User manual EUTECH INSTRUMENTS ALPHA CON 1000 CONDUCTIVITY CONTROLLERTRANSMITTER (REVISION 3)

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual EUTECH INSTRUMENTS ALPHA CON 1000 CONDUCTIVITY CONTROLLERTRANSMITTER (REVISION 3). We hope that this EUTECH INSTRUMENTS ALPHA CON 1000 CONDUCTIVITY CONTROLLERTRANSMITTER (REVISION 3) user guide will be useful to you.


EUTECH INSTRUMENTS ALPHA CON 1000 CONDUCTIVITY CONTROLLERTRANSMITTER (REVISION 3) : Download the complete user guide (501 Ko)

Manual abstract: user guide EUTECH INSTRUMENTS ALPHA CON 1000 CONDUCTIVITY CONTROLLERTRANSMITTER (REVISION 3)

Detailed instructions for use are in the User's Guide.

[. . . ] Instruction Manual lpha-CON 1000 Conductivity Controller/Transmitter Technology Made Easy . . . 68X216802 rev 3, 11/04 This manual serves to explain the use of the lpha-CON1000 series Conductivity controller/transmitter. The manual functions in two ways: firstly as a step-by-step guide to help the user operate the instrument. This instruction manual is written to cover as many anticipated applications of the lpha-CON1000 Conductivity controller/transmitter. If you have doubts in the use of the instrument, please do not hesitate to contact the nearest Eutech Instruments' Authorised Distributor. [. . . ] Compare the current measured temperature on the controller display to a thermometer known to be accurate. HOLD Press the or keys to scroll the lower display to match the correct value. Continue with additional Advanced Set-up procedures, or return to the Measurement mode by pressing the and keys (escape) simultaneously). SETUP 2) 3) 4) 5) °C SETUP A SETUP 6) 0. 0 25. 0 °C 7) 8) ATC 7. 2. 1 Setting Manual Temperature Compensation HOLD SETUP NOTE: This parameter is blanked out when the controller is set for ATC operation. For manual temperature compensation, you can set two different temperatures: Process and Calibration. This allows calibration at a A temperature other than your process temperature. Example: setting a calibration temperature of 25 ºC lets you calibrate using standard buffer HOLD SETUP solutions at 25 ºC, even if your process temperature is at different °C temperature. 2) Press the or keys to scroll until the display shows "SEt ºC". The upper display shows the current calibration temperature and the lower display shows "C. ºC" to indicate calibration temperature. You can adjust the value from -9. 9 to 125 ºC. FF 25. 0 25. 0 13 Operating Instructions lpha-CON1000 8) 9) Press ENTER key to confirm your selection. Continue with additional Additional Set-up procedures, or return to Measurement mode by pressing the and keys (escape) simultaneously). 7. 3 Control Relay A/Control Relay B (SP1/SP2) sub-function The SP1 option sets the operating parameters for Relay A; and SP2 for relay B. Since these groups have the same set-up parameters, they are described together. HOLD SETUP HOLD SETUP HOLD µS SETUP HOLD SETUP HOLD µS SETUP HOLD SETUP Sp1 6 100 Sp1 L 6 Sp1 20 6 Hys 6 O. 0 6 OF. 0 7. 3. 1 Entering the Set point 1 (or Set point 2) sub-function The alpha CON 1000 controller/transmitter can operate in either one of the 10 different conductivity ranges (see Section 12. 2 ­ Appendix 2: Measurement Ranges Available in the Controller. Refer to Section 7. 5. 1 for Selecting the Measuring Range sub-function. Push the ENTER key and (use or keys to) scroll to Advanced Set-up security code "22". Press the or keys to scroll until the upper display shows SP1 (or SP2). HOLD Sp1 SETUP 7. 3. 2 Selecting the set point values This lets you choose the value that will cause your controller to activate (Default: SP1 = 100 µS; SP2 = 1900 µS). 1) Press the ENTER key until upper display shows the current set point value and the lower display shows SP1 (or SP2). 2) Press the or keys to select your value for Set point 1 (or Set point 2). 4) Proceed to 7. 3. 3, or return to Measurement mode by pressing the and keys simultaneously (escape). 100 6 µS Sp1 HOLD SETUP L 6 Sp1 14 Operating Instructions lpha-CON1000 7. 3. 3 Choosing High or Low set points Select a low set point to activate controller when the conductivity value undershoots the low set point; select a high set point to activate controller when the value overshoots the high set point. Using both SP1 and SP2, you can select lo/lo, lo/hi, hi/lo, or hi/hi set points (Default: SP1 = Lo; SP2 = Lo). Scroll with the or keys until the upper display shows Lo or Hi (for low or high set point) and the lower display shows SP1 (or SP2). 3) Press the or keys to select low (lo) or high (hi) set point for SP1 (or SP2). 5) Proceed to 7. 3. 4, or return Measurement mode by pressing the and keys simultaneously (escape). [. . . ] The relays are now back under automatic control. 25 Operating Instructions lpha-CON1000 9 TECHNICAL SPECIFICATIONS Conductivity Range 0. 000 to 1. 999 µS/cm 0. 00 to 19. 99 µS/cm 0. 0 to 199. 9 µS/cm 0 to 1999 µS/cm 0 to 5000 µS/cm 0. 00 to 19. 99 mS/cm 0. 0 to 199. 9 mS/cm Resolution 0. 001 µS/cm 0. 01 µS/cm 0. 1 µS/cm 1 µS/cm 5 µS/cm 0. 01 mS/cm 0. 1 mS/cm Default Cell Constant, K 0. 01 0. 01 0. 1 1. 0 1. 0 1. 0 10. 0 Optional Cell, K 0. 1 1. 0 1. 0 Temperature Resolution Relative Accuracy Sensor Temperature Compensation Set-point and Controller Functions Controller characteristics Pickup / Dropout delay Switching Condutivity hysteresis Contact outputs, controller Switching voltage Switching current Switching power Alarm Functions Function (switchable) Pickup delay Switching voltage Switching current Switching power Electrical Data and Connections Power Requirements Frequency Signal Output Signal Output Load Connection terminal Mains fuse / fine wire fuse EMC Specifications Emissions Susceptibility Environmental Conditions Ambient temp. operating range Relative humidity Mechanical Specifications Dimensions (control panel housing - L x H x W) Weights (control panel housing) Material Insulation (Front / Housing) 0-50 oC (Display: -9. 9 to 125 oC) 0. 1 oC ± 0. 5 oC Pt 1000/Pt 100 Auto / manual (reference at 25. 0 oC) Limit / proportional (pulse or frequency) controller 0 to 1999 sec. 600 VA 110 / 220 VAC (jumper selectable) 48 to 62 Hz 0/4 to 20 mA, galvanically isolated max. 600 Terminal blocks 5-pole / 17-pole, removable slow-blow 250 V / 100 mA According to EN 50081-1 According to EN 50082-1 0 to 50 oC 10 to 95%, non-condensing 175 x 96 x 96 mm max. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE EUTECH INSTRUMENTS ALPHA CON 1000 CONDUCTIVITY CONTROLLERTRANSMITTER (REVISION 3)




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual EUTECH INSTRUMENTS ALPHA CON 1000 CONDUCTIVITY CONTROLLERTRANSMITTER (REVISION 3) will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.