User manual EUTECH INSTRUMENTS HIGHLOW TDS TESTER

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual EUTECH INSTRUMENTS HIGHLOW TDS TESTER. We hope that this EUTECH INSTRUMENTS HIGHLOW TDS TESTER user guide will be useful to you.


EUTECH INSTRUMENTS HIGHLOW TDS TESTER : Download the complete user guide (401 Ko)

Manual abstract: user guide EUTECH INSTRUMENTS HIGHLOW TDS TESTER

Detailed instructions for use are in the User's Guide.

[. . . ] However, to ensure accuracy, calibrate conductivity on a regular basis. Select a calibration standard appropriate for the ECScan High tester (between 2. 00 mS and 19. 90 mS). Rinse electrode in deionized water, then rinse it in calibration standard, then dip it into a container of calibration standard. Press the INC or DEC key to adjust reading to match the calibration standard value. [. . . ] Rinse electrode in deionized water, then rinse it in calibration standard, then dip it into a container of calibration standard. Press the INC or DEC key to adjust reading to match the calibration standard value. After 3 seconds without a key press, the display flashes 3 times, then shows `ENT'. Replace battery cap. HOLD Function Press HOLD key to freeze display. Press HOLD again to release. Tester Maintenance · To improve performance, clean the electrode by rinsing them in alcohol for 10 to 15 minutes. · Replace all batteries if low battery indicator appears, or if readings are faint or unstable. · If you experience drift, periodically let electrode fully dry. When you need a new electrode, see "Electrode Replacement" on insert in back of box. Self-Diagnostic Messages bAt Weak batteries­replace with fresh ones specified by manufacturer. Or, Ur Over range/Under range signal, or electrode is not in contact with solution, or electrode is failing. ---- Calibration mode activated but not performed. 68X247754 11/00 Rev 0 Open this leaflet for calibration/testing/maintenance instructions. Changing Batteries 1. Recalibrate after battery change. Tester Maintenance · To improve performance, clean the electrode by rinsing them in alcohol for 10 to 15 minutes. · Replace all batteries if low battery indicator appears, or if readings are faint or unstable. · If you experience drift, periodically let electrode fully dry. When you need a new electrode, see "Electrode Replacement" on insert in back of box. Warranty Eutech Instruments warrants its meter free from manufacturing defects for 2 years and electrode module for 6 months. If repair, adjustment or replacement is necessary and has not been the result of abuse or misuse within the time period, please return the tester ­ freight prepaid ­ and correction will be made without charge. Out of warranty products will be repaired on a charge basis. + + Return Of Items Authorization must be obtained from Eutech's distributor before returning items for any reason. When applying for authorization, please include information regarding the reason the item(s) are to be returned. Note: We reserve the right to make improvements in design, construction and appearance of products without notice. Prices are subject to change without notice. · Waterproof & Floats · Replaceable Electrode · Auto-off · Adjustable TDS Factor · Automatic Temperature Compensation (ATC) WP TDScan High Instructions Before You Begin Remove electrode cap. Soak electrode for a few minutes in alcohol to remove oils. TDS Testing 1. Wait for reading to stabilize (Automatic Temperature Compensation corrects for temperature changes). Note: Tester automatically shuts off after 8. 5 minutes of non-use. Calibration Tester is factory calibrated. [. . . ] When applying for authorization, please include information regarding the reason the item(s) are to be returned. Note: We reserve the right to make improvements in design, construction and appearance of products without notice. Prices are subject to change without notice. · Waterproof & Floats · Replaceable Electrode · Auto-off · Adjustable TDS Factor · Automatic Temperature Compensation (ATC) WP TDScan Low Instructions Before You Begin Remove electrode cap. Soak electrode for a few minutes in alcohol to remove oils. TDS Testing 1. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE EUTECH INSTRUMENTS HIGHLOW TDS TESTER




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual EUTECH INSTRUMENTS HIGHLOW TDS TESTER will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.