User manual EINHELL RG-SP 300
DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual EINHELL RG-SP 300. We hope that this EINHELL RG-SP 300 user guide will be useful to you.
You may also download the following manuals related to this product:
EINHELL RG-SP 300 (785 ko)
EINHELL RG-SP 300 (785 ko)
EINHELL RG-SP 300 (785 ko)
EINHELL RG-SP 300 (785 ko)
EINHELL RG-SP 300 (785 ko)
EINHELL RG-SP 300 (785 ko)
EINHELL RG-SP 300 DATASHEET (5185 ko)
EINHELL RG-SP 300 DATASHEET (4189 ko)
Manual abstract: user guide EINHELL RG-SP 300
Detailed instructions for use are in the User's Guide.
[. . . ] This equipment is not designed to be used by people (including children) with limited physical, sensory or mental capacities or those with no experience and/or knowledge unless they are supervised by a person who is responsible for their safety or they have received instructions from such a person in how to use the equipment safely. Children must always be supervised in order to ensure that they do not play with the equipment. Before you put the equipment into operation, arrange for a specialist to check that the - earthing - protective multiple earthing - residual-current operated circuit-breaker circuit comply with the safety regulations of the power supply company and work correctly. The electrical plug-in connections must be protected from wet conditions. [. . . ] Setting the ON/OFF switching point: The ON/OFF switching point can be infinitely adjusted with the height adjustment facility. The floating switch must be fitted so that the switching point height: ON and the switch point height: OFF can be reached easily and with little force. Check this by placing the equipment in a container filled with water and carefully raising and lowering the floating switch with your hand. Make sure that the distance between the floating switch head and the cable holder is not too small. If the distance is too small, there is no guarantee that the equipment will work correctly. When adjusting the floating switch, make sure Before putting the equipment into operation 5. 1 Installation The equipment can be installed either: Stationary with rigid tubing or Stationary with a flexible hose line Note: The maximum pumping rate is possible only with the largest possible line diameter; if smaller hoses or tubes are connected, the pumping rate will be reduced. 4) to the connection actually used in order not to reduce the pumping rate unnecessarily. Flexible hoses must be fastened to the universal hose connection with a hose clip (not included in the scope of supply). When installing, never hang the equipment by the discharge line or by the power cable. The equipment must be hung up with the provided carry handle or it must rest on the bottom of the shaft. To ensure that the equipment works properly, the bottom of the shaft always must be free of sludge and other accumulations of dirt. If the water level is too low, the sludge in the shaft can quickly dry out and hinder the equipment from starting. That the floating switch does not touch the bottom before the equipment is switched off. manual operation: Mount the float switch as illustrated in Figure 3 so that the device runs continuously. In this mode the equipment may be used only under supervision to avoid dry running. The equipment must be switched off (pull out the power plug) as soon as no more water is emitted from the discharge line. 3 Ordering replacement parts: Please quote the following data when ordering replacement parts: Type of machine Article number of the machine Identification number of the machine Replacement part number of the part required For our latest prices and information please go to www. If the power cable for this equipment is damaged, it must be replaced by the manufacturer or its aftersales service or similarly trained personnel to avoid danger. The unit is supplied in packaging to prevent its being damaged in transit. This packaging is raw material and can therefore be reused or can be returned to the raw material system. The unit and its accessories are made of various types of material, such as metal and plastic. [. . . ] Please note that our devices have not been designed for use in commercial, trade or industrial applications. Consequently, the guarantee is invalidated if the equipment is used in commercial, trade or industrial applications or for other equivalent activities. The following are also excluded from our guarantee: compensation for transport damage, damage caused by failure to comply with the installation/assembly instructions or damage caused by unprofessional installation, failure to comply with the operating instructions (e. Connection to the wrong mains voltage or current type), misuse or inappropriate use (such as overloading of the device or use of non-approved tools or accessories), failure to comply with the maintenance and safety regulations, ingress of foreign bodies into the device (e. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE EINHELL RG-SP 300
Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual EINHELL RG-SP 300 will begin.