User manual JBSYSTEMS LED POWER BANK V 1.0
DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual JBSYSTEMS LED POWER BANK. We hope that this JBSYSTEMS LED POWER BANK user guide will be useful to you.
You may also download the following manuals related to this product:
JBSYSTEMS LED POWER BANK V 1.1 (2360 ko)
Manual abstract: user guide JBSYSTEMS LED POWER BANKV 1.0
Detailed instructions for use are in the User's Guide.
[. . . ] Ver 1, 0 (firmware V12)
USER MANUAL
T
ABLE OF CONTENTS
TABLE OF CONTENTS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . I. PART 1 PRODUCT (GENERAL). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.
1. 1--PRODUCT INTRODUCTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2. 1. 2--PRODUCT FEATURES. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2. 1. 3--TECHNICAL SPECIFICATIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3. [. . . ] 1, 13, 25, 37. . . ) Each DMX Address may be used as many times as required. ID Address should be set in the Settings menu on each unit in ascending values (i. e. ID Address should be set in the Settings menu on each unit in ascending values (i. e. When using the PIX CONTROLLER with the fixtures there is no need to set the DMX address. When using the Effect programs it is important to set the Range of fixtures in the Settings menu of the PIX CONTROLLER.
Example:
ID Addr. 1 ID Addr. 2 ID Addr. 3 ID Addr. 4
CONTROLLER
MOD E
SETU P
UP
DOW N
In the figure above the PIX controller is connected in series to 4 units with corresponding ID addresses from 1 to 4. In order to activate the Effect programs in the PIX CONTROLLER, the Range must be set to 004 in the Settings menu of the PIX CONTROLLER.
2 INSTALLATION
11
2007. 9. 8
2. 5-2 STANDARD BLOCK APPLICATION
Connect the fixtures to the PIX CONTROLLER in series in the direction that is required. ID Address should be set in the Settings menu on each unit in ascending values (i. e. When using the PIX CONTROLLER with the fixtures there is no need to set the DMX address. When using the Effect programs it is important to set the Range of fixtures in the Settings menu of the PiX CONTROLLER.
Example:
ID Addr. 1 ID Addr. 2 ID Addr. 3
ID Addr. 4
ID Addr. 5
ID Addr. 6
ID Addr. 7
ID Addr. 8
ID Addr. 9
CONTROLLER
MOD E
SETU P
UP
DO WN
In the figure above the PiX controller is connected in series to 9 units with corresponding ID addresses from 1 to 9. In order to activate the Effect programs in the PIX CONTROLLER, the Range must be set to 009 in the Settings menu of the PIX CONTROLLER. (Note: it is possible to create different kinds of effects by changing the direction and position of ID Addresses)
2 INSTALLATION
12
2007. 9. 8
2. 5-3 REPEAT ROW BLOCK APPLICATION
Connect the fixtures to the PIX CONTROLLER in series. ID Address should be set in the Settings menu on each unit in ascending order with each row repeated (Not required for Wash programs). When using the PRO-a CONTROLLER with the fixtures there is no need to set the DMX address. When using the Effect programs it is important to set the Range of fixtures in the Settings menu of the PRO-a CONTROLLER.
Example:
ID Addr. 1 ID Addr. 2 ID Addr. 3
ID Addr. 1
ID Addr. 2
ID Addr. 3
ID Addr. 1
ID Addr. 2
ID Addr. 3
CONTROLLER
MOD E
SETU P
UP
DO WN
In the figure above the PIX controller is connected in series to 9 fixtures with each row comprising of 3 fixtures with corresponding ID addresses from 1 to 3. Each row is repeated so that the ID addresses appear the same was as the first row. In order to activate the Effect programs in the PIX CONTROLLER, the Range must be set to 003 in the Settings menu of the PIX CONTROLLER.
2 INSTALLATION
13
2007. 9. 8
2. 6
OPERATION: DMX512 Vs PiX CONTROLLER
OPERATION WITH A DMX512 CONTROLLER
AVAILABLE FUNCTIONS
BENEFITS
DRAWBACKS
DMX512 ADDRESS ID ADDRESS
X
Basic WASH Programming
X
Advanced WASH & EFFECT programming
No need to set up DMX Address or ID Address
Must locate previosly stored DMX Address
DMX512 ADDRESS ID ADDRESS
Units are fully controlled from DMX512 controller
X X
Programming requires many DMX channels No auto programs
DMX512 ADDRESS ID ADDRESS
Basic WASH programming & ADAS
DMX Address ID address allows for less DMX channels when programming* ADAS User can switch be tween ADAS & real DMX address Advanced fixture mapping
No auto programs All ID addresses must be set
DMX512 ADDRESS ID ADDRESS
Advanced WASH & EFFECT programming & ADAS
No auto programs All ID addressesmust be set
OPERATION WITH THE PiX CONTROLLER
AVAILABLE FUNCTIONS
BENEFITS
DRAWBACKS
DMX512 ADDRESS ID ADDRESS
X X
Play WASH auto programs, Basic CUSTOM programming & Schedule play Play WASH auto programs, Basic CUSTOM programming & Schedule play Play WASH & EFFECT auto programs, Advanced CUSTOM programming & Schedule play
No need to set up DMX Address or ID Address
Only control of all units at the same time
DMX512 ADDRESS ID ADDRESS
DMX address not used
Only control of all units at the same time
X X
DMX512 ADDRESS ID ADDRESS
DMX Address not used Control speed and time of all WASH & EFFECT programs Create powerful CUSTOM programs Schedule play Trigger auto programs with DMX IN DMX Address not used Control speed and time of all WASH & EFFECT programs Create powerful CUSTOM programs Schedule play Trigger auto programs with DMX IN
All ID Addresses must be set
DMX512 ADDRESS ID ADDRESS
Play WASH & EFFECT auto programs, Advanced CUSTOM programming & Schedule play
All ID Addresses must be set
2 INSTALLATION
14
2007. 9. 8
3
DISPLAY PANEL OPERATION
3. 1 3. 2 3. 3 3. 4 3. 5 3. 6 3. 7 3. 8
BASIC MENU CREATING A STATIC COLOR DMX512 SETTINGS ACTIVATING AN AUTO PROGRAM CHANGING THE SETTINGS A CTIVATE THE PASSWORD POWER ON/OFF
3 DISPLAY PANEL OPERATION
15
2007. 9. 8
3. 1
BASIC
The LED fixture is mounted with a LCD display and 4 control buttons.
SET
UP
DOWN
EXIT
enter the currently selected menu or confirm the current function value scroll 'UP' through the menu list or increase the value of the current function scroll 'DOWN' through the menu list or decrease the value of the current function exit from the current menu or function
3 DISPLAY PANEL OPERATION
16
2007. 9. 8
3. 2
MENU
MENU
Static color Dimmer Red Green Blue Color macros Strobe Dimmer Red Green Blue Colormacros Strobe 0 0 0 0 0 0 255 255 255 255 255 255
DMX512
Address Personality
Address 1 STAGE 1 STAGE 2 ARC 1
512
Auto program
Auto Auto Auto Auto Auto Auto Auto Auto
1 2 3 4 5 6 7 8
Set ti n gs
ID address
ID address 001 066
ID ON/OFF
ID ON/OFF
RAS ON/OFF
RAS ON/OFF ADAS ON/OFF ADAS fader no 01 244 Copy ON/OFF Reset confirm
ADAS ON/OFF
ADAS fader no
Copy ON/OFF
R e se t to Factory settings
MENU
Passw ord
Password ON/OFF
Password ON/OFF Set Password
Set password
3 DISPLAY PANEL OPERATION
17
2007. 9. 8
3. 3
CREATING A STATIC COLOR
MENU
Static color Dimmer Red Green Blue Color macros Strobe Dimmer Red Green Blue Colormacros Strobe 0 0 0 0 0 0 255 255 255 255 255 255
Static colour Combine RED, GREEN and BLUE to create an infinite range of colors (0-255) Enter Color macros allow to choose 18 color macros Set value of dimmer (0-255) Set the value of the strobe (0-20Hz)
3. 4
DMX512 SETTINGS
MENU
DMX512 Address Personality Address 1 STAGE 1 STAGE 2 ARC 1 512
DMX512 address Enter the DMX address mode to set the DMX address Activate control from outside source by activating ON Enter Personality mode to choose DMX mode: STAGE 1 ARC 1
, STAGE 2
or
3 DISPLAY PANEL OPERATION
18
2007. 9. 8
3. 5
ACTIVATING AN AUTO PROGRAM
MENU
Auto program Auto Auto Auto Auto Auto Auto Auto Auto 1 2 3 4 5 6 7 8
Auto Program Select the target Auto mode and press Set to display
3. 6
CHANGING THE SETTINGS
MENU
Set ti n gs ID address ID address 001 066 ID ON/OFF
ID ON/OFF
RAS ON/OFF
RAS ON/OFF ADAS ON/OFF ADAS fader no 01 244 Copy ON/OFF Reset confirm
ADAS ON/OFF
ADAS fader no
Copy ON/OFF
R e se t to Factory settings
Settings Enter the ID Address to set the ID address for the unit Enter ID ON/OFF in order to allow/disallow ID address function from the DMX512 controller RAS ON/OFF reserve for future use. In ADAS ON/OFF select allow/disallow Automatic DMX512 Addressing System (ADAS) Enter the ADAS fader no to set the number of channel faders in each layer of the controller In the Copy ON/OFF menu select whether to allow copy of DMX and ID address to unit. Enter the Reset to Factory Settings in order to reset to default factory settings.
3 DISPLAY PANEL OPERATION
19
2007. 9. 8
3. 7
A CTIVATE THE PASSWORD
MENU
Passw ord O N / OF F Set Password Password ON/OFF Password
Enter the
Password mode to set password YES/NO
When password is activated, display will demand password each time the fixture is powered on. Input an 8 digit password and then press SET to confirm NOTE: In the event that the password is forgotten. UP > DOWN > UP > DOWN > UP > UP > DOWN > DOWN
3. 8
POWER ON/OFF
TURN OFF When display shows MENU , hold down the EXIT key for 3 seconds to turn off power. TURN ON When display is off, hold down the EXIT key for 3 seconds to turn on power.
3 DISPLAY PANEL OPERATION
20
2007. 9. 8
4
USING A DMX512 CONTROLLER
4. 1 4. 2 4. 3 4. 4 BASIC ADDRESSING CHANNEL ASSIGNMENT BASIC INSTRUCTIONS FOR DMX512 OPERATION PROGRAMMING WITH A DMX512 CONTROLLER: EXAMPLES
4 USING A DMX512 CONTROLLER
21
2007. 9. 8
4. 1
BASIC ADDRESSING
Connect all of the units in series using standard DMX512 signal cable or the IP65 rated cable provided. It is possible to have the same DMX address or independent addresses for each fixture.
4. 2
CHANNEL ASSIGNMENT
Note:
This product has three DMX512 channel configurations (STAGE 1 , STAGE 2 & ARC 1). [. . . ] 1) to select NO GREEN for all MODULES (ID Add. 1) to select NO BLUE for all MODULES (ID Add. 1) to select DMX mode 1 to select ID Add: 1 to select NO RED for all MODULES (ID Add. 2) to select NO GREEN for all MODULES (ID Add. 2) to select BLUE for all MODULES (ID Add. 2) to select DMX mode 1 to select ID Add: 2 to select NO GREEN for all MODULES (ID Add. 1 & ID Add. 2) to select GREEN for all MODULES (ID Add. 1 & ID Add. 2) to select NO GREEN for all MODULES (ID Add. 1 & ID Add. 2) to select DMX mode 2 to select all ID Addresses to select OFF for MODULE #1 (ID Add. 2) to select OFF for MODULE #3 (ID Add. 1) to select DMX mode 2 to select ID Add: 2 to select RED for MODULE #1 (ID Add. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE JBSYSTEMS LED POWER BANK