User manual SIMRAD SP70 REV D
DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual SIMRAD SP70. We hope that this SIMRAD SP70 user guide will be useful to you.
You may also download the following manuals related to this product:
SIMRAD SP70 REV D (3104 ko)
SIMRAD SP70 MINI MANUAL REV D (525 ko)
Manual abstract: user guide SIMRAD SP70REV D
Detailed instructions for use are in the User's Guide.
[. . . ] Operator manual
SP70 Low frequency, long range fishery sonar
www. simrad. com
MAXIMIZING YOUR PERFORMANCE AT SEA
850-164186 / Rev. D
SP70 Low frequency, long range fishery sonar
Operator manual
WARNING
The sonar must never be powered up when the ship is in dry dock. To prevent inadvertent use of the sonar, pull out the mains plug on the Sonar Processor Unit whenever the vessel is in dry dock.
About this document
Rev Rev. D Date 25. 11. 04 Written by RBr Checked by SØJ Approved by OBG
Updated for software version 1. 2. X
© 2004 Simrad AS ISBN 82-8066-009-07 All rights reserved. No part of this work covered by the copyright hereon may be reproduced or otherwise copied without prior permission from Simrad AS. The information contained in this document is subject to change without prior notice. [. . . ] The menu allows you to change the transmit parameters.
Fish Tagging parameters
Tilt, page 154 Tx Power, page 160 Sector, page 146 Audio volume, page 99
The Frequency button is visible, but the function is unavailable. The Help button opens the on-line help.
Related topics
Fish Tagging, mode description, page 29
72
850-164186 / Rev. D
Menu description
Temporary menus
The Temporary menus are those selected from the active menus. They are also shown with vertical tabs on the right side of the menu, and can easily be selected by the trackball and the Select button. The Temporary menus must however be removed manually using the Close button in the bottom of menu. All Temporary menus have access to on-line help through a Help button.
Temporary menus
Cosmetics, page 74 Store/Recall, page 75 Test, page 76 Sort Modes, page 78
850-164186 / Rev. D
73
Simrad SP70
Cosmetics
The Cosmetics menu is activated by pressing the Cosmetics button in the Display menu. It provides access to various parameters controlling the appearance of the sonar picture. All the functions - except Track history - are on/off buttons.
Cosmetic parameters
Slant Range / True Range, page 147 Bearing Card, page 57 Compass Card, page 58 Distance Rings, page 57 VRM (Variable Range Marker), page 58 Bow Marker, page 59 Track History, page 156 Minute Marker, page 59 Wind Marker, page 57 Vertical Ring, page 58 Depth dividers, page 59
The Close button closes this menu. The Help button opens the on-line help.
74
850-164186 / Rev. D
Menu description
Store/Recall
The Store/Recall menu is activated by the Store/Recall button in the Setup menu. The Store/Recall menu is used to store single display pictures or a sequence or pictures. The stored pictures can easily be recalled for evaluation or comparing schools.
Store/Recall parameters
Store - This is the "record" button to start the storage sequence. Print - Allows you to print the stored picture to the default printer (if any). The following other parameters are available:
Store, page 152 Store Mode, page 152 Recall, page 139 Recall Mode, page 139
The Close button closes this menu. The Help button opens the on-line help.
850-164186 / Rev. D
75
Simrad SP70
System test
The System test menu is activated by the Test button in the Setup menu. The System test menu provides several test routines available to perform operational and functional tests. These tests are designed only to be carried out by qualified service engineers.
Test parameters
Test Configuration - This function is only to be activated by qualified service engineers. Test Function - This function is only to be activated by qualified service engineers. Toggle TxPower - This function is only to be activated by qualified service engineers. Test Beam - This function is only to be activated by qualified service engineers. Echo Level - This button provides a readout of the current noise in the waters surrounding the vessel. This noise is caused by air bubbels, water flow and mechnical disturbances from hull and engine. In order to obtain the besst possible sonar result, the noise level readout should be as close to 0. 0 dB as possible. Roll - This is not a button, it is a readout from the sensor of the actual roll value at the time of the last transmission. [. . . ] Use an Allen key to tighten up the screw until the motor brake is released. - Note that this item is not applicable on the SP75 Hull Unit!
4
850-164186 / Rev. D
179
Simrad SP70
5 6
Use the hand crank to hoist and lower the transducer. When finished, loosen the brake release screw to engage the motor brake. Remove the hand crank from the stub shaft, and mount it in its storage position in the Motor Control Unit. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE SIMRAD SP70
Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual SIMRAD SP70 will begin.