User manual INTERMATIC 158PG11842-1

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual INTERMATIC 158PG11842-1. We hope that this INTERMATIC 158PG11842-1 user guide will be useful to you.


INTERMATIC 158PG11842-1 : Download the complete user guide (3460 Ko)

Manual abstract: user guide INTERMATIC 158PG11842-1

Detailed instructions for use are in the User's Guide.

[. . . ] A form C relay for remote alarm indication, audible trouble alarm with test and silence switch are also standard equipment. The system is comprised of three sections; outer housing, cover plate and inner module. Each section is engineered to make the installer/service technician's task as easy as possible. Outer Housing - Metal housing measuring 20" wide x 16" high x 6" deep. [. . . ] If the voltage or the number of conductors does not agree with the information supplied with the Surge Protection Device, contact your supplier. If you have questions about the proper use of this unit for your application, contact Intermatic at the numbers listed under TECHNICAL ASSISTANCE on page 5 of this publication. PG60 - PG80 - PG100 Series with cover plate removed. Unit in position to be installed at the top of panelboard. FRONT Wire Pass-through area AC Voltage wiring area Wire Passthrough area 5. 75" 6. 0" Low voltage alarm contact wiring area REAR 3. 438" 1. 980" 9. 195" 20. 0" 3. 438" Table 1 INSTALLATION INSTRUCTIONS and OPERATIONS MANUAL 2 PG60-80- Figure 1 120/240 VAC Single Phase PG60-240-2S PG80-240-2S PG100-240-2S L1 L2 N G INSTALLATION (above panelboard) 1. SELECT the location where the Surge Protection Device (SPD) will be mounted, above or below the electric panel. Position the SPD adjacent to the electric panel with the bus bars pointed toward the panel. NOTE: If the SPD is mounted below the electric panel, the labels on the inner housing will be inverted. Refer to INVERTED INSTALLATION section below for information regarding the inverted installation. Align the SPD to allow 1/16" between the SPD cover plate and the cover of the panelboard. The SPD should be secured to a flat vertical surface that can support the weight of the device. Temporarily fasten the SPD to the vertical surface and mark the location where a hole for the collar or conduit will enter. Refer to Table 1 for acceptable locations on the bottom of the Outer Housing that can be drilled for wire entry. Keep all leads as short and straight as possible, avoiding sharp 90 degree bends. 10 AWG 30 AMP 8 AWG 40 AMP 6 AWG 50 AMP 4 AWG 60 AMP 2 AWG 80 AMP Table 2 INVERTED INSTALLATION (under panelboard) 1. SELECT the location where the Surge Protection Device (SPD) will be mounted below the electric panel. Position the SPD adjacent to the electric panel with the bus bars pointed toward the panel. Align the SPD to allow 1/16" between the SPD cover Plate and the cover of the panelboard. The SPD should be secured to a flat vertical surface that can support the weight of the device. ALARM RELAY CONNECTIONS Violet - n/c Brown - c Orange - n/o Normal operating condition - relay energized Violet - n/c Brown - c 3. Temporarily fasten the SPD to the vertical surface and mark the Orange - n/o location where a hole for the collar or conduit will enter. Refer to Table Alarm condition - relay not energized 1 for acceptable locations on the bottom of the Outer Housing that can be drilled for wire entry. Note that wiring for the remote monitoring relay Figure 6 enters separate from the AC power leads. Remove the SPD unit and drill a hole of sufficient size to accept the collar or conduit connector. ALARM RELAY SPECIFICATIONS Refer to Table 2 for suggested collar or conduit sizes. [. . . ] Check all PROTECTION STATUS Line indicator lights for proper illumination. (a) Common to Normally Open = greater than 10 M ohms, (b) Common to Normally Closed = 0 ohms. Audible alarm should sound, the Red Alarm Indicator LED should be ON and the alarm relay outputs should reverse state. The ALARM SWITCH should be in the NORMAL position for standard operating conditions. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE INTERMATIC 158PG11842-1




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual INTERMATIC 158PG11842-1 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.