User manual MICROTEK GNC M ATX6000XY XXXX
DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual MICROTEK GNC M ATX6000XY XXXX. We hope that this MICROTEK GNC M ATX6000XY XXXX user guide will be useful to you.
Manual abstract: user guide MICROTEK GNC M ATX6000XY XXXX
Detailed instructions for use are in the User's Guide.
[. . . ] 1 Introduction
Congratulations on your purchase of the ArtixScan 6000XY scanner. The 42-bit highresolution ArtixScan 6000XY is specifically for graphic arts and imaging professionals. This manual will help you in the installation and operation of your scanner.
Specifications
Type Image Sensor Mechanical Resolution Optical Resolution Sample Depth Dynamic Range Scanning Area Desktop, XY technology scanner Tri-linear 8, 000 element CCD 6, 000 dpi 2, 000 dpi 14 bits per color 3. 7D Reflective 1 " x 1 " (305 mm x 432 mm) :2 7 Tr ansparency: 1 " x 1 " (305 mm x 432 mm) 2 7 15 scans per hour (6 cm x 7 cm, 250%, 300dpi, CMYK) SCSI-2 Cold Cathode Lamp Opera i g 61 - 80°F (16 - 27°C) tn: Storage: -10 - 55°F 10% - 85% 14" x 34" x 27. 5" (36 mm x 87 mm x 70 m 147 lb (67 kg) Opera i n 290 W to: Standby 200W : CSA, T U V, FCC class B, CF
Scanning Productivity Itr n e face Lamp Source Temperature
Humidity Dimensions Net W eight Pow er Consumption
Cert f c t o s iiain
ArtixScan 6000XY Installation and Operation Manual
1
2 Site Power and Working Space
This section describes the working conditions and working space for operating the ArtixScan 6000XY.
General Requirements
Before unpacking your scanner, make sure that the site where the scanner will be installed is big enough to allow for easier operation. · Make sure that the operating environment for the scanner is free of dust and other contaminants. [. . . ] Power is off.
When the push button is pressed, the scanner carriage starts to travel to the scanning lamp replacement position.
LED Indicator
This LED indicates the status of the scanner.
Green Blinking Green Red Off Scanner is ready for operation. Scanner is busy or during self-test Scanner malfunction Indicates the TMA is not closed, or the scanner carriage for the reflective materials is not in position.
ArtixScan 6000XY Installation and Operation Manual
11
Power up sequence
Follow the power up sequence below: 1. Turn on your scanner by pressing the Power Push button on the right corner. You will observe the following: 1) On the scanner panel, the lamp turns green while the Status lamp turns red for a few seconds. 2) The Status lamp blinks green, indicating system self-test is starting. 3) The Status lamp becomes a steady green, indicating that the scanner is ready for operation. If the lamp indicator remains red or blinking green, this indicates the scanner is faulty or not ready. Shutdown is performed by exiting the application and then turning off the main power switch.
Placing originals
Depending on the material you are scanning, you will be doing one of the following below: · Placing originals on the scan bed · Using customized masks · Using 35mm slide holder
Placing originals on the scan bed
For single originals: Tape the original to the scan bed. Align the top right corner of the original with the 0, 0 corner of the glass (which is at the lower right corner). When scanning a thick reflective original such as a book, you may scan with the Top Cover open.
12
ArtixScan 6000XY Installation and Operation Manual
For multiple originals: When prescanning a "batch" images, tape all to the scan bed, and then scan in a single pass. The originals must be of the same type (transparency or reflective), but can be different in size or media (transparency or negative). · Mount the second slide holder on the scanner next to the first holder. See the figure below.
The two guide-holes.
14
ArtixScan 6000XY Installation and Operation Manual
· Place the mask on the scan bed.
Place the mask.
The figure below shows the customized mask with cut windows for 5 transparencies.
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
1
9
8
7
6
5
4
3
2
0 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
0
7
6
5
4
User mask name
si ency em ul on si do r de w r n Tape t anspa
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
3
1
Do
not
cover
bar-code
Customized mask with cut windows fo 5 r t ansparencies. r
19
20
21
22
2
23
24
25
26
27
28
29
30
31
32
33
34
35
TR A N S P A R E N C Y S I E D
36
USER DEFINED MASK
37
38
39
Cat. 509D1L005
40
41
4
42
43
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
1
9
8
7
6
5
4
3
· Mount the mask without originals in the scanner with the transparency side facing up; insert the mask's registration holes into the registration pins of the scan bed.
ArtixScan 6000XY Installation and Operation Manual
2
0
43
42
41
40
39
38
37
36
35
34
33
32
31
30
29
28
27
26
25
24
23
22
21
20
19
15
Note: The 0, 0 corner of the mask is approximately above the 0, 0 corner of the scan bed. For the reflective material: · Tape the reflectives to the reflective side of the mask, according to your customized format. Taping the originals is similar to directly place your original on the scan bed. · To mount in the scanner, turn the mask over so that the transparency label of the mask faces up. Align and insert the mask registration holes into the registration pins of the glass.
Tr ansparency side
Transparency side
Align and insert the mask r g s ration holes. eit
Using the customized mask
(Note: This section should work with the software, so presently it is left blank. )
Using the slide holder
The slide holder can hold up to 20 pieces of 35mm slides. We recommend you insert your slides row by row, that means, when the first row is full, continue to the next row.
Insert t e s i e r by r h l d s ow ow.
16
ArtixScan 6000XY Installation and Operation Manual
Appendix A: Service and Maintenance
This appendix discusses regular maintenance which covers scanning lamp replacement and glass plate cleaning.
Lamp Replacement
Your ArtixScan 6000XY scanner consists of 3 scanning lamps: · One scanning lamp in the transparency scanning carriage (inside the scanner's top cover) · Two scanning lamps in the reflective scanning carriage In the following situations you should replace the scanning lamps: · The light level is low. This rule applies to both the transparency and reflective scanning lamps. [. . . ] · Make sure that a terminator is connected to the last device on the SCSI chain. If the scanner is at the last device, make sure that the terminator switch on the scanner is set to the ON position. · Maker sure that there is no other device use the same SCSI ID number. · If you have third-party SCSI check application, launch it and check if the scanner appears in the SCSI chain. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE MICROTEK GNC M ATX6000XY XXXX
Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual MICROTEK GNC M ATX6000XY XXXX will begin.