User manual JBSYSTEMS LED EXPO BANK V 1.0

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual JBSYSTEMS LED EXPO BANK. We hope that this JBSYSTEMS LED EXPO BANK user guide will be useful to you.


JBSYSTEMS LED EXPO BANK V 1.0: Download the complete user guide (3313 Ko)

Manual abstract: user guide JBSYSTEMS LED EXPO BANKV 1.0

Detailed instructions for use are in the User's Guide.

[. . . ] 1. 4--PHOTOMETRIC DATA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3. 1. 5--SAFETY WARNING. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3. PART 2 INSTALLATION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4. 2. 1--MOUNTING. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4. 2. 2--POWER CONNECTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2. 3--SETTING UP WITH A DMX512 CONTROLLER. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5. 2. 3-1--DMX512 ADDRESSING WITHOUT ID ADDRESSING. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5. [. . . ] 14. 1 1. 1 PRODUCT (GENERAL) PRODUCT INTRODUCTION This product is designed for indoor or outdoor use. Suitable applications include wash or effect lighting for architectural, stage or nightclub applications. This product can also be installed for use in signage and advertising using the dynamic functions available with DMX512 control. Direct input of DMX512 signal allows the units to be controlled from any DMX512 controller. This product can be operated as a single unit or in multiple units for large applications. 1. 2 PRODUCT FEATURES LED FIXTURE * * * * * * * * * RGB Dimmer 0-100% Strobe IP65 protection rating LCD display Display control 'lock-out' Direct DMX512 input Independent ID address Lightweight aluminium casing Different white colors setting 1 PRODUCT(GENERAL) 1 2008. 9. 19 1. 3 TECHNICAL SPECIFICATIONS LED MODULE LED MODULE: Voltage Rated Power IP LED/Unit Output/LED 100~240V. . . 50/60Hz 80W IP65 protection rating 54pcs (42 x White / 12 x Amber) 1W ~40 Environment Temperature -20 Cooling Dimensions Weight Direct air convection 380 x 200 x 190mm 8Kg 190mm 380mm 200mm 1 PRODUCT(GENERAL) 2 2008. 9. 19 1. 4 WHITE 3 2 1 0 1 2 3 PHOTOMETRIC DATA AMBER 3338 900 410 247 166 LUX 1261 361 155 90 62 LUX 2 4 6 8 10Distance(m) 3 2 1 0 1 2 3 15 2 4 6 8 10Distance(m) WHITE+AMBER 4795 1270 567 331 226 LUX 3 2 1 0 1 2 3 2 4 6 8 10Distance(m) 1. 5 SAFETY WARNING IMPORTANT ALWAYS READ THE USER MANUAL BEFORE OPERATION. PLEASE CONFIRM THAT THE POWER SUPPLY STATED ON THE PRODUCT IS THE SAME AS THE MAINS POWER SUPPLY IN YOUR AREA. This product must be installed by a qualified professional. A minimum distance of 0. 5m must be maintained between the equipment and combustible surface. DO NOT stand close to the equipment and stare directly into the LED light source. Always make sure that the supporting structure is solid and can support the combined weight of the products. Do not touch the power cables if your hands are wet. ATTENTION This product left the place of manufacture in perfect condition. In order to maintain this condition and for safe operation, the user must always follow the instructions and safety warnings described in this user manual. Make sure that all parts of the equipment are kept clean and free of dust. Always make sure that the power connections are connected correct and secure. If there is any malfunction of the equipment, contact your distributor immediately. When transferring the product, it is advisable to use the original packaging in which the product left the factory. Shields, lenses or ultraviolet screens shall be changed if they have become damaged to such an extent that their effectiveness is impaired. The lamp (LED) shall be changed if it has become damaged or thermally deformed. 1 PRODUCT(GENERAL) 15 3 2008. 9. 19 15 2 2. 1 INSTALLATION MOUNTING HANGING The LEDbloc can be mounted in a hanging position using the supporting bracket. The bracket should be secured to the mounting truss or structure using a standard mounting clamp. Please note that when hanging the unit a safety cable should also be used. UPRIGHT The LEDbloc can be mounted in an upright or sitting position using the supporting brackets. The LED MODULE can be mounted at any angle and in any position. It is possible to further adjust the angle of the LED MODULE using the two adjustment knobs located on the side of the fixture. 2. 2 POWER CONNECTIONS @ 220V: 35 units may be connected in series @120V: 15 units may be connected in series Note: As this fixture's DMX signal cable connection is Parallel connection, so if over 20 units to be connected, then a DMX signal amplifier is needed. 2 INSTALLATION 4 2008. 9. 19 2. 3 SETTING UP WITH A DMX512 CONTROLLER 2. 3-1 DMX512 ADDRESSING WITHOUT ID ADDRESSING (STUDIO 2 MODE) Connect the DMX512 controller to the units in series. [. . . ] On successful uploading of the custom programs the MASTER and SLAVE units will display WHITE. In order to reset custom modes to default values select PESET Parameter . Enter ID ON/OFF in order to allow/disallow ID address function from the DMX512 controller. 3. 9 MENU A CTIVATE THE PASSWORD KEYLOCK ON OFF KEYLOCK Enter the KEYLOCK mode to select whether the access password is on or off. In order to enter access password it is necessary to first press SET . [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE JBSYSTEMS LED EXPO BANK




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual JBSYSTEMS LED EXPO BANK will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.