User manual CINO FUZZYSCAN WIRELESS IMAGER REFERENCE MANUAL REV A7

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual CINO FUZZYSCAN WIRELESS IMAGER. We hope that this CINO FUZZYSCAN WIRELESS IMAGER user guide will be useful to you.


CINO FUZZYSCAN WIRELESS IMAGER REFERENCE MANUAL REV A7: Download the complete user guide (1008 Ko)

Manual abstract: user guide CINO FUZZYSCAN WIRELESS IMAGERREFERENCE MANUAL REV A7

Detailed instructions for use are in the User's Guide.

[. . . ] A1 Oct 22, 2009 Page 6 Page 68 Revise "Clone Function" operation method. Add "Save Configuration" and "Master Default" to System Commands. Page 53 Rev. A2 Nov 27, 2009 Page 69 "Bluetooth Device Name" ­ Modify user define characters from 1 ­ 14 characters to 1 ­ 16 characters. A3 Mar 05, 2010 Page 25 Page 43 Page 45 Page 48 Page 49 Modify UPC-E/EAN-8 expansion and UPC-A standardization. [. . . ] But if you select the " Auto ", FuzzyScan will terminate this Reference Manual selection automatically. Wireless FuzzyScan If your application is known, you may select those known symbologies only to increase the reading speed and decrease the possibility of reading error. Furthermore, to add the "Symbology ID" into the transmitted data is also helpful to identify the specific symbology. When you select "Auto", the scanner only read those symbologies marked with * When you set the minimum and maximum length of each symbology, please note the data length of scanned bar code doesn't include star/stop characters. 21 Configure Your FuzzyScan Symbology Reading Control Code 39/Code 32 Setting PROGRAM F_DEFAULT Family Code Selection P. C SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS Parameter Selection Disable Code 39 Enable Code 39 Select Standard Code 39 as primary format Select Full ASCII Code 39 as primary format Select Code 32 (PARAF, Italian Pharmaceutical) as primary format Disable start/stop symbol transmission Enable start/stop symbol transmission Disable Code 32 leading A transmission Enable Code 32 leading A transmission Disable MOD 43 check digit verification Enable MOD 43 check digit verification Disable check digit transmission Enable check digit transmission Disable Code 39 buffering Enable Code 39 buffering Option Code 0 1 2 3 4 5 6 7 8 9 A B C D E Code 39 Family Setting Trioptic Code 39 Setting Reference Manual SS SS Disable Trioptic Code 39 Enable Trioptic Code 39 0 1 Wireless FuzzyScan Code 39 Min. Length SS MS Default (01) 01-Maximum FIN (2 digits) Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically. Code 39 Max. Length SS MS Default (98) 98-Minimum FIN (2 digits) Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically. Trioptic Code 39 and Code 39 Full ASCII cannot be enabled simultaneously. 22 Configure Your FuzzyScan Symbology Reading Control Codabar/NW-7 Setting PROGRAM F_DEFAULT Family Code Selection P. C SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS Parameter Selection Disable Codabar Enable Codabar Select Codabar standard format Select Codabar ABC format Select Codabar CLSI format Select Codabar CX format Disable start/stop symbol transmission Enable ABCD/ABCD start/stop symbol transmission Enable abcd/abcd start/stop symbol transmission Enable ABCD/TN*E start/stop symbol transmission Enable abcd/tn*e start/stop symbol transmission Disable check digit verification Enable check digit verification Disable check digit transmission Enable check digit transmission Option Code 0 1 2 3 4 5 6 7 8 9 A B C D E Codabar Setting Reference Manual Codabar Min. Length SS MS Default (04) 01-Maximum FIN (2 digits) Wireless FuzzyScan Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically. Codabar Max. Length SS MS Default (98) 98-Minimum FIN (2 digits) Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically. 23 Configure Your FuzzyScan Symbology Reading Control UPC-A & UPC-E Setting PROGRAM F_DEFAULT Family Code Selection P. C SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS Parameter Selection Disable UPC-A Enable UPC-A Disable UPC-E Enable UPC-E Disable UPC-E expansion Enable UPC-E expansion Disable UPC standardization Enable UPC standardization Disable UPC numeric system Enable UPC numeric system Disable UPC-A check digit transmission Enable UPC-A check digit transmission Disable UPC-E check digit transmission Enable UPC-E check digit transmission Disable UPC "leading 1" portion Enable UPC "leading 1" portion Option Code 0 1 2 3 4 5 6 7 8 9 A B C D E F UPC Family Setting Reference Manual Wireless FuzzyScan When enable UPC-E expansion, the UPC-E decoded data will be converted to UPC-A format and affected by related setting, such as UPC standardization, UPC numeric system, UPC-A check digit transmission. UPC-E & EAN-8 Expansion : Expand the 8-digit UPC-E and 8-digit ENA-8 to 12-digit UPC-A and 13-digit EAN-13. UPC-A/E Standardization : Expand the 12-digit UPC-A to 13-digit EAN-13 with 1 zero insertion. UPC Lead 1 Numeric System : Enable to read UPC leading with the 1 numeric system, you must enable this option. WPC Selection (UPC/EAN/CAN) Basic Length Disable Check Digit Disable Numeric System With 2-digit Addendum With 5-digit Addendum Enable Standardization Enable Expansion UPC-A UPC-E EAN-13 EAN-8 12 8 13 8 -1 -1 -1 -1 -1 -1 NC NC +2 +2 +2 +2 +5 +5 +5 +5 +1 +1 NC NC 0 +4 0 +5 24 Configure Your FuzzyScan Symbology Reading Control UPC-A & UPC-E Setting PROGRAM F_DEFAULT Family Code Selection P. C SS SS SS SS SS SS SS SS Parameter Selection Select UPC without supplement digits Select UPC with only 2 supplement digits Select UPC with only 5 supplement digits Select UPC with 2/5 supplement digits Disable force supplement digits output Enable force supplement digits output UPC Family Addenda Separator Off UPC Family Addenda Separator On Option Code 0 1 2 3 4 5 6 7 UPC Supplement Setting UPC/EAN Security Level SS SS SS Level 0 Level 1 Level 2 0 1 2 Only available for UPC-A & EAN-13 Supplement Scan Voting Reference Manual Wireless FuzzyScan UPC/EAN Security Level The scanner offers three levels of decode security for UPC/EAN bar codes: Level 0: If you are experiencing misread of poorly-printed or out-of-spec. bar codes, especially in characters 1, 2, 7, and 8 in level 1, please select level 0. Selection of this security level may significantly impair the decoding ability of the scanner. Level 1: This is the default setting which allows the scanner to operate fastest, while providing sufficient security in decoding "in-spec" UPC/EAN bar codes. Level 2: If you are experiencing misread of poorly-printed, soiled or damage bar codes in level 1, please select level 2. The Supplement Scan Voting is the number of times the same UPC/EAN with 2/5 supplement digits has to be decoded before it is transmitted. It is helpful when decoding a mix of UPC/EAN symbols with and without supplement digits. This function is effective when you select UPC/EAN with only 2 supplement digits, UPC/EAN with only 5 supplement digits or UPC/EAN with 2/5 supplement digits. When you select higher level, it may impact the reading speed on poorly-printed, low contrast or damage barcode labels. 25 SS SS SS SS SS SS SS None Level 1 Level 2 Level 3 Level 4 Level 5 Level 6 Level 7 Level 8 Level 9 Level 10 Level 11 Level 12 Level 13 0 1 2 3 4 5 6 7 8 9 A B C D Configure Your FuzzyScan Symbology Reading Control EAN Setting PROGRAM F_DEFAULT Family Code Selection P. C SS SS SS SS SS SS SS SS SS SS SS SS Parameter Selection Disable EAN-13 Enable EAN-13 Disable EAN-8 Enable EAN-8 Disable EAN-8 expansion Enable EAN-8 expansion Disable EAN-13 check digit transmission Enable EAN-13 check digit transmission Disable EAN-8 check digit transmission Enable EAN-8 check digit transmission Disable ISBN/ISSN Conversion reading check Enable ISBN/ISSN Conversion reading check Option Code 0 1 2 3 4 5 6 7 8 9 A B EAN Setting EAN Supplement Setting Reference Manual Wireless FuzzyScan SS SS SS SS SS SS SS SS Select EAN without supplement digits Select EAN with only 2 supplement digits Select EAN with only 5 supplement digits Select EAN with 2/5 supplement digits Disable force supplement digits output Enable force supplement digits output EAN Addenda Separator Off EAN Addenda Separator On 0 1 2 3 4 5 6 7 Supplement Scan Voting The Supplement Scan Voting is the number of times the same UPC/EAN with 2/5 supplement digits has to be decoded before it is transmitted. It is helpful when decoding a mix of UPC/EAN symbols with and without supplement digits. This function is effective when you select UPC/EAN with only 2 supplement digits, UPC/EAN with only 5 supplement digits or UPC/EAN with 2/5 supplement digits. When you select higher level, it may impact the reading speed on poorly-printed, low contrast or damage barcode labels. 26 SS SS SS SS SS SS SS None Level 1 Level 2 Level 3 Level 4 Level 5 Level 6 Level 7 Level 8 Level 9 Level 10 Level 11 Level 12 Level 13 0 1 2 3 4 5 6 7 8 9 A B C D Configure Your FuzzyScan Symbology Reading Control EAN Setting PROGRAM F_DEFAULT Family Code Selection P. C SS SS SS Level 0 Level 1 Level 2 Parameter Selection Option Code 0 1 2 UPC/EAN Security Level Only available for UPC-A & EAN-13 EAN Supplement Control SS SS SS SS SS SS SS SS Disable all specific prefix supplement digital output Enable all specific prefix supplement digital output Enable 491 Supplement Digit Output Enable 978/979 Supplement Digit Output Enable 977 Supplement Digit Output Enable 378/379 Supplement Digit Output Enable 414/419 Supplement Digit Output Enable 434/439 Supplement Digit Output 0 1 2 3 4 5 6 7 Reference Manual Wireless FuzzyScan UPC/EAN Security Level The scanner offers three levels of decode security for UPC/EAN bar codes: Level 0: If you are experiencing misread of poorly-printed or out-of-spec. bar codes, especially in characters 1, 2, 7, and 8 in level 1, please select level 0. [. . . ] The date code output should skip "9" and replaced it by "A". Test Bar Code : 9 8 1 0 2 5 1 2 3 4 5 6 9 8 7 6 EAN-8 : 05 Code 93 : 09 UCC/EAN 128 : 31 EAN-8 with 2 supple : 35 Code 11 : 10 UPC-A : 02 EAN-8 with 5 supple. : 45 MSI/Plessey : 11 UPC-A with 2 supple. : 32 Codabar/NW-7 : 06 UK/Plessey : 12 UPC-A with 5 supple. : 42 Code 39 : 07 Telepen : 13 UPC-E : 03 Code 32 : 37 GS1 Data Bar : 14 UPC-E with 2 supple. : 33 Trioptic Code 39: 47 IATA : 15 UPC-E with 5 supple. : 43 Matrix 2 of 5 : 38 Coupon Code : 16 EAN-13 : 04 Interleaved 2 of 5 : 48 PDF417/MicroPDF417: 22 EAN-13 with 2 supple. : 34 China Postal Code : 58 Codablock: 23 EAN-13 with 5 supple. : 44 German Postal Code : 68 Korea Post Code: 26 Reference Manual Wireless FuzzyScan Position Calculation [Data Formatter] If there is a 5-character input data string, refer to the following to calculate the actual position for insertion: X X X X X 00 01 02 03 04 05 Actual Output : A81025[TAB]SN123456[TAB]76[TAB] 62 Configure Your FuzzyScan Programming Procedure [Data Verifier] Scan "Program" to enter the programming mode. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CINO FUZZYSCAN WIRELESS IMAGER




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual CINO FUZZYSCAN WIRELESS IMAGER will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.