User manual JBSYSTEMS MINI LED MANAGER V 1.1

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual JBSYSTEMS MINI LED MANAGER. We hope that this JBSYSTEMS MINI LED MANAGER user guide will be useful to you.


JBSYSTEMS MINI LED MANAGER V 1.1: Download the complete user guide (2531 Ko)

Manual abstract: user guide JBSYSTEMS MINI LED MANAGERV 1.1

Detailed instructions for use are in the User's Guide.

[. . . ] The exclamation point within the equilateral triangle is intended to alert the user to the presence of important operation and maintenance (servicing) instructions in the literature accompanying this appliance. This symbol means: indoor use only This symbol means: Read instructions This symbol means: Lamp Control Gear To prevent fire or shock hazard, do not expose this appliance to rain or moisture. To avoid condensation to be formed inside, allow the unit to adapt to the surrounding temperatures when bringing it into a warm room after transport. Condense sometimes prevents the unit from working at full performance or may even cause damages. [. . . ] Important: This device left our factory in perfect condition and well packaged. It is absolutely necessary for the user to strictly follow the safety instructions and warnings in this user manual. The dealer will not accept responsibility for any resulting defects or problems caused by disregarding this user manual. To protect the environment, please try to recycle the packing material as much as possible. Do not use volatile liquids such as benzene or thinner which will damage the unit. Since this unit uses a cooling fan, the interior of the device should be cleaned annually using a vacuum cleaner or air-jet. This input receives instructions from a DMX-controller or from another Mini Led Manager when used in master/slave mode. DMX OUTPUT: 3pin female XLR-connector used to connect the Mini Led Manager with the next DMX appliance in the chain or with another Mini Led Manager when used in master/slave mode. The mini LED Manager can also be used as controller for other LED projectors like for example "LED PAR56/64" 4. DIP SWITCHES: when used in DMX mode (DIP10 = OFF) you can set the DMX-starting address of the unit. When used in stand-alone mode (master, DIP10 = ON), you can use the DIP-switches to set different pre-programmed options. AUTO DMX ADDRESS BUTTON: see further to learn how to set the DMX address easily. OUTPUT CABLE: used to connect different 24Vdc common anode LED projectors. You can use the supplied conversion cable to easily connect different projectors. OUTPUT MONITOR: you can check the separate output state of the 3 colors (red, green and blue) 9. This external switch can be used to switch the general output of the Mini LED Manager on/off. (external blackout) See further for more information on how to connect the analog switch. MAINS FUSE: Always replace this fuse with a fuse that has the same characteristics!The first 9 DIP-switches correspond to a certain DMX-value: DIP #1 #2 #3 #4 #5 #6 #7 #8 #9 Value 1 2 4 8 16 32 64 128 256 You can combine the values of these switches to obtain any starting address between 1 and 512: Begin address = 01 switch 1=ON values: 1 Begin address = 05 switch 1+3=ON values: 1+4 = 5 Begin address = 09 switch 1+4=ON values: 1+8 = 9 Begin address = 13 switch 1+3+4=ON values: 1+4+8 = 13 . Begin address = 62 switch 2+3+4+5+6=ON values: 2+4+8+16+32 = 62 DIP10 = ON Master operation (stand-alone) Use the dipswitches 1~9 to set the mode, speed, patterns, fixed color color. The electrical installation should be carried out by qualified personal only, according to the regulations for electrical and mechanical safety in your country. How to connect the LED-projectors to the output of the unit: Important: Switch the Mini Led Manager OFF before you install the LED-projectors! [. . . ] ) you can set the DMX addresses of all units in the DMX-chain just by the push of a button. Switch the unit with the free DMX-input connector to master, the other units are automatically switched as slaves. Electrical installation in Master/slave-mode with the LEDCON-02 (or LEDCON-01) remote: You need to "daisy chain" the DMX in/outputs of 1 or more units with the output of the LEDCON-02 remote using a good quality balanced cable Starting address of each individual unit, this will be done for you!Set the DMX-channel, that you want to assign as DMX-start address on your mini LED Manager, to maximum (value 255) Press the "Auto DMX address" button (6) on the first mini LED Manager in the chain for about 5seconds. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE JBSYSTEMS MINI LED MANAGER




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual JBSYSTEMS MINI LED MANAGER will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.