or TSC 800 controller over an RS485/232 serial interface. Check Components: Unpack and ensure that all components are in good condition. Qty Description 1 MPC-ETN protocol converter 2 RJ45 to DB9M Converter 1 RJ45 to DB9F Converter 1 6ft Ethernet Cable (CAT5) 1 10ft Ethernet Cable (CAT5) 1 Software & Documentation CD-ROM Gateway Utility Software ­ Download the latest from www. thomsontechnology. com Customer Required Components: Qt y 1 1 Description Ethernet Cable 24VDC power supply (min 12Vdc, max 30Vdc), 100mA max. NOTES: 1. [. . . ] Refer to Step 4 of `Setting the ModbusTM node address (default 1) and TCP/IP address:' THOMSON TECHNOLOGY 9087A ­ 198 STREET, LANGLEY, BC CANADA V1M 3B1 TELEPHONE: (604) 888-3381 EMAIL: info@thomsontechnology. com www. thomsontechnology. com PM086 REV 1 08/08/28 th Quick Installation Guide for MPC-ETN Setting the ModbusTM node address (default 1) and TCP/IP address: 1. The Gateway 3. 11 Utility Software provides access to the IP address of the MPC-ETN. Install the software from the accompanying CD. :\MPC SETUP KIT 311\Setup. exe Installation Wizard will now start, Press the NEXT button to continue. THOMSON TECHNOLOGY 9087A ­ 198 STREET, LANGLEY, BC CANADA V1M 3B1 TELEPHONE: (604) 888-3381 EMAIL: info@thomsontechnology. com www. thomsontechnology. com PM086 REV 1 08/08/28 th Quick Installation Guide for MPC-ETN Enter desired `User Name' and `Company Name', and then Press the NEXT button. Select desired `Destination Folder', and then Press the NEXT button. THOMSON TECHNOLOGY 9087A ­ 198 STREET, LANGLEY, BC CANADA V1M 3B1 TELEPHONE: (604) 888-3381 EMAIL: info@thomsontechnology. com www. thomsontechnology. com PM086 REV 1 08/08/28 th Quick Installation Guide for MPC-ETN Press the NEXT button. Mark both `MPC-ETN' and `MPC-STD' with a `check mark', and then Press the NEXT button. THOMSON TECHNOLOGY 9087A ­ 198 STREET, LANGLEY, BC CANADA V1M 3B1 TELEPHONE: (604) 888-3381 EMAIL: info@thomsontechnology. com www. thomsontechnology. com PM086 REV 1 08/08/28 th Quick Installation Guide for MPC-ETN Program is now installing onto your computer. Wait for installation to complete, then Press the OK button. Gateway 3. 11 Utility Software is now Complete. 2. Open the required template project (MEC20 or TSC800) using the Project->Open Project menu. Select `MPC-ETN' found in the `Product Selection' tree. Click the `Open Project' button found in the Tool Bar located at the bottom of the `Gateway' software window. THOMSON TECHNOLOGY 9087A ­ 198 STREET, LANGLEY, BC CANADA V1M 3B1 TELEPHONE: (604) 888-3381 EMAIL: info@thomsontechnology. com www. thomsontechnology. com PM086 REV 1 08/08/28 th Quick Installation Guide for MPC-ETN Select ET5MEC20-R2. prj for MEC20 communication or ET10TSC800-R2. prj for TSC800 communication, and then Press the OPEN button. 3. To change the default IP and Ethernet address Press the PLC2 button on the Gateway Utility Software toolbar. Click the Advanced button to open the IP edit dialog box. THOMSON TECHNOLOGY 9087A ­ 198 STREET, LANGLEY, BC CANADA V1M 3B1 TELEPHONE: (604) 888-3381 EMAIL: info@thomsontechnology. com www. thomsontechnology. com PM086 REV 1 08/08/28 th Quick Installation Guide for MPC-ETN Enter the required Modbus Node number (the default node is 1). Press the Extended Setup button for the TCP/IP setup. Enter the TCP/IP information and press the OK button. NOTE: · Your IT SUPPORT GROUP must assign a `Static IP Address' to the MPC-ETN. The `Static IP Address' is required so that the MPC-ETN device will work correctly on your Ethernet Network. 4. Connect the PC end of the programming cable to the PC and connect the MPC-COM1 end of the programming cable to the MPC-ETN COM1 port. 5. Press the Download button of the Gateway Utility Software toolbar. THOMSON TECHNOLOGY 9087A ­ 198 STREET, LANGLEY, BC CANADA V1M 3B1 TELEPHONE: (604) 888-3381 EMAIL: info@thomsontechnology. com www. thomsontechnology. com PM086 REV 1 08/08/28 th Quick Installation Guide for MPC-ETN Select the appropriate COM port from the combo dropdown list. If the light stops blinking before an upload or a download is conducted then the power to the MPC-ETN must be cycled to put it back into upload/download mode. Set-up complete. THOMSON TECHNOLOGY 9087A ­ 198 STREET, LANGLEY, BC CANADA V1M 3B1 TELEPHONE: (604) 888-3381 EMAIL: info@thomsontechnology. com www. thomsontechnology. com PM086 REV 1 08/08/28 th Quick Installation Guide for MPC-ETN Connections for Final Configuration: Connecting to MPC-ETN 1. Connect the RJ45 end of Cable 1 to the intended Thomson Technology controller. Connect the MPC-COM1 end of Cable 1 to the MPC-ETN port labeled COM1. Connect MPC-ETN to PC 1. Connect a customer supplied Ethernet cable to the Ethernet port of the MPC-ETN (not the Pass Through port). [. . . ] Open `Modscan32. exe' and follow the procedure below: Select `Connect' for the `Connection' drop down menu. Connect Using: `Remote Modbus TCP Server', Enter IT supplied `Static IP Address', Default listening port `502'. THOMSON TECHNOLOGY 9087A ­ 198 STREET, LANGLEY, BC CANADA V1M 3B1 TELEPHONE: (604) 888-3381 EMAIL: info@thomsontechnology. com www. thomsontechnology. com PM086 REV 1 08/08/28 th Quick Installation Guide for MPC-ETN For MEC20 ­ Enter Address: `1001' Length: `5' '03:HOLDING REGISTER' For TSC800 ­ Enter Address: `6001' Length: `5' '03:HOLDING REGISTER' NOTE: · When comm. /setup/configuration is correct the program will increment both counters (Number of Polls and Valid Slave Responses) at the same rate. You may notice that the two numbers are at a different value but both will count up at the same time. If there is any issues with comm. /setup/configuration, you may see the following messages o **Data Un-Initialized** o **Device NOT CONNECTED!** o **MODBUS Message TIME-OUT** o **MODBUS Exception Response from Slave Device** · THOMSON TECHNOLOGY 9087A ­ 198 STREET, LANGLEY, BC CANADA V1M 3B1 TELEPHONE: (604) 888-3381 EMAIL: info@thomsontechnology. com www. thomsontechnology. com PM086 REV 1 08/08/28 th [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE THOMSON MPC-ETN




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual THOMSON MPC-ETN will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.