User manual FURUNO NX-700 OPERATORS MANUAL
DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual FURUNO NX-700. We hope that this FURUNO NX-700 user guide will be useful to you.
Manual abstract: user guide FURUNO NX-700OPERATORS MANUAL
Detailed instructions for use are in the User's Guide.
[. . . ] NAVTEX RECEIVER
NX-700A/B
The paper used in this manual is elemental chlorine free.
FURUNO Authorized Distributor/Dealer 9-52 Ashihara-cho, Nishinomiya 662-8580, JAPAN Telephone : Fax : 0798-65-2111 0798-65-4200
All rights reserved.
Printed in Japan
FIRST EDITION : MAY. OME-56490 ( HIMA ) NX-700A/B
*00015280402* *00015280402*
*00015280402*
*OME56490C00* *OME56490C00*
*OME56490C00*
IMPORTANT NOTICE
· · · ·
No part of this manual may be copied or reproduced without written permission. If this manual is lost or worn, contact your dealer about replacement. The contents of this manual and equipment specifications are subject to change without notice. [. . . ] Note: If the station ID was not entered at step 14, the message "Enter ID data. " appears. OPERATION
Editing NAVTEX station Existing NAVTEX station may be edited as follows: Press the MENU/ESC key to show the main menu. Press the LIST key to choose the frequency to be changed (518kHz, 490kHz or 4209. 5kHz). Press to choose "Edit", and then press ENT key to show the edit window appears.
Oostende
NAV Area Station Name
Latitude Longitude
Station ID Service Area
NavArea 1 Station Oostende Latitude 51 11'N Longitude 2 48'E 518kHz ID1: T ID2: - ID3: 490kHz ID1: - ID2: - ID3: 4209. 5kHz ID1: A ID2: - ID3: Range 55nm Save data ?
Edit window (Ex. Press to choose "YES", and then press the ENT key to erase the edit window. Deleting NAVTEX stations
You may delete unnecessary NAVTEX stations as follows: 1. Press the LIST key to choose the frequency to be deleted (518kHz, 490kHz or 4209. 5kHz). Press or to choose the station name to be deleted, and then press ENT key. Press to choose "Yes", and then press the ENT key to close the edit window. Press the MENU/ESC key several times to close the menu.
2. 14
Icons
The NX-700 shows various icons to denote equipment status, and these are as shown in the table below.
Icon Status Meaning
Status icon (shown at the tip of display)
Blinking
Shows that an International frequency (518 kHz) message has not been read.
Shows that a Local frequency message has not been read. I: International frequency (518 kHz) L1: 490 kHz L2: 4209. 5 kHz
Displayed when the voltage of the internal battery is low. While printing.
L1
L2
I L1 L2
Blinking
Blinking Blinking Blinking Blinking
Lighting
X
Lighting Lighting
P R
Message icon (shown next to messages) NEW Lighting Displayed when message is displayed for the first time. (This icon disappeared after showing the detail or 24 hours has passed. ) Displayed when message type D (SAR) is displayed. Appears when message type A, B or L (Warning) is displayed.
Protected message
SAR !!
Lighting Lighting
Lighting
2-15
2. OPERATION
2. 15
Messages List
In addition to the message "Received new local (int'l) msg. " the following message-related messages may appear on the display. Message not chosen for display received; it is a int'l 00 message. Choose "All Message"(LIST menu) to display.
Meaning Appears when the oldest message is deleted to make space for the latest one. Appears when two messages have the same ID are received and the latter's error rate is lower than the former. Appears when 66 hours has passed after receiving the currently displayed message. Appears when receiving an international message not specified for display (00) at the SELECT MESSAGES display. Appears when receiving a local message not specified for display (00) at the SELECT MESSAGES display. Appears when receiving an international message not specified for display (Normal) at the SELECT MESSAGES display. [. . . ] 20 mm/sec.
SP - 1
E5649S01D-M
FURUNO
4
4. 1 4. 2 4. 3
NX-700A/B
ANTENNA UNIT
Antenna type Output impedance Power supply NX-7H: H-field antenna 50 ohms +7 V to +9 V (thru co-ax cable)
5 5. 1
INTERFACE
Input data Output data IEC61162-1, -2 GGA, GLL, RMC, ZDA, NRQ, NMK, ACK, GNS, VHW, VTG, VBW NRX, ALR Normal close, contact closure signal (floating, max. 80 mA, 50 V) for SAR alert
5. 2
Alarm
6
POWER SUPPLY
12-24VDC: 12-24VDC: 1. 5-0. 8A 0. 7-0. 4A
6. 1 NX-700A 6. 1 NX-700B
7
7. 1
ENVIRONMENTAL CONDITION
Ambient temperature Antenna unit Receiver / Display unit -25°C to +70°C -15°C to +55°C 95% at 40°C (without dew condensation) IP66 IP20 (NX-700B: IP25 for front panel) - 2Hz to 5 Hz and up to 13. 2 Hz with a deviation of ±1 mm ±10% (7 m/s2 maximum acceleration at 13. 2 Hz); - above 13. 2 Hz and up to 100 Hz with a constant maximum acceleration of 7 m/s2 .
7. 2 7. 3
Relative humidity Waterproofing Antenna unit Receiver / Display unit
7. 4 Vibration
8
8. 1 8. 2 8. 3
COATING COLOR
Display unit Receiver unit Antenna unit N3. 0 N3. 0 N9. 5
SP - 2
E5649S01D-M
A-1
A-2
A-3
A-4
A-5
A-6
A-7
A-8
A-9
A-10
A-11
D-1
Y. Hatai
D-5
-
1 2
EXTENSION CABLE KIT OP04-2 *2 FMA-1 M-P-3 04S4168, 5. 5 10/20/30/40/50m M-P-3 0. 6m M-P-3
3
4
ANTENNA UNIT NX-7H
A
RECEIVER UNIT NX-7001
ANT M-P-3 04S4168, 10/20/30/40/50m, 5. 5 PL-259(*1) M-P-7 PL-259(*1) FM-MP-7 RG-214(*1) 200m MAX. RG-10/UY, 30/40/50m *2 *2 DSUB25P-DSUB25P-5M/10M/15M, 5/10/15m DSUB25P-DSUB25P-3M, 3m, 10
P P P P P P P P P
INS
*1 TTYCS-1Q *1 TTYCS-1Q 1 2 3 4 5 6 J402(WAGO) TD-A (IEC61162-2) TD-B GND-ISO RD-A RD-B FG
NAVIGATOR
NX-700A/B
EXT. [. . . ]