User manual LG CS12AF

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual LG CS12AF. We hope that this LG CS12AF user guide will be useful to you.


LG CS12AF : Download the complete user guide (2692 Ko)

You may also download the following manuals related to this product:

   LG CS12AF (2893 ko)
   LG CS12AF (2456 ko)
   LG CS12AF (2510 ko)
   LG CS12AF (2454 ko)

Manual abstract: user guide LG CS12AF

Detailed instructions for use are in the User's Guide.

[. . . ] ENGLISH Visit us at http://www. lgservice. com ITALIANO LG LG Air Conditioner OWNER'S MANUAL Type : Wall Mounted ESPAOL FRANAIS DEUTSCH PORTUGUS NEDERLANDS POLSKI IMPORTANT Please read this owner's manual carefully and thoroughly before installing and operating your room air conditioner. Please retain this owner's manual for future reference after reading it thoroughly. MAGYAR Air Conditioner Owner's Manual TABLE OF CONTENTS A. Electrical Safety. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Temporary Use of an Adapter . . . . . . . . . . . . . . . 6 Temporary Use of an Extension Cord . . . 6 Symbols used in this Manual. . . . . . . . . . . . . . . . . 6 C. Product Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Indoor Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Operation Indication Lamps . . . . . . . . . . . . . . . . . . 7 Self-Diagnosis Function . . . . . . . . . . . . . . . . . . . . . . . . 7 D. [. . . ] Error code (10 digits) Self-Diagnosis Function Error Indicator : lights up Blue lamp and red lamp alternately Number of lamp's blink : indicate Error code Error code 01 02 03 05 06 10 12 Description Indoor ROOM themistor error (TH1) Indoor IN-PIPE thermistor error (TH1) Remote controller error Communcation error between in and out Indoor OUT-PIPE thermistor error (TH2) Indoor BLDC fan lock Indoor MID-PIPE thermistor error (TH3) Owner's Manual 7 Operating Instructions Operating Instructions How to insert the Batteries 1. Remove the battery cover by pulling it according to the arrow direction. Insert new batteries making sure that the (+) and (-) of battery are installed correctly. If the system is not to be used for a long time, remove the batteries to save their working life. If the display screen of remote controller starts fading, replace both of the batteries. Use 2 AAA(1. 5 volt) batteries. Wireless Remote Controller Maintenance 1. Signal transmitter & receiver should always be clean for proper communication. In case some other appliances also get operated with remote control, change their position or consult your serviceman. Operating Method 1. There should not be any blockage in between. 8 Air Conditioner Operating Instructions Wireless Remote Controller The controls will look like the following. Signal transmitter CANCEL ON OFF SET AUTO CLEAN CANCEL SET START/STOP BUTTON Used to turn off/on the unit. INDOOR FAN SPEED SELECTOR BUTTON Used to select fan speed in four steps low, medium, high and CHAOS. (It operates fan in super high speed) CHAOS SWING BUTTON Used to stop or start louver movement and set the desired up/down airflow direction. ON/OFF TIMER BUTTONS Used to set the time of starting and stopping operation. TIMER SET/CANCEL BUTTON Used to set and to cancel the timer operation. AIR CIRCULATION BUTTON Used to circulate the room air without cooling or heating. ENERGY-SAVING COOLING MODE BUTTON ROOM TEMPERATURE CHECKING BUTTON Used to check the room temperature. 2nd F BUTTON Used prior to using modes printed in blue at the bottom of buttons. AUTO CLEAN BUTTON Used to set auto clean mode. In some models this button has a 2nd function of display luminosity. ENGLISH Flip-up door (opened) Operation Mode Cooling Operation Auto Operation or Auto Changeover Healthy Dehumidification Operation Heating Operation Cooling Model( ), Heat Pump Model( ) NOTE To use the functions printed in blue at the bottom of the buttons press 2nd F button first and then the required function button. Pressing the 2nd F button activates the blue printed function of the respective button. To cancel the function press the 2nd F button again else it will automatically cancel if remains idle after 10 seconds. Owner's Manual 9 Operating Instructions Operation Mode 1 Press the START/STOP BUTTON to turn the unit on. The unit will respond with a beep. 1 3 4 ON 2 Open the door of the remote controller and press the operation mode button. Each time the button is pressed, the operation mode is shifted in the direction of the arrow. 2 Cooling Single : Auto Healthy Changeover Dehumidification Multi : Auto Operation Heating (Heat pump model only) 3 For cooling or heating operation set the desired indoor temperature by pressing the ROOM TEMPERATURE SETTING BUTTONS. For cooling the temperature can be set within 18C~30C and for heating the temperature range is 16C~30C. To raise the temperature To lower the temperature 4 Set the fan speed with the remote controller. [. . . ] When power regains after a failure this feature restore the previous operating condition and the air conditioner will run in the same settings. NOTE This feature is enabled by factory default setting, but you can disable it by pressing the ON/OFF button for 6 seconds. The display will blink 3~4 times. ON/OFF button Owner's Manual 15 Wired Remote Controller (Accessory) MODEL : PQRCVSA0 1 2 3 4 5 2 3 4 5 6 OPERATION INDICATION SCREEN SET TEMPERATURE BUTTON FAN SPEED BUTTON ON/OFF BUTTON OPRATION MODE SELECTION BUTTON RECEIVER Some products don't receive the wireless signals. 1 10 9 8 7 11 12 13 14 15 6 WIRELESS REMOTE CONTROLLER 7 8 9 10 AIR FLOW BUTTON SUBFUNCTION BUTTON FUNCTION SETTING BUTTON VENTILATION BUTTON 11 RESERVATION 12 UP, DOWN, LEFT, RIGHT BUTTON Please attach the inform label inside of the door. Please choose proper language depend on your country. To check the indoor temperature, press button. 13 ROOM TEMPERATURE BUTTON 14 SETTING/CANCEL BUTTON 15 EXIT BUTTON Some functions may not be operated and displayed depending on the product type. Read Remote Controller's Owner's manual for detail operation method. 16 Air Conditioner Maintenance and Service Maintenance and Service Before performing any maintenance, turn off the main power to the system, disconnect the circuit breaker and unplug the power cord. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LG CS12AF




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual LG CS12AF will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.