User manual HITACHI SJ100

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HITACHI SJ100. We hope that this HITACHI SJ100 user guide will be useful to you.


HITACHI SJ100 : Download the complete user guide (5148 Ko)

You may also download the following manuals related to this product:

   HITACHI SJ100 BROCHURE (3590 ko)
   HITACHI SJ100 SERVICE MANUAL (1942 ko)
   HITACHI SJ100 SPECIFICATIONS (105 ko)
   HITACHI SJ100 SUPPLEMENTAL SHEET (179 ko)
   HITACHI SJ100 QUICK REFERENCE GUIDE (400 ko)

Manual abstract: user guide HITACHI SJ100

Detailed instructions for use are in the User's Guide.

[. . . ] Cover HITACHI SJ100 Series Inverter Instruction Manual · Single-phase Input 200V Class · Three-phase Input 200V Class · Three-phase Input 400V Class Manual Number: NB585XF December 2003 After reading this manual, keep it handy for future reference. Hitachi Industrial Equipment Systems Co. , Ltd. SJ100 Inverter i Safety Messages For the best results with the SJ100 Series inverter, carefully read this manual and all of the warning labels attached to the inverter before installing and operating it, and follow the instructions exactly. Keep this manual handy for quick reference. Definitions and Symbols A safety instruction (message) includes a "Safety Alert Symbol" and a signal word or phrase such as WARNING or CAUTION. Each signal word has the following meaning: HIGH VOLTAGE: This symbol indicates high voltage. It calls your attention to items or operations that could be dangerous to you and other persons operation this equipment. [. . . ] You can choose the rate of deceleration that the inverter uses to lower the output current. "B" Function Func. Code Name / SRW Display Description Select the operating mode during overload conditions, three options, option codes: ON 00. . . Enabled for constant speed only Run Mode ­FE Edit (CE) 01 Defaults Motor Current B 22 0 t Output frequency 0 B 23 Restriction area t Configuring Drive Parameters ­FU (UL) 01 ­FR Units (Jpn) 01 -- B_21 Overload restriction operation mode OLOAD MODE B_22 Overload restriction setting Sets the level for overload restriction, between 50% and 150% of the rated current of OLOAD LVL 03. 75A the inverter, setting resolution is 1% of rated current Sets the deceleration rate when inverter detects overload, range is 0. 1 to 30. 0, resolution is 0. 1. Rated current x 1. 25 A B_23 Deceleration rate at overload restriction OLOAD CONST 01. 0 1. 0 1. 0 1. 0 -- 3­28 "B" Group: Fine Tuning Functions Software Lock Mode The software lock function keeps personnel from accidentally changing parameters in the inverter memory. The table below lists all combinations of B_31 option codes and Run the ON/OFF state of the [SFT] input. Each Check or Ex Mode indicates whether the corresponding parameter(s) can be edited. Edit The Standard Parameters column below shows access is permit ted for some lock modes. These refer to the parameter tables throughout this chapter, each of which includes a column titled Run Mode Edit as shown to the right. The marks (Check or Ex ) under the "Run Mode Edit" column title indicate whether access applies to each parameter as defined in the table below. In some lock modes, you can edit only F_01 and the Multi-speed parameter group that includes A_20, A220, A_21­A_35, and A_38 (Jog). The editing access to B_31 itself is unique, and is specified in the right-most two columns below. B_31 Lock Mode [SFT] Intelligent Input OFF ON 01 OFF ON 02 03 (ignored) (ignored) Standard Parameters Stop Run Run mode edit access Run mode edit access F_01 and Multi-Speed Stop & Run Stop B_31 Run Configuring Drive Parameters 00 NOTE: Since the software lock function B_31 is always accessible, this feature is not the same as password protection used in other industrial control devices. SJ100 Inverter 3­29 "B" Function Func. Code Name / SRW Display Description Prevents parameter changes, in four options, option codes: 00. . . all parameters except B_31 and output frequency F_01 when [SFT] terminal is ON 02. . . all parameters except B_31 and output frequency F_01 setting are locked Run Mode ­FE Edit (CE) 01 Defaults ­FU (UL) 01 ­FR Units (Jpn) 01 -- B_31 Software lock mode selection S-LOCK MD1 NOTE: To disable parameter editing when using B_31 lock modes 00 and 01, assign the [SFT] function to one of the intelligent input terminals. See "Software Lock" on page 4­19. Configuring Drive Parameters 3­30 "B" Group: Fine Tuning Functions Miscellaneous Settings The miscellaneous settings include scaling factors, initialization modes, and others. this section covers some of the most important settings you may need to configure. B_83: Carrier frequency adjustment ­ The internal switching frequency of the inverter circuitry (also called the chopper frequency). It is called the carrier frequency because the lower AC output frequency of the inverter "rides" the carrier. The faint, high-pitched sound you hear when the inverter is in Run Mode is characteristic of switching power supplies in general. The audible sound decreases at the higher frequencies, but RFI noise and leakage current may be increased. Refer to the specification derating curves in Chapter 1 to determine the maximum allowable carrier frequency setting for your particular inverter and environmental conditions. NOTE: When DC braking is performed, the inverter automatically holds the carrier frequency at 1 kHz. NOTE: When the inverter is in sensorless vector mode, use B_83 to set the carrier frequency greater than 2. 1 kHz for proper operation. Configuring Drive Parameters NOTE: The carrier frequency setting must stay within specified limits for inverter-motor applications that must comply with particular regulatory agencies. [. . . ] · Some motors have a rubber gasket between terminal box and motor housing. Very often, the terminal boxes, and particularly the threads for the metal PG screw connections, are painted. Make sure there is always a good metallic connection between the shielding of the motor cable, the metal PG screw connection, the terminal box, and the motor housing. If necessary, carefully remove paint between conducting surfaces. Appendix C SJ100 Inverter C­3 4. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HITACHI SJ100




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HITACHI SJ100 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.