Detailed instructions for use are in the User's Guide.
[. . . ] ENMGS-16+2
16-Port 10/100/1000Mbps Web-Smart Gigabit Ethernet Switch
16 x 10/100/1000 Mbps RJ-45 Ports 2 x 1000Mbps mini-GBIC ports
User's Guide
FCC Warning
ENMGS-16+2 has been tested and found to comply with the regulations for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with this user's guide, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at his or her own expense.
CE Mark Warning
This is a Class A product. [. . . ] Reset: The Reset button is to reset all the setting back to the factory default. Note: Be sure that you recorded the setting of your device, else all the setting will be erased when pressing the "Reset" button.
14
UNDERSTANDING LED INDICATORS
The front panel LEDs provides instant status feedback, and, helps monitor and troubleshoot when needed.
Figure 6. LED indicators
Power and System LEDs
POWER: Power Indicator
On Off : When the Power LED lights on, the Switch is receiving power. : When the Power turns off or the power cord has improper connection.
SYSTEM: Management Indicator
Blinking On/Off : When the CPU is working, the System LED is blinking. : The CPU is not working.
15
1000BASE-T Port 1~16 Status LEDs
Link/ACT: Link/Activity
On : When the Link/ACT LED lights on, the respective port is successfully connected to an Ethernet network. When the Link/ACT LED is blinking, the port is transmitting or receiving data on the Ethernet network. No link.
Blinking
:
Off
:
1000Mbps
On : When the 1000Mbps LED lights on, the respective port is connected to a 1000Mbps Gigabit Ethernet network. When the respective port is connected to a 10Mbps Ethernet or 100Mbps Fast Ethernet network
Off
:
100Mbps
On : When the 100Mbps LED lights on, the respective port is connected to a 100Mbps Fast Ethernet network. When the respective port is connected to a 10Mbps Ethernet or 1000Mbps Gigabit Ethernet network.
Off
:
16
Combo mini-GBIC Port 15~ 16 Status LEDs
Link/ACT
On : When the fiber line connected to the mini-GBIC module is installed and connected to a network, the Link/ACT LED will lights on. When the Link/ACT LED is blinking, the port is transmitting or receiving data on the Gigabit Ethernet network. Fiber line or mini-GBIC module is not installed.
Blinking :
Off
:
1000Mbps
On : When the 1000Mbps LED lights on, the respective port is connected to a 1000Mbps Gigabit Ethernet network. When the respective port is connected to a 10Mbps Ethernet or 100Mbps Fast Ethernet network
Off
:
17
CONFIGURATION
Through the Web Browser you can configure the Switch such as VLAN, Port Trunking, Jumbo Frame. . . With the attached Web Management Utility, you can easily discover all the Web Management Switch, assign the IP Address, changing the password and upgrading the new firmware.
Installing the Web Management Utility
The following gives instructions guiding you through the installations of the Web Management utility. In the Run dialog box, type D:\Web Management Utility\setup. exe (D:\ depends where your CD-Rom drive is located) and click OK. Upon completion, go to Program Files -> Web Management Utility and execute the Web Management utility. Web Management Utility
The Web Management Utility was divided into four parts, Discovery List, Monitor List, Device Setting and Toolbar function, for details instruction, follow the below section.
Discovery List
This is the list where you can discover all the Web management devices in the entire network. By pressing the "Discovery" button, you can list all the Web Management devices in the discovery list. Double click or press the "Add to monitor list" button to select a device from the Discovery List to the Monitor List.
19
System word definitions in the Discovery List: MAC Address: Shows the device MAC Address. Gateway: Shows the Gateway set of the device.
Monitor List
All the Web Smart Device in the Monitor List can be monitored; you can also receive the trap and show the status of the device. System word definitions in the Monitor List: S: Shows the system symbol of the Web-Smart device, represent for device system is not alive. 20
View Trap: The Trap function can receive the events that happen from the Web Management Switch in the Monitor List. There is a light indicator behind the "View Trap" button, when the light indicates in green, it means that there is no trap transmitted, and else when it indicates in red, it means that there is new trap transmitted, this is to remind us to view the trap. [. . . ] The Login Timeout controls the idle time-out for security purposes, when there is no action in the Web-based Utility. When the Login Timeout expires, the Web based Utility requires a re-login before using the Utility again.
Figure 38. System Setting
45
Trap Setting By configuring the Trap Setting, it allows Web Management Utility to monitor specified events on this Web-Smart Switch. When the Trap Setting is Enabled, enter the Destination IP address of the managing PC that will receive trap information.
Figure 39. [. . . ]