User manual HITACHI L100DN ADDENDUM 01-2003

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HITACHI L100DN. We hope that this HITACHI L100DN user guide will be useful to you.


HITACHI L100DN ADDENDUM 01-2003: Download the complete user guide (2448 Ko)

Manual abstract: user guide HITACHI L100DNADDENDUM 01-2003

Detailed instructions for use are in the User's Guide.

[. . . ] L100DN TM DeviceNet Series Inverters Addendum to L100 Series Inverter Instruction Manual In This Addendum. . . . page -- Getting Started . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70 In the Appendices: -- DeviceNet Object Lists . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94 READ THIS FIRST! Addendum Number: NB642X Addendum for Manual: NB576X 2 Revisions Revision History Table No. [. . . ] If power has been connected, wait five minutes after powerdown and verify the Power LED is OFF before opening the inverter front door panel. 46 Network Control and Monitoring Step 3 ­ Prepare Network Host Computer for Network This step presumes that you have already connected your network host device (PLC or computer) to the DeviceNet network. If using a PC, the addition of a DeviceNet scanner card is usually required. Master (network host) EDS file Inverter Addr=?(you select) Addr=63 (default) Load EDS file ­ The I/O structure of smart field devices such as inverters are unique. Consequently, you must provide a network host computer with the I/O image of smart devices on the network. DeviceNet standards provide for a quick way to equip host computers with device-specific I/O images. Manufacturers develop EDS files for their DeviceNetcompatible products, providing them to the DeviceNet standards organization. The ODVA (Open DeviceNet Vendors Association) maintains the files for download. Do the following steps: · Visit the website at http://www. odva. org · Navigate to the Downloads area, and then to EDS files. · From the EDS files, select "Hitachi" as the manufacturer. · Download the file that matches your inverter's version (L100DN2, for example) · Then load or place the EDS file in your network host device in the location (directory) it requires for use in network device scanning. Set node address of host ­ If you have not already done so, set the node address (the MAC ID). Refer to the documentation of your host device for the address setting procedure. We recommend not using "00, " since that is the default of many other devices. Set baud rate of host ­ The host computer's baud rate and the inverter's baud rate must match in order for them to communicate. We recommend using the lowest baud rate (125 kbaud) to get the network up and running. The default baud rate of the inverter is 125 kbaud. L100DN Inverter 47 Step 4 ­ Prepare Inverter for Network Verify that the inverter's DeviceNet parameters are set as directed. · P_41 baud rate setting must be the same as your network host computer. · P_42 MAC ID setting must be different from your network host computer. · P_43 DeviceNet enable must be set = 1 (required by subsequent steps in example). · P_44 and P_45 are recommended to remain at the default settings. · P_46 and P_47 must be set to the default values (required by subsequent steps). · P 48 selects the inverter's action if the inverter detects network idle (leave at default). [. . . ] Code Name Default Setting ­F (Japan) User Setting F_01 F_02 F_03 F_04 Output frequency setting Acceleration (1) time setting Deceleration (1) time setting Keypad Run key routing 0. 0 10. 0 10. 0 00 0. 0 10. 0 10. 0 00 0. 0 10. 0 10. 0 00 L100DN Inverter 89 Standard Functions "A" Group Parameters Func. Code Name -FE (Europe) Default Setting -FU (USA) ­F (Japan) User Setting A_02 A_03 A_04 A_20 A_21 A_22 A_23 A_24 A_25 A_26 A_27 A_28 A_29 A_30 A_31 A_32 A_33 A_34 A_35 A_38 A_39 A_41 A_42 A_43 A_44 A_45 A_51 A_52 A_53 Run command source setting Base frequency setting Maximum frequency setting Multi-speed 0 setting Multi-speed 1 setting Multi-speed 2 setting Multi-speed 3 setting Multi-speed 4 setting Multi-speed 5 setting Multi-speed 6 setting Multi-speed 7 setting Multi-speed 8 setting Multi-speed 9 setting Multi-speed 10 setting Multi-speed 11 setting Multi-speed 12 setting Multi-speed 13 setting Multi-speed 14 setting Multi-speed 15 setting Jog frequency setting Jog stop mode Torque boost method selection Manual torque boost value Manual torque boost frequency adjustment V/f characteristic curve selection V/f gain setting DC braking enable DC braking frequency setting DC braking wait time 01 50. 0 50. 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1. 0 00 00 11 10. 0 00 100 00 0. 5 0. 0 01 60. 0 60. 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1. 0 00 00 11 10. 0 00 100 00 0. 5 0. 0 02 60. 0 60. 0 0 5 10 15 20 30 40 50 60 0 0 0 0 0 0 0 1. 0 00 00 11 10. 0 00 100 00 0. 5 0. 0 90 Drive Parameter Settings Tables "A" Group Parameters Func. Code Name -FE (Europe) Default Setting -FU (USA) ­F (Japan) User Setting A_54 A_55 A_61 A_62 A_63, A_65, A_67 A_64, A_66, A_68 A_81 A_82 A_92 A_93 A_94 A_95 A_96 A_97 A_98 DC braking force during deceleration DC braking time for deceleration Frequency upper limit setting Frequency lower limit setting Jump (center) frequency setting 0 0. 0 0. 0 0. 0 0. 0 0 0. 0 0. 0 0. 0 0. 0 0 0. 0 0. 0 0. 0 0. 0 Jump (hysteresis) frequency width setting AVR function select AVR voltage select Acceleration (2) time setting Deceleration (2) time setting Select method to switch to Acc2/ Dec2 profile Acc1 to Acc2 frequency transition point Dec1 to Dec2 frequency transition point Acceleration curve selection Deceleration curve selection 0. 5 0. 5 0. 5 02 230/400 15. 0 15. 0 00 0. 0 0. 0 00 00 00 230/460 15. 0 15. 0 00 0. 0 0. 0 00 00 02 200/400 15. 0 15. 0 00 0. 0 0. 0 00 00 L100DN Inverter 91 Fine Tuning Functions "B" Group Parameters Func. Code Name -FE (Europe) Default Setting -FU (USA) ­F (Japan) User Setting B_01 B_02 B_03 B_12 Selection of automatic restart mode Allowable under-voltage power failure time Retry wait time before motor restart Level of electronic thermal setting 00 1. 0 1. 0 Rated current for each inverter 01 01 Rated current x 1. 25 1. 0 01 Rated current x 0. 40 0. 5 5. 0 00 01 1. 0 00 00 00 1. 0 1. 0 Rated current for each inverter 01 01 Rated current x 1. 25 1. 0 01 Rated current x 0. 40 0. 5 5. 0 00 02 1. 0 00 00 00 1. 0 1. 0 Rated current for each inverter 00 01 Rated current x 1. 25 1. 0 01 Rated current x 0. 40 0. 5 12. 0 00 00 1. 0 00 00 B_13 B_21 B_22 Electronic thermal characteristic Overload restriction operation mode Overload restriction setting B_23 B_31 B_32 Deceleration rate at overload restriction Software lock mode selection Reactive current setting B_82 B_83 B_84 B_85 B_86 B_87 B_88 Start frequency adjustment Carrier frequency setting Initialization mode (parameters or trip history) Country code for initialization Frequency scaling conversion factor STOP key enable Restart mode after FRS 92 Drive Parameter Settings Tables Intelligent Terminal Functions "C" Group Parameters Func. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HITACHI L100DN




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HITACHI L100DN will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.