User manual LG LF53075032D

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual LG LF53075032D. We hope that this LG LF53075032D user guide will be useful to you.


LG LF53075032D : Download the complete user guide (2195 Ko)

Manual abstract: user guide LG LF53075032D

Detailed instructions for use are in the User's Guide.

[. . . ] For parts with this sign, • This sign is for displaying risks involving electric shock under certain conditions. user must read the manual carefully and follow instructions in order to avoid risks. LED FLAT LIGHT 53W/60W Advantages Replacing existing lighting devices with the LED FLAT LIGHT can reduce energy costs by 30% or more. Existing lamp LG FLAT 53W of planting 17 trees WARNING CAUTION ※ If used 12 hours each day for a year ※ Conversion constant 0. 573 kgCO2/Kwh, 3. 86kgCO2/tree) ● Violation of warnings may lead to serious injury or death. ● Violation of precautions may lead to light injury or product damage. User Manual 34% - 70% WARNING Product is heavy. [. . . ] Do not use the product if impurities are present in the product or if the product is submerged. • Risk of product malfunctioning. Converter < 600 x 600 Type > < 300 x 1200 Type > 1 Drill and prepare the ceiling so the hole is smaller than the product. 2 Connect the 3 product cables to the interior wiring of the building. For wire connectors, use standardized products. 3 Rotate the connected product by 20 degrees. • Make sure that all 4 sides of the product match the T-bar. Must fix the product properly on the ceiling. Product Size Must have at least two or more people working during installation. • Risk of product dropping and causing injury to the user. T: 596/620 M: 620 CAUTION Do not install where it may be exposed to direct sunlight, humidity, or dust. Alcohol Benzene T: 1256 M: 1270 T: 596/620 M: 620 94 T: 94/96 M: 96 T: 296 M: 310 Do not disassemble or arbitrarily remodel the product. (Underwater landscape, searchlight, fishing, events, etc. ) • Risk of fire and electric shocks. If the lamp turns off by itself, do not disassemble the product. • Risk of electric shock and product malfunctioning. Do not clean the product with inflammable substances such as alcohol, benzene, and acetone that may alter the surface. *Unit: mm T : T -BAR M : M-BAR 4 Place the horizontal product into the T-bar. 5 Ensure the inserted product is horizontal. 6 Once installation is complete, turn on the power switch to check it is operating properly. • After the installation is complete, remove the protective sheet. Check the following before requesting repair service 2. M-BAR • Make sure to turn the main power switch of the installation space before connection. (LIVE: BROWN, NEUTRAL: BLUE, P. E. : GREEN/YELLOW) • When this luminaire is connected to branch circuit, installation engineer must use the connector that is flame retardance of UL-94 V0 or higher. • Use woodscrews provided by LG Electronics. Model Information Category 3000K T-Bar M-Bar 4000K 600x600 Type 5000K T-Bar M-Bar T-Bar M-Bar 5700K T-Bar M-Bar 3000K T-Bar M-Bar 4000K 300x1200 Type 5000K T-Bar M-Bar T-Bar M-Bar 5700K T-Bar M-Bar 53W LF53073032*. C00***0 LF53173032*. C00***0 LF53074032*. C00***0 LF53174032*. C00***0 LF53075032*. C00***0 LF53175032*. C00***0 LF53075732*. C00***0 LF53175732*. C00***0 LF53175732*. C00***0 LF53173042*. C00***0 LF53074042*. C00***0 LF53174042*. C00***0 LF53075042*. C00***0 LF53175042*. C00***0 LF53075742*. C00***0 LF53175742*. C00***0 60W LF60074032*. D00***0 LF60174032*. D00***0 LF60075032*. D00***0 LF60175032*. D00***0 LF60075732*. D00***0 LF60175732*. D00***0 LF60074042*. D00***0 LF60174042*. D00***0 LF60075042*. D00***0 LF60175042*. D00***0 LF60075742*. D00***0 LF60175742*. D00***0 Symptom It won’t turn on. Check Check to see if the power is connected or Check to see if the dimming wires has short-circuited. Category Watts Light Color (CCT) Light Output (Lumens) 3000 3600 68 Color Accuracy (CRI) Beam Angle 53W 53. 0 4000 3800 72 5000 4000 76 5700 3900 74 80 82 T-Bar : 596(W) x 596(D) x 94(H) 620(W) x 620(D) x 96(H) M-Bar : 620(W) x 620(D) x 96(H) T-Bar : 296(W) x 1256(D) x 94(H) M-Bar : 310(W) x 1270(D) x 94(H) 5 AC 110 - 240 ~ 50 / 60 Single-Phase Three-Wire System 4000 4600 77 60W 60. 0 5000 4900 82 5700 4800 80 Unit W K Im Im/W LIVE NEUTRAL P. E. Interior wiring of the building Wire connectors 114 ˚(degrees) Product’s power cables 1 Drill and prepare the ceiling so that the hole is smaller than the product. 2 Connect the 3 product cables to the interior wiring of the building. [. . . ] (SOME STATES AND PROVINCES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS, SO THE ABOVE LIMITATION MAY NOT APPLY TOYOU. ) ※ This dimming terminal is for cable dimming control use (0-10V). ※ Please check the polarity of terminal as shown in the wiring diagram before connecting the dimming wires. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LG LF53075032D




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual LG LF53075032D will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.