User manual CINO FUZZYSCAN BARCODE IMAGER PROGRAMMING REV B8

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual CINO FUZZYSCAN BARCODE IMAGER. We hope that this CINO FUZZYSCAN BARCODE IMAGER user guide will be useful to you.


CINO FUZZYSCAN BARCODE IMAGER PROGRAMMING REV B8: Download the complete user guide (683 Ko)

You may also download the following manuals related to this product:

   CINO FUZZYSCAN BARCODE IMAGER PROGRAMMING MANUAL REV B9 (680 ko)

Manual abstract: user guide CINO FUZZYSCAN BARCODE IMAGERPROGRAMMING REV B8

Detailed instructions for use are in the User's Guide.

[. . . ] 16, 2009 May 05, 2009 First Release Page 22 Page 25 Page 46 Rev. B1 June 22, 2009 Page 34 Page 37 Code 128/EAN-128 Setting ­ Modify ISBT Concatenation Off option code to "4" and ISBT Concatenation On option code to "5". GS1 Databar Setting ­ All GS1 databar default values are changed to Enable. 21, 2009 Programming Manual Page 9, 11 Add "PDF417/Micro PDF417", "Codablock F", "Korea Post Code". Page 26 Add "Composite Code Setting", "PDF/Micro PDF417 Setting", "Codablock F Setting", Korea Post Code Setting". [. . . ] Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically. FIN (2 digits) Interfunction Delay SS MS None 1-99 (x5) msec. Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically. FIN (2 digits) Programming Manual Intermessage Delay is a time delay between messages output by FuzzyScan. Increasing this delay will help host applications process the incoming data on time. Intercharacter Delay is a time delay between data characters output by FuzzyScan. These two parameters are used to synchronize data communication when : 1) the data transmission speed is too fast, characters may be skipped; 2) multitasking operation system or host computers in a network may slow down the keyboard handling; 3) various notebook or desktop PC systems require different timing parameter settings. Please always add one extra unit as safety margin when adjusting these two parameters. Interfunction Delay is a time delay between the transmission of each segment of the message string. FuzzyScan 30 Configure Your FuzzyScan Keyboard Interface Control Emulation Setting & Upper/Lower Case Setting PROGRAM Family Code Selection Function Key Emulation P. C SS SS F_DEFAULT Parameter Selection Enable ASCII 00-31 code as keyboard function code output Ctrl-Output Refer to Appendix ­ Keyboard Function Code Table for details. Option Code 0 1 Key Pad Emulation SS SS Disable key pad emulation Enable numeric output as key pad (Num Lock On) output 0 1 Upper/Lower Case Programming Manual SS SS SS SS Normal case (neglect the upper/lower case control) Inverse case (change all characters output to inverse case) Upper case (force all characters output as upper case) Lower case (force all characters output as lower case) 0 1 2 3 FuzzyScan 31 Configure Your FuzzyScan Serial Interface Control Record Suffix, Preamble , Postamble Setting PROGRAM Family Code Selection STX/ETX Control P. C SS SS F_DEFAULT Parameter Selection Disable STX/ETX transmission Enable STX/ETX transmission STX/ETX are two characters used to indicate the starting and ending of the total data frame transmitted via serial interface. Option Code 0 1 Record Suffix SS SS SS SS SS SS MS SS MS None CR (0DH) LF (0AH) CRLF (0D0AH) TAB (09H) SPACE (20H) User defined character (1 character) None 1-15 characters Maximum 15-character input; scan "FIN" to terminate this selection. 0 1 2 3 4 5 6, (00-7F) FIN [00-7F], [FIN] Programming Manual Preamble Postamble SS MS None 1-15 characters Maximum 15-character input; scan "FIN" to terminate this selection. FIN [00-7F], [FIN] Serial Interface Message String (RS232, USB COM) : STX 1 character Preamble 1-15 characters Data Length 2-3 digits Prefix Symbol ID 1 or 2 characters Scanned Data Variable length Suffix Symbol ID 1 or 2 characters Postamble 1-15 characters ETX 1 character Record Suffix 1 character FuzzyScan 32 Configure Your FuzzyScan Serial Interface Control Delay Setting PROGRAM Family Code Selection Intermessage Delay P. C SS MS None 1-99 (x5) msec. Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically. F_DEFAULT Parameter Selection Option Code FIN (2 digits) Intercharacter Delay SS MS None 1-99 (x5) msec. Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically. FIN (2 digits) Interfunction Delay SS MS None 1-99 (x5) msec. Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically. FIN (2 digits) Programming Manual Intermessage Delay is a time delay between messages output by FuzzyScan. Increasing this delay will help host applications process the incoming data on time. Intercharacter Delay is a time delay between data characters output by FuzzyScan. These two parameters are used to synchronize data communication when : 1) the data transmission speed is too fast, characters may be skipped; 2) multitasking operation system or host computers in a network may slow down the keyboard handling; 3) various notebook or desktop PC systems require different timing parameter settings. Please always add one extra unit as safety margin when adjusting these two parameters. Interfunction Delay is a time delay between the transmission of each segment of the message string. FuzzyScan 33 Configure Your FuzzyScan Serial Interface Control Protocol, Baud Rate, Data Frame & Time Out Setting PROGRAM Family Code Selection Handshaking Protocol P. C SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS MS F_DEFAULT Parameter Selection None (free running mode) RTS/CTS (hardware handshaking) ACK/NAK (software handshaking) Xon/Xoff (software handshaking) 38. 4K BPS 19. 2K BPS 9600 BPS 4800 BPS 2400 BPS 8, None, 1 8, Odd, 1 8, Even, 1 8, Space, 1 8, Mark, 1 8, None, 2 7, Odd, 1 7, Even, 1 None 200 mseconds 500 mseconds 1200 BPS 600 BPS 300 BPS 57. 6K BPS 115. 2K BPS 7, Space, 1 7, Mark, 1 7, None, 2 7, Odd, 2 7, Even, 2 7, Space, 2 7, Mark, 2 1 second 2 seconds 5 seconds User defined value (seconds) 0 1 2 3 4 0 1 2 3 4 5 6 7 0 1 2 Option Code 0 1 2 3 5 6 7 8 9 8 9 A B C D E 3 4 5 6, (2 digits) Baud Rate (BPS) Data Frame Programming Manual Serial Response Time-out FuzzyScan When the RTS/CTS Hardware Handshaking option is selected, the RTS (request to send) and CTS (clear to send) signals will be issued before normal data communication. This option is very helpful to ensure the reliability of data communication. When the ACK/NAK Software Handshaking option is selected, the FuzzyScan waits for an ACK (acknowledge) or NAK (not acknowledge) from the host computer after each data transmission. If the NAK is received, FuzzyScan will re-send the data until receiving ACK. The Serial Response Time-out is a pre-defined delay time for FuzzyScan to wait for handshaking, acknowledgment or non-acknowledgment from the host computer. 34 Configure Your FuzzyScan Wand/Laser Emulation Control Output Polarity, Signal State, Margin/Module Time, etc. PROGRAM Family Code Selection Output Polarity P. C SS SS F_DEFAULT Parameter Selection High level (5Vdc) on Bar (low level on Space) Low level (0Vdc) on Bar (high level on Space) Determine the output voltage level for both bar and space. Option Code 0 1 Initial Signal State SS SS High Level (5Vdc) Low Level (0Vdc) Determine the initial state of output voltage level. 0 1 Margin Time SS SS SS SS SS SS SS 10 msec. Delay time before data transmission Long Time base of minimum narrow bar 0 1 2 3 0 1 2 4 5 6 Programming Manual Module Time 3 Narrow/Wide Ratio SS SS SS 1:2 1:2. 5 1:3 0 1 2 Code 39/Code 128 Emulation FuzzyScan SS SS SS SS SS Disable standard Code 39 emulation Enable standard Code 39 skip emulation Enable standard Code 39 replace emulation Enable Full ASCII Code 39 emulation Enable Code 128 emulation 0 1 2 3 4 [ Code 39 Skip] : When this option is selected, all scanned data will be translated as Standard Code 39 wand/laser emulation output. If any lower case characters are read, they will be translated to upper case characters. [. . . ] Scan "Identified Data Length" and set the length to "16". Scan "1st Identified Character" and set the identified position to "00", then set the identified character to "39" (Hex Code of 9). [Data Replacer] Scan "Replacer Control" and set bar code symbology to "48". Scan "1st Replacement" and set the identified position to "00", then replaced character to "41" (Hex Code of A). [Data Organizer] Scan "Organizer Control" and set bar code symbology to "48". Scan "1st Organization" and set the identified position to "16", then set the data transmission to "0" (forward). [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CINO FUZZYSCAN BARCODE IMAGER




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual CINO FUZZYSCAN BARCODE IMAGER will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.