User manual CANON XEED SX6000 BROCHURE

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual CANON XEED SX6000. We hope that this CANON XEED SX6000 user guide will be useful to you.


CANON XEED SX6000 BROCHURE: Download the complete user guide (254 Ko)

You may also download the following manuals related to this product:

   CANON XEED SX6000 BROCHURE (254 ko)
   CANON XEED SX6000 BROCHURE (253 ko)
   CANON XEED SX6000 BROCHURE (252 ko)
   CANON XEED SX6000 BROCHURE (251 ko)
   CANON XEED SX6000 BROCHURE (257 ko)
   CANON XEED SX6000 BROCHURE (257 ko)
   CANON XEED SX6000 BROCHURE (247 ko)
   CANON XEED SX6000 BROCHURE (255 ko)
   CANON XEED SX6000 BROCHURE (250 ko)
   CANON XEED SX6000 BROCHURE (249 ko)
   CANON XEED SX6000 BROCHURE (249 ko)
   CANON XEED SX6000 BROCHURE (249 ko)

Manual abstract: user guide CANON XEED SX6000BROCHURE

Detailed instructions for use are in the User's Guide.

[. . . ] Combining the benefits of Canon's LCOS panel technology with extremely bright, high resolution imaging ­ up to industry-leading, native WUXGA resolution (1920 x 1200 pixels) ­ XEED offers seamless projection and optimal reproduction of X-ray images. [. . . ] At in-hospital conferences and in the university classroom, Canon XEED projectors are a valuable addition to any PACS (Picture Archiving and Communication System), providing a reliable platform for radiological case discussions. Without DICOM simulation mode With DICOM simulation mode OUT-OF-THE-BOX DICOM SIMULATION Optimising images to human visual perception, the DICOM 14 standard sets the benchmark in digital radiology. Canon XEED Projector WUX10 / XEED SX7 Mark II Medical / XEED SX80 Mark II Medical RS232 control cable The XEED WUX10 Mark II Medical, XEED SX7 Mark II Medical and XEED SX80 Mark II Medical all offer a DICOM simulation mode as standard. * This DICOM SIM mode features 21 different levels of greyscale reproduction, based on combinations of maximum luminance and contrast. The result is a flexible solution that can be used in varying lighting conditions. In addition, the range of DICOM presets available makes it far easier to accurately match twin screens when required. AcuScreenPRO software PC/ Laptop with USB and RS232 interface Measuring sensor Tripod USB Connection The AcuScreenPRO system is comprised of easy-to-use, PC-based software and a measuring sensor. The supplied luminance meter is used to evaluate exact display conditions, allowing precise corrections to be made according to the specific environment. Combining LCOS technology and native SXGA+ resolution, the efficient comparative study of X-ray images plays a large role in shortening diagnostic processes ­ benefiting both patients and hospital staff. Canon XEED projectors have been installed in many similar situations, having been selected by the industry's leading medical system integrators as their projection solution of choice for this type of application. SPECIFICATIONS LCD PANEL Type Aspect Ratio Native Resolution OPTICS Zoom Magnification and Control Lens Shift IMAGE AND AUDIO Brightness Contrast Ratio Keystone Correction Range Display Modes LCOS reflective display, TFT Active Matrix 16:10 1920 x 1200 (WUXGA), 2304000 pixels LCOS reflective display, TFT Active Matrix 4:3 1400 x 1050 (SXGA+), 1470000 pixels LCOS reflective display, TFT Active Matrix 4:3 1400 x 1050 (SXGA+), 1470000 pixels 1. 5x Motorised 10:0 (fixed) 1. 7x Motorised 9:1 (fixed) 1. 5x Motorised 10:0 (fixed) 3200 lumens 1000:1 (full on / full off) Vertical: +/- 20° (Auto / Manual) Standard, Presentation, Movie, sRGB, Photo, DICOM SIM 4000 lumens 1000:1 (full on / full off) Vertical: +/- 20° (Auto / Manual), Horizontal: +/- 20° (Manual) Standard, Presentation, Movie, Adobe RGB, sRGB, Photo, DICOM SIM 3000 lumens 900:1 (full on / full off) Vertical: +/- 20° (Auto / Manual) Standard, Presentation, Movie, sRGB, Photo, DICOM SIM PORTS AND CONNECTORS Digital RGB / Analogue RGB Digital Video and Audio Input Analogue RGB Input 2 Analogue RGB Output S-Video Input Composite Video Input Audio Input 1, Input 2, Input 3 Audio Output Service Port / Projector Control Network Port RATINGS Dimensions (W x H x D) Weight Power Consumption Noise Level Warranty DVI-I 29-pin (HDCP compatible) HDMI V1. 3 with Deep Colour Mini D-Sub 15-pin (Component via supplied adaptor cable) Mini D-Sub 15-pin (shared with Analogue RGB Input 2) Mini-DIN 4-pin RCA x 1 3. 5mm stereo mini-jack x 3 3. 5mm stereo mini-jack x 1 (variable level) Mini D-Sub 9-pin RJ-45 DVI-I 29-pin (HDCP compatible) -- Mini D-Sub 15-pin (Component via supplied adaptor cable) Mini D-Sub 15-pin Mini-DIN 4-pin RCA x 1 3. 5mm stereo mini-jack x 3 3. 5mm stereo mini-jack x 1 (variable level) Mini-DIN 8-pin Via optional RS-NA01 network adaptor DVI-I 29-pin (HDCP compatible) HDMI V1. 3 with Deep Colour Mini D-Sub 15-pin (Component via supplied adaptor cable) Mini D-Sub 15-pin Mini-DIN 4-pin RCA x 1 3. 5mm stereo mini-jack x 3 3. 5mm stereo mini-jack x 1 (variable level) Mini D-Sub 9-pin RJ-45 284mm x 114mm x 336mm 5. 0kg Normal Mode: 400W / Quiet Mode: 330W / Standby: 11W Normal Mode: 36dBA / Quiet Mode: 32dBA 3 years 266mm x 114mm x 336mm 4. 8kg Normal Mode: 360W / Quiet Mode: 290W / Standby: 7W Normal Mode: 35dBA / Quiet Mode: 31dBA 3 years 332mm x 121mm x 340mm 5. 0kg Normal Mode: 330W / Quiet Mode: 270W / Standby: 15W Normal Mode: 35dBA / Quiet Mode: 31dBA 3 years All data is based on Canon's standard testing methods. This Leaflet and the specifications of the product have been developed prior to the date of product launch. TMand ®: All company and/or product names are trademarks and/or registered trademarks of their respective manufacturers in their markets and/or countries. System Architecture ­ Integration of XEED with a typical PACS System True Throw Distances WUX10 MARK II MEDICAL Image size (inches) Width (cm) Height (cm) Projection distance (zoom max) 40 90 50 1. 2m (3. 9") 1. 8m (5. 9") 60 130 80 1. 8m (5. 9") 80 170 110 2. 4m (7. 9") 100 220 130 150 320 200 180 390 240 200 430 270 250 540 340 300 650 400 Screen Sensor 3. 0m 4. 5m 5. 4m 6. 1m 7. 6m 9. 1m (9. 8") (14. 8") (17. 7") (20. 0") (24. 9") (29. 9") -- -- Projector RS 232 Projector Diagnostic monitor Projection distance (zoom min) 2. 6m 3. 5m 4. 4m 6. 7m 8. 0m 8. 9m (8. 5") (11. 5") (14. 4") (22. 0") (26. 3") (29. 2") SX7 MARK II MEDICAL DVI Cable DVI Cable DVI Splitter DVI Splitter Work Station Laptop/PC PACS Image size (inches) Width (cm) Height (cm) Projection distance (zoom max) Projection distance (zoom min) 40 81 61 1. 2m (3. 9") 2. 0m (6. 6") 60 122 91 1. 8m (5. 9") 2. 9m (9. 5") 80 163 122 2. 4m (7. 9") 3. 9m (12. 8") 100 203 152 3. 0m (9. 8") 4. 9m (16. 1") 150 305 229 4. 5m (14. 8") 7. 4m (24. 3") 200 406 305 5. 9m (19. 4") -- 300 610 457 9. 1m (29. 9") -- SX80 MARK II MEDICAL Image size (inches) Width (cm) Height (cm) Projection distance (zoom max) Projection distance (zoom min) 40 80 60 1. 2m (3. 9") 1. 7m (5. 6") 60 120 90 1. 8m (5. 9") 80 160 120 2. 4m (7. 9") 100 200 150 150 300 230 180 370 270 200 410 300 250 510 380 300 610 460 3. 0m 4. 5m 5. 4m 6. 0m 7. 6m 9. 1m (9. 8") (14. 8") (17. 7") (19. 7") (24. 9") (29. 9") -- -- 2. 6m 3. 5m 4. 4m 6. 6m 8. 0m 8. 9m (8. 5") (11. 5") (14. 4") (21. 7") (26. 3") (29. 2") www. canon. com/lcd-sim Canon Inc. [. . . ] TMand ®: All company and/or product names are trademarks and/or registered trademarks of their respective manufacturers in their markets and/or countries. System Architecture ­ Integration of XEED with a typical PACS System True Throw Distances WUX10 MARK II MEDICAL Image size (inches) Width (cm) Height (cm) Projection distance (zoom max) 40 90 50 1. 2m (3. 9") 1. 8m (5. 9") 60 130 80 1. 8m (5. 9") 80 170 110 2. 4m (7. 9") 100 220 130 150 320 200 180 390 240 200 430 270 250 540 340 300 650 400 Screen Sensor 3. 0m 4. 5m 5. 4m 6. 1m 7. 6m 9. 1m (9. 8") (14. 8") (17. 7") (20. 0") (24. 9") (29. 9") -- -- Projector RS 232 Projector Diagnostic monitor Projection distance (zoom min) 2. 6m 3. 5m 4. 4m 6. 7m 8. 0m 8. 9m (8. 5") (11. 5") (14. 4") (22. 0") (26. 3") (29. 2") SX7 MARK II MEDICAL DVI Cable DVI Cable DVI Splitter DVI Splitter Work Station Laptop/PC PACS Image size (inches) Width (cm) Height (cm) Projection distance (zoom max) Projection distance (zoom min) 40 81 61 1. 2m (3. 9") 2. 0m (6. 6") 60 122 91 1. 8m (5. 9") 2. 9m (9. 5") 80 163 122 2. 4m (7. 9") 3. 9m (12. 8") 100 203 152 3. 0m (9. 8") 4. 9m (16. 1") 150 305 229 4. 5m (14. 8") 7. 4m (24. 3") 200 406 305 5. 9m (19. 4") -- 300 610 457 9. 1m (29. 9") -- SX80 MARK II MEDICAL Image size (inches) Width (cm) Height (cm) Projection distance (zoom max) Projection distance (zoom min) 40 80 60 1. 2m (3. 9") 1. 7m (5. 6") 60 120 90 1. 8m (5. 9") 80 160 120 2. 4m (7. 9") 100 200 150 150 300 230 180 370 270 200 410 300 250 510 380 300 610 460 3. 0m 4. 5m 5. 4m 6. 0m 7. 6m 9. 1m (9. 8") (14. 8") (17. 7") (19. 7") (24. 9") (29. 9") -- -- 2. 6m 3. 5m 4. 4m 6. 6m 8. 0m 8. 9m (8. 5") (11. 5") (14. 4") (21. 7") (26. 3") (29. 2") www. canon. com/lcd-sim Canon Inc. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CANON XEED SX6000




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual CANON XEED SX6000 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.