User manual CANDY CFX 64 P

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual CANDY CFX 64 P. We hope that this CANDY CFX 64 P user guide will be useful to you.


CANDY CFX 64 P : Download the complete user guide (2924 Ko)

Manual abstract: user guide CANDY CFX 64 P

Detailed instructions for use are in the User's Guide.

[. . . ] CAUTION: In order to avoid a hazard due to inadvertent resetting of the thermal cutout, this appliance must not be supplied through an external switching device, such as a timer, or connected to a circuit that is regularly switched on and off by the utility. This appliance must be installed in accordance with the regulations in force and only used in a well ventilated space. "These instructions are only valid if the country symbol appears on the appliance. If the symbol does not appear on the appliance, it is necessary to refer to the technical instructions which will provide the necessary instructions concerning modification of the appliance to the conditions of use of the country". [. . . ] For this reason you should ensure good ventilation either by keeping all natural air passages open or by installing an extractor hood with an exhaust flue. Intensive and prolonged use of the appliance may require extra ventilation, such as the opening of a window or an increase in speed of the electric fan, if you have one. If a hood can not be installed, an electric fan should be fitted to an outside wall or window to ensure that there is adequate ventilation. The electric fan should be able to carry out a complete change of air in the kitchen 3-5 times every hour. Warning - this appliance must be earthed This appliance is designed for domestic use only. Connection to the main supply must be made by a competant electrician, ensuring that all current regulations concerning such installations are observed. The appliance must only be connected to a suitably rated spur point, a 3 pin 13 amp plug/socket is not suitable. A double pole switch must be provided and the circuit must have appropriate fuse protection. Further details of the power requirement of the individual product will be found in the users' instruction and on the appliance rating plate. In the case of built-in product you are advised, should you wish to use a longer cable than the one supplied, that a suitably rated heat resistant type must be used. The wiring must be connected to the mains supply as follows: If an appliance is not fitted with a supply cord and a plug, or with other means for disconnection from the supply mains having a contact separation in all poles that provide full disconnection under overvoltage category III conditions, the instructions shall state that means for disconnection must be incorporated in the fixed wiring in accordance with the wiring rules. These instructions are for qualified personnel, installation of equipment must be in line with the relevant national standard. Only: by law the gas installation\commissioning must be carried out by a "Gas Safe" installer) All work must be carried out with the electricity supply disconnected. The rating plate on the hob shows the type of gas with which it is designed to be used. Connection to the mains gas supply or gas cylinder should be carried out after having checked that it is regulated for the type of gas with which it will be supplied. Use only pipes, washers and sealing washers which comply with the relevant national standards. For some models a conic link is furnished to outfit for the installation in the countries where this type of link is obligatory; in picture 8 it is pointed out how to recognize the different types of links (CY = cylindrical, CO = conic). In every case the cylindrical part of the link has to be connected to the hob. When connecting the hob to the gas supply via use offlexible hoses please ensure that the maximum distance covered by the hose does not exceed 2 metres. The flexible tube shall be fitted in such a way that it cannot come into contact with a moveable part of the housing unit (e. A drawer) and does not pass through any space where it may become crushed/ kinked or damaged in any way. To prevent any potential damage to the hob please carry out the installation following this sequence (picture 6): 1)As illustrated, assemble parts in sequence: A: 1/2 Male Adaptor Cylindirical B: 1/2 Seal C: 1/2 Female Gas Adaptor Conical-Cylindirical or cylindirical-Cylindirical 2)Tighten the joints with the spanner, remembering to twist the pipes into position. [. . . ] Nu permitei copiilor i persoanelor cu capabiliti fizice, senzoriale sau mentale reduse sau care nu cunosc modul de utilizare al aparatului s îl utilizeze, fr stricta supraveghere a unui adult responsabil pentru sigurana lor sau dac nu au fost instruii asupra modului de utilizare i a potenialelor pericole care pot apare în timpul utilizrii aparatului. AVERTIZARE: Nu lsai nesupravegheate recipientele în care preparai alimente cu ulei sau grsime, deoarece exist pericol de incendiu. Plita poate fi instalat în orice blat de lucru care rezist la o temperatur de pân la 100°C i are o grosime de 25-45 mm. Dac exist un spaiu care este accesibil între plita incorporabil i cavitatea de sub aceasta, este recomandat s fie fixat un panou de izolare (din lemn sau un material similar) (Figura 3). [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CANDY CFX 64 P




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual CANDY CFX 64 P will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.