User manual MINOLTA SPAD-502 BROCHURE

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual MINOLTA SPAD-502. We hope that this MINOLTA SPAD-502 user guide will be useful to you.


MINOLTA SPAD-502 BROCHURE: Download the complete user guide (1360 Ko)

Manual abstract: user guide MINOLTA SPAD-502BROCHURE

Detailed instructions for use are in the User's Guide.

[. . . ] CHLOROPHYLL METER SPAD-502 A lightweight handheld meter for measuring the chlorophyll content of leaves without causing damage to plants. The SPAD-502 is a compact meter designed to help users improve crop quality and increase crop yield by providing an indication of the amount of chlorophyll present in plant leaves. [. . . ] One set of two AA-size alkaline-manganese batteries can provide approximately 20, 000 measurements. Small measuring area The measuring area is only 2 × 3mm, allowing measurements of even small leaves. A sliding depth stop is included for accurate positioning of sample leaves. High accuracy High measuring accuracy (± 1. 0 SPAD unit for rice-plant leaves) allows close examination of growing conditions. Data in memory can be recalled or deleted at a later time, and the average value of all data in memory can be automatically calculated. Reading checker A reading checker enables users to check that the SPAD502 is functioning correctly and providing accurate readings. Theory The SPAD-502 determines the relative amount of chlorophyll present by measuring the absorbance of the leaf in two wavelength regions. The graph at right shows the spectral absorbance of chlorophyll extracted from two leaf samples using 80% acetone. From the diagram, it can be seen that chlorophyll has absorbance peaks in the blue (400-500nm) and red (600-700nm) regions, with no transmittance in the near-infrared region. [. . . ] During the differentiation and formation of ears, a period of rapid plant development, the SPAD value fell to between 29 and 32, indicating that additional fertilizer was necessary. SPECIFICATIONS Type: Handheld meter for measuring chlorophyll using optical density difference at two wavelengths Measurement sample: Crop leaves Measurement system: Optical density difference at two wavelengths Measurement area: 2 × 3mm Light source: 2 LEDs (light-emitting diodes) Receptor: 1 SPD (silicon photodiode) Display: Measurement data: 3-digit LCD with decimal point Data number: 2-digit LCD Data memory: Space for 30 data sets Controls: Power switch, AVERAGE key, ALL DATA DELETE key, ONE DATA DELETE key, and DATA RECALL key Power source: 2 AA-size alkaline-manganese (1. 5V) batteries Battery line: More than 20, 000 measurements Minimum interval between measurements: Less than 2 seconds Accuracy: Within ± 1. 0 SPAD unit (at room conditions, SPAD value between 0 and 50) Repeatability: Within ± 0. 3 SPAD units (SPAD value between 0 and 50) Reproducibility: Within ± 0. 5 SPAD units (SPAD value between 0 and 50) Temperature drift: Less than ± 0. 4 SPAD units/°C Temperature range: Operation: 0 to 50°C; Storage: - 20 to +55°C Dimensions: 164 ×78 × 49mm (6-7/16 × 3-1/16 × 1-15/16 in. ) Weight: 225g (7-15/16 oz. ) (not including batteries) Other: Warning buzzer; User calibration function Specification subject to change without notice ©2003 KONICA MINOLTA SENSING, INC. 9242-4817-41 AHIDPK 13 Printed in Japan [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE MINOLTA SPAD-502




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual MINOLTA SPAD-502 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.