User manual HASE VALENCIA

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HASE VALENCIA. We hope that this HASE VALENCIA user guide will be useful to you.


HASE VALENCIA : Download the complete user guide (2351 Ko)

You may also download the following manuals related to this product:

   HASE VALENCIA DATASHEET (702 ko)
   HASE VALENCIA DATASHEET 2 (266 ko)
   HASE VALENCIA FICHE TECHNIQUE (385 ko)
   HASE VALENCIA ANNEXE 649 DATASHEET (147 ko)

Manual abstract: user guide HASE VALENCIA

Detailed instructions for use are in the User's Guide.

[. . . ] Dear Hase customer, These operating instructions provide important information about the safe operation and handling of your Valencia stove. Please read carefully through these operating instructions before using the stove for the first time. In addition, your Valencia stove comes with general operating instructions (part II) containing further instructions and helpful tips on how to use Hase stoves. [. . . ] The thermal output depends on the amount of fuel you put in the stove. When adding more fuel, please do not exceed the maximum fuel load size of 2. Exceeding the maximum fuel load size leads to a danger of overheating, which can result in damage to the stove and the risk of a stove fire. During shipment, condensation moisture can accumulate in the stove's interior, which may possibly lead to the appearance of condensation or water on the stove or flue pipes. Make sure the room is well-ventilated and open the windows and outside doors. If the maximum temperature is not reached during the first heating operation, you may notice an odour for a short period of time the next time the stove is used as well. The surface of your stove was treated in a sandblasting machine before applying the colour coating. Despite careful and thorough inspection, there may still be some residual material in the stove body, which can fall out when your stove is being installed. To prevent any damage, please immediately vacuum up these small steel pellets with a vacuum cleaner. The first time a stove is operated, the heat development causes the emission of volatile components from the coating, sealing strips and lubricants, and smoke and odours can occur. At a higher combustion temperature, this one-time process can take between 4 to 5 hours. To achieve this higher combustion temperature, please increase the fuel quantity recommended in Section 7, , , Adding Fuel/ Heating with Nominal Thermal Output", by approximately 25%. To prevent adverse effects on health, nobody should stay in the room(s) during this process The firing up phase should be as short as possible, since higher emissions can occur during this phase. The slider settings described in Table 1 (see figure on the right) are recommendations that were determined under conformance testing conditions, in compliance with the relevant standard. [. . . ] (A): FSPS-Wa 1853 -A The following data applies to the chimney characteristics in accordance with EN 13384-1 / 2: Combustion Values Depending on the insulation of the building, the nominal thermal output of 8 kW indicated on 30 - 115 m² (subject to change) Dimensions: Stove Fire box Height 200, 5 cm - variable 51, 5 cm Ceramic Weight: 343 kg Soapstone 386 kg Width 86 cm 31, 5 cm The original Declaration of Conformity and associated documents are available from the manufacturer upon request. 14 54294 Trier / Germany Hereby declares that the room heating appliance for use with solid fuels, bearing the trade name: Va l e n c i a complies with the stipulations and provisions of the: CE Construction Products Directive 89/106/EEC and the M129 Mandate and is in compliance with the following harmonised standard: EN 13240:2001+EN 13240:2001/ A2: 2004 The notified testing institute listed below has performed the inspection and testing of the room heating appliance for use with solid fuels in regards to conformity with the requirements specified by the standard: RWE Power AG Feuerstättenprüfstelle D-50226 Frechen Kennziffer: NRW 16 Trier, Germany, dated 12. Fernando Najera , Executive Manager Please observe the safety notes and precautions contained in the installation and operating instructions that are shipped with the product. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HASE VALENCIA




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HASE VALENCIA will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.