If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual GRACO QUIET VISCOUNT II. We hope that this GRACO QUIET VISCOUNT II user guide will be useful to you.
Manual abstract: user guide GRACO QUIET VISCOUNT IIPARTS LIST
Detailed instructions for use are in the User's Guide.
[. . . ] InstructionsParts List
Quiet ViscountR II Hydraulic Motor
Used as hydraulic drive for reciprocating pumps. For professional use only.
Model 223646, Series B
1500 psi (10 MPa, 103 bar) Maximum Hydraulic Fluid Input Pressure
Patent No. 4, 792, 291 Foreign Patents Pending
308048K
ENG
Important Safety Instructions Read all warnings and instructions in this manual. 16
04471
Symbols
Warning Symbol Notice Symbol
WARNING
This symbol alerts you to the possibility of serious injury or death if you do not follow the instructions.
NOTICE
This symbol alerts you to the possibility of damage to or destruction of equipment if you do not follow the corresponding instructions.
WARNING
EQUIPMENT MISUSE HAZARD
Equipment misuse can cause the equipment to rupture or malfunction and result in serious injury.
INSTRUCTIONS
D This equipment is for professional use only. [. . . ] 2
14
04468
6
308048
Service
Pressure Relief Procedure Before you start:
Be sure you have all necessary parts on hand. An asterisk behind a reference number in the parts list, for example (21*), indicates that the part is included in the repair kit. Clean all parts as you disassemble them and inspect them for wear or damage. Use Loctiter TL242 thread sealant, or the equivalent, when thread sealant is specified.
WARNING
SKIN INJECTION HAZARD The system pressure must be manually relieved to prevent the system from starting or spraying accidentally. Fluid under high pressure can be injected through the skin and cause serious injury. To reduce the risk of an injury from injection, splashing fluid, or moving parts, follow the Pressure Relief Procedure whenever you: D D D D are instructed to relieve the pressure, stop spraying, check or service any of the system equipment, or install or clean the spray tip.
Disassembly (Refer to Fig. 3)
NOTE: Use all the replacement parts that are in the repair kit.
1. Close the supply line shutoff valve, and then the return line shutoff valve. Hold a metal part of the gun firmly to the side of a grounded metal pail, and trigger the gun to relieve pressure. Open the drain valve (required in your system), having a container ready to catch the drainage. If you suspect that the spray tip or hose is completely clogged, or that pressure has not been fully relieved after following the steps above, very slowly loosen the tip guard retaining nut or hose end coupling and relieve pressure gradually, then loosen completely. Flush the displacement pump if possible.
WARNING
To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 7. Relieve the pressure.
NOTICE
Avoid getting dust or dirt in the motor during service. Disconnect the hydraulic hoses and plug all hydraulic connections and lines to prevent contamination.
308048
7
Service
Disassembly (continued refer to Fig. Disconnect the displacement pump from the motor, as explained in your separate pump manual. Pull the trip rod and piston from the lower housing (25) and cylinder (29). Place the piston flats (30) in a vise; tighten the vise on the flats of the piston. If the piston is replaced, remove the spring (26) to use in the new piston. Remove the bearing (23), packings (24), and o-ring (21).
8
308048
Service
50 51 47 48 44 52 53 43 42 56 40* 41 39 54 54a 46 6a 6 38 *45 B 37 34 28 35 36 27 21* 2 3 3a 37 45* 4 31 23* 24* 33*
*49 55a 55 54 54a 7a 7 58 5 B
57
B
29 33* 24*
B
A
25
A
A
*32 26 15 14
19 30 20 18 13 16 *17 12
NOTE: Circled letters refer to connected points.
04466
Fig. Install them in the lower housing (25) with the lips facing up toward the top of the motor. The compression rings (32*) must be positioned with the joints about 180_ opposed. With the piston flats in a vise, tighten the retainer until it is flush or below the piston surface. [. . . ] 290398).
308048
13
Mounting Hole Layout
1 4 5 6 2
Dimensions
2
3 4
1 2
02589
1 2 3 4 5 6 7
Four 0. 437 in. (5. 08 cm) Three 5/811 UNC (2B) tapped holes Gasket 161806 is not shown. stroke
5
02631
14
308048
Technical Data
Category Maximum hydraulic fluid input pressure Maximum hydraulic fluid flow Hydraulic fluid consumption Effective piston area Piston rod diameter Stroke length Thrust at 1500 psi (10 MPa, 103 bar) Weight Loctiter is a registered trademark of the Loctite Corp. Sound Data Hydraulic Pressure 1500 psi (10 MPa, 103 bar) dB(A) at 20 cycles per minute 70 dB(A) at 30 cycles per minute 78 dB(A) at 60 cycles per minute 79 Data 1500 psi (10 MPa, 103 bar). [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE GRACO QUIET VISCOUNT II
Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual GRACO QUIET VISCOUNT II will begin.