[. . . ] DH Instruments disclaims any responsibility or liability for any direct or indirect damages resulting from the use of the information in this manual or products described in it. Mention of any product does not constitute an endorsement by DH Instruments of that product. This manual was originally composed in English and subsequently translated into other languages. [. . . ] Max working pressure of VLI P/N 100693 is 100 MPa (15 000 psi)
1. 2
OPERATING PRINCIPLE
This component interfaces two pressure media in a high pressure chamber. Using two media of different densities allows a natural separation between the two fluids that can be referenced to an indicating pointer in the VLI and viewed through a transparent lens.
1. 3
COMPONENT LOCATION
1. 7.
Stand Reference Pointer Upper Pet-cock Overflow Port Upper Pressure Interface Port Lower Interface Port Drain Cock
Figure 1. VLI Components
Page 1
© 1998 - 2007 DH Instruments, a Fluke Company
VLITM OPERATION & MAINTENANCE MANUAL
NOTES
© 1998 - 2007 DH Instruments, a Fluke Company
Page 2
2. INSTALLATION
2.
2. 1
INSTALLATION
UNPACKING AND INSPECTION
The VLI consists of the following items:
Table 1. Visible Level Interface (VLI) DH 1500 Gland (1500 bar, metric thread) DH 1500 Collar (1500 bar) DH 1500 Plug (1500 bar) O-Ring (spare) 4x12 mm Button Head Screw Operation and Maintenance Manual OPTIONAL 1 ea. VLI Stand, High OR VLI Stand, Low PART # 100693 100265 100278 102053 101063 NPN 550039 PART # 100703 100702
2. 2
INITIAL SETUP
Place the VLI on the same surface as the piston gauge or other reference to which it is to be connected. Ensure the VLI and the connecting hardware are clean and free of contamination. Connect the VLI to the standard using the connecting hardware supplied. If the piston gauge medium has the greater density, the connection should be made at the lower port of the VLI. If this is not true, then the connection should be made at the middle port. Fill the VLI through the connecting hardware to the tip of the interface level indicator with the fluid that has the highest density. Carefully fill the rest of the VLI with the lighter medium until the air is completely displaced form the VLI. When interfacing a gas medium with a liquid medium the control of pressure must be performed on the gas side. A variable volume in the hydraulic side is necessary to adjust the change in the interface level as pressures and temperatures change.
Page 3
© 1998 - 2007 DH Instruments, a Fluke Company
VLITM OPERATION & MAINTENANCE MANUAL
2. 3
OPERATION
2. 3. 1 INTERFACING TWO LIQUIDS (OIL, WATER, ETC. )
Pressures can be generated from either side, or on both sides. The interface reference level can then be changed by adjusting the volume on either side. [. . . ] This condition could lead to outgassing (rapid boiling) when returning to zero. To prevent boiling liquid into the gas or gas into the liquid, decrease pressures slowly to approximately 200 psi (1. 4 MPa). Hold that pressure until outgassing has apparently stopped and then decrease to zero.