User manual INTELLISENSE FG-1008

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual INTELLISENSE FG-1008. We hope that this INTELLISENSE FG-1008 user guide will be useful to you.


INTELLISENSE FG-1008 : Download the complete user guide (604 Ko)

Manual abstract: user guide INTELLISENSE FG-1008

Detailed instructions for use are in the User's Guide.

[. . . ] · If the magnetic contact is enabled, the glassbreak housing must be mounted less than 1" (2. 5 cm) from the magnet housing. The glassbreak detector and magnet housings must be aligned and mounted parallel to each other. · Magnetically susceptible material will affect the range of the contact gap. [. . . ] ) Remove breakout tab and use an industry standard 4" (10 cm) tie wrap if a strain relief is required. Secure the mounting plate and magnet housing with #6 (M 3. 5) screws (not provided). Route the wire through the wire entry hole in the PCB housing and reconnect the housing to the mounting plate. Replace front cover. Figure 4a Routing the wires through the mounting plate Back view of mounting plate 3 Figure 4b Align MAGNET and "SWITCH" Mount the PCB housing and magnet housing no more than 1" (2. 5 cm) apart. Front view of mounting plate "SWITCH" location indicator MAGNET Breakout tab Wire entry hole Route wire through wiring channel and wire entry hole of mounting plate Secure magnet housing on door or window parallel to the detector housing Secure mounting plate on door or window frame with #6 (M 3. 5) mounting screws Figure 5 Route wires through the PCB housing and connect to terminal block. Connect PCB housing to mounting plate. After mounting plate is secured to wall, route wire through wire entry hole of PCB housing and PCB board. Strip wire ends and connect to terminal block. Breakout tab FG-1008 CONFIGURATION Configure jumpers W1-W3 to best suit the application. To disable the LED operation, remove the jumper from position W1 on the PCB. To disable the magnetic contact, place a jumper across W3. PCB wire entry hole Terminal block NOTE: For proper wiring methods, refer to the National Electrical Code, NFPA 70. Breakout tab STEP Figure 6 Jumper settings JUMPER W1 (LED) W2 (LATCH) W3 (CONTACT DISABLE) 1 2 4 = Factory defaults ON LEDs are enabled OFF LEDs are disabled except during powerup test Red alarm LED lights for 5 seconds when detector alarms Magnetic contact is enabled TESTING The FG-1008 should be tested at least once each year. The model FG-700 Glassbreak Simulator can be used if it is set for the TEMPered glass sound. Other glassbreak simulators will not give an accurate indication of range. You must place the FG-1008 into Test Mode before you can test the detector. 2 Red alarm LED latches ON when detector alarms1, 2 Magnetic contact is disabled Latched alarm LED does not affect timing of alarm relay. Reset the alarm LED by removing and restoring power, or by momentarily removing and replacing the LATCH jumper. TESTING continued. . . To activate Test Mode: 1. Point the front of the simulator at the detector and press the red start button. You should hear a short buzz from the simulator, and the green LED on the FG1008 should begin flashing about once per second to indicate it is in Test Mode. If an FG-701 is not available, or if for any reason remote activation cannot be used, use a small screwdriver to short the test pads at location W4 on the PCB (see Figure 8). Make sure to replace the front cover of the FG1008 before beginning test. NOTE: In Test Mode the LED disable jumper is overridden. IMPORTANT: Some environmental factors may reduce the detector activation range. [. . . ] The FG-1008 will also automatically exit Test Mode after ten minutes. Figure 9 Testing Figures 10a&b Hold FG-701 behind window coverings when testing Test Magnetic Contact if Applicable With the magnetic contact enabled, the detector will signal an alarm to the control panel when the normally closed magnetic contact opens. To reset the alarm relay, the magnetic contact must be closed (the door or window on which it is mounted must be closed). FG-701 Glassbreak Simulator 3 LED Indicators The two LEDs shining through the front cover are used to indicate the detector's operational status. The following table summarizes the LED operation when the LEDs are enabled. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE INTELLISENSE FG-1008




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual INTELLISENSE FG-1008 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.