User manual INTERMATIC 158SS11365

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual INTERMATIC 158SS11365. We hope that this INTERMATIC 158SS11365 user guide will be useful to you.


INTERMATIC 158SS11365 : Download the complete user guide (661 Ko)

Manual abstract: user guide INTERMATIC 158SS11365

Detailed instructions for use are in the User's Guide.

[. . . ] Place battery in holder with "+" end towards front of timer. Battery Holder MO ON Wiring diagram, 2 switch installation (3-way): MODE ON/OFF EVENT RESET DAY H+ M+ DAY H+ M+ 4b BLACK LINE TIMER JUMPER BLUE LOAD 2 5 NEUTRAL COMMON RED 3-WAY SWITCH Installations including a Dimmer: · The load size and type must not exceed the rating of the dimmer. (Typically 600 watts, 120 VAC, 60 Hz, incandescent lamps only. ) · If the dimmer is placed in it's `OFF' position, the timer cannot operate the lights. · If the dimmer is set too low, the lights may not turn back on under timer control. [. . . ] The installation instructions on this page are for replacing a light switch (or 3-way light switch) with the timer. See "Other Installations" on the next page for wiring diagrams for new construction, switching from 3 or more locations, or using the timer with a dimmer. Wiring diagram, 2 switch installation (3-way) using a single pole remote switch: LOAD BLUE BLACK LINE TIMER RED SINGLE POLE SWITCH NEUTRAL LINE BLACK TIMER RED (Capped, Not Connected) BLUE DIMMER DAY H+ M+ NEUTRAL Multi-switch installation using a dimmer : A 3-way dimmer should not be used. If a multi-switch installation is required, use the following diagram. Installation Instructions - Single Switch or 3-way - to replace an existing switch: 1. TURN OFF POWER by REMOVING FUSE or turning the CIRCUIT BREAKER OFF. BLACK WIRE MODE MODE button ON/OFF EVENT RESET 7/16" DAY MODE H+ M+ Trim building wires bare to 7/16". Connect one of the building wires to the black wire from the timer, using the wire nuts provided. BE SURE THAT ALL THE WIRE NUTS ARE SECURE. Push and release to change the mode (upper line of the display). AUTO RAND mode - Programmed ON/OFF times work and are randomly offset up to 15 minutes. The Mode button skips the AUTO modes if the time of day and/or the ON/OFF times have not been set. Wiring diagram, 3 switch installation: LIGHT For 3 or more switch operation, AN ADDITIONAL WIRE MUST BE ADDED between the load and the timer. The jumper wire is not required for these applications. ADDITIONAL WIRE BLUE BLACK LINE TIMER RED TWO 3-WAY SWITCHES NEUTRAL LINE LOAD BLACK TIMER BLUE DIMMER RED REMOTE SWITCH NEUTRAL BLUE WIRE RED WIRE (Capped, Not Connected) DAY button MODE ON/OFF EVENT RESET 3-way switch: (See "Other Installations" to use a dimmer or if switching from 3 or more locations) 3a. One of the wires is "common" (the terminal has a different colored screw or there are markings on the old switch). Connect the other two wires to the Blue and Red wires from the timer (it doesn't matter which goes to which. ) RED WIRE COMMON MOVE BLUE WIRE JUMPER WIRE TO OTHER TERMINAL REMOTE WIRE FROM IF THIS 3-WAY "COMMON" OF SWITCH SWITCH OLD SWITCH DOES NOT TURN LIGHT BLACK WIRE ON 3b. Release battery holder with flat screwdriver at notch (6a) and pull straight out. Pull at notch at top edge to remove the clear/cover switch so you can use the programming buttons. To stop the flashing display and turn switch to OFF: Push RESET button; Push MODE so CLK is displayed at the upper left; push H+ to stop the flashing display; push MODE twice so MAN is displayed at the upper right; push ON/OFF EVENT so display at upper right says OFF (you may hear the timer motor run and a clicking sound). Return the power to the circuit at the 6a service panel. MAN AM MO ON MODE ON/OFF EVENT RESET DAY H+ M+ M+ Works in CLK and PGM modes. If you pass the correct minute, push and hold to cycle around again. ON/OFF/EVENT button MODE ON/OFF EVENT RESET DAY H+ M+ ON/OFF EVENT DAY H+ M+ Function depends on the mode: CLK mode - ON/OFF EVENT button does nothing. PGM mode - Switches in order through the 12 programmable events 1 ON, 1 OFF, 2 ON, 2 OFF, 3 ON, 3 OFF, 4 ON, 4 OFF, 5 ON, 5 OFF, 6 ON, and 6 OFF. 2a CLK Load state doesn't match programmed state immediately after programming the time or schedule. Timer does not "catch up" to the programmed load state. The load will remain in it's state prior to entering the PGM mode. The timer will begin following the scheduled program at the next contrary ON/OFF time. Mechanism is inoperative. Battery Holder Battery Replacement The 1. 5 VOLT alkaline battery should operate your timer for 11/2 years or more under typical conditions. High or low temperature or frequent use of the manual pushbutton or the 3-way switch will reduce the battery life. [. . . ] Push and release the clear cover/switch (area over buttons) to switch ON or OFF. Or switch ON and OFF using the remote switch(es) in multi-switch installations. · · · · Works in AUTO, AUTO RAND or MAN modes. The program in AUTO or AUTO RAND remains; it automatically switches ON or OFF at next programmed time. FULL ONE YEAR WARRANTY If within one (1) year from date of purchase, this product fails due to a defect in materials or workmanship, Intermatic Incorporated will repair or replace it free of charge. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE INTERMATIC 158SS11365




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual INTERMATIC 158SS11365 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.