User manual BEGLEC MINI COLOR 7TC V1.0

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual BEGLEC MINI COLOR 7TC. We hope that this BEGLEC MINI COLOR 7TC user guide will be useful to you.


BEGLEC MINI COLOR 7TC V1.0: Download the complete user guide (30191 Ko)

Manual abstract: user guide BEGLEC MINI COLOR 7TCV1.0

Detailed instructions for use are in the User's Guide.

[. . . ] 1. 4--PHOTOMETRIC DATA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3. 1. 5--SAFETY WARNING. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4. 5 5. 1 APPENDIX TROUBLE SHOOTING LED MODULE SITUATION CAUSE 1) Power connection error 2) Power switch damaged No display 3) Display board damaged 4) Fuse damaged LED MODULE on, 1) Keyboard damaged but no control 2) Display board damaged from display LEDs of the same LED PCB damaged color are not lit ACTION 1) Check all power connections 2) Replace power switch 3) Replace display board 4)Replace the Fuse 1) Replace keyboard 2) Replace display board Check and Replace PCB board 1) Replace main PCB board 2) Replace PCB board 1) Check and replace signal cable 2) Check and reset DMX address PART ORDER NUMBER 16-03-0030-04 26-2A-LED307DI-00 PART 2 INSTALLATION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5. 2. 1--MOUNTING. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5. 2. 2--POWER CONNECTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5. 2. 3--SETTING UP WITH A DMX512 CONTROLLER. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6. 2. 3-1--DMX512 ADDRESSING WITHOUT ID ADDRESSING. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6. [. . . ] 17. 5. 1--TROUBLE SHOOTING. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17. 5. 2--MAINTENANCE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18. 5 APPENDIX 17 2009. 12. 9 4. 3 BASIC INSTRUCTIONS FOR DMX512 OPERATION (STAGE 1) MASTER DIMMER CH1 controls the intensity of the currently projected color When the slider is at the highest position (255) the intensity of the output is the maximum RED, GREEN & BLUE COLOR SELECTION CH2, CH3 & CH4 control the intensity ratio of each of the RED, GREEN & BLUE LEDs. When the slider is at the highest position (255) the intensity of the color is the maximum. CH2, CH3 & CH4 can be combined together to create over 16 million colors. COLOR MACROS CH5 selects the required COLOR MACRO CH5 has priority over CH2, CH3 , CH4 and CH6 CH1 is used to control the intensity of the COLOR MACRO STROBE CH 6 controls the strobe of CH1 to Ch5 1 1. 1 PRODUCT (GENERAL) PRODUCT INTRODUCTION This product is designed for indoor use. Suitable applications include wash or effect lighting for architectural, stage or nightclub applications. This product can also be installed for use in signage and advertising using the dynamic functions available with DMX512 control. Direct input of DMX512 signal allows the units to be controlled from any DMX512 controller. This product can be operated as a single unit or in multiple units for large applications. The specially developed controller that allows the product to be controlled independent of the DMX512 controller enables the user to create and edit a wide range of custom programs. All programs can be touch-button displayed or scheduled to START and END at scheduled times. When programs have been created or edited in the controller, it is also possible to trigger these programs using the DMX IN function when connected to a DMX512 controller. 1. 2 PRODUCT FEATURES LED FIXTURE * RGB Dimmer 0-100% * Strobe * Automatic programs * LCD display * Display control 'lock-out' * Direct DMX512 input * Independant ID address * Stand-alone/ Slave ID ADDRESS SELECTION CH9 is used to select the target ID address. Each independent DMX address may have upto 66 independent ID addresses. AUTO CH7 selects the preset AUTO programs AT. 01-AT10 or the custom AUTO programs PR. C1-PR. 10 When activating the custom AUTO programs PR. C1 to PR. 10 then it is possible to control the Step time and fade time using Ch2 and Ch3 respectively. 4 USING A DMX512 CONTROLLER 16 2009. 12. 9 1 PRODUCT(GENERAL) 1 2009. 12. 9 1. 3 TECHNICAL SPECIFICATIONS LED MODULE CHANNEL VALUE 200 210 211 209 ID20 ID21 ID22 FUNCTION 9 LED MODULE: Voltage Rated Power LED/Unit 100~240V. . . 50/60Hz 35W 253 254 255 ID64 ID65 ID66 7 X 3W Tri-RGB ARC 1 CHANNEL 1 2 3 VALUE 0 255 Environment Temperature -20 ~40 Cooling Dimensions Weight Forced air convection 240 x 210 x160mm 2. 5Kg FUNCTION RED 0 255 GREEN 0 255 BLUE ARC 1+D CHANNEL 1 2 3 4 VALUE 0 255 FUNCTION MASTER DIMMER 0 255 RED 0 255 GREEN 0 255 BLUE RGB+D CHANNEL VALUE RED FUNCTION GREEN BLUE MASTER DIMMER 0% MASTER DIMMER 0-100% DIMMER 100% STROBE 1-20HZ DIMMER 100% RGB+DS CHANNEL VALUE RED FUNCTION GREEN BLUE MASTER DIMMER 5 NO function 0-20Hz 1 PRODUCT(GENERAL) 2 2009. 12. 9 4 USING A DMX512 CONTROLLER 15 2009. 12. 9 CHANNEL VALUE AUTO 0 21 31 41 51 61 71 81 91 101 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 255 No function AUTO 1 AUTO 2 AUTO 3 AUTO 4 AUTO 5 AUTO 6 AUTO 7 AUTO 8 AUTO 9 AUTO 10 CUSTOM 1 CUSTOM 2 CUSTOM 3 CUSTOM 4 CUSTOM 5 CUSTOM 6 CUSTOM 7 CUSTOM 8 CUSTOM 9 CUSTOM 10 No function FUNCTION 1. 4 PHOTOMETRIC DATA PHOTOMETRIC DATA RED 370 93 41 23 15 LUX 3 2 1 0 1 2 3 2(0. 23) 4(0. 43) 6(0. 56) 8(0. 93) 10Distance(m) (1. 12Diameter(m)) 7 111 121 131 141 151 161 171 181 191 201 211 221 GREEN 740 185 82 46 30 LUX 3 2 1 0 1 2 3 2(0. 24) 4(0. 41) 6(0. 69) 8(1. 02) 10Distance(m) (1. 02Diameter(m)) BLUE 156 39 17 10 6 LUX 3 2 1 0 1 2 3 2(0. 23) 4(0. 42) 6(0. 60) 8(0. 88) 10Distance(m) (1. 12Diameter(m)) 8 0 255 AUTO SPEED ADJUSTMENT When using CH7, AUTO01-AUTO9, this function activated ID ADDRESS 0 10 20 30 40 50 60 70 9 19 29 39 49 59 69 79 89 99 109 119 129 139 149 159 169 179 189 199 ID1~ID66 ID1 ID2 ID3 ID4 ID5 ID6 ID7 ID8 ID9 ID10 ID11 ID12 ID13 ID14 ID15 ID16 ID17 ID18 ID19 RGB 1174 293 130 73 47 LUX 3 2 1 0 1 2 3 2(0. 23) 4(0. 44) 6(0. 68) 8(1. 01) 10Distance(m) (1. 07Diameter(m)) 9 80 90 100 110 120 130 140 150 160 170 180 190 4 USING A DMX512 CONTROLLER 14 2009. 12. 9 1 PRODUCT(GENERAL) 15 15 15 15 3 2009. 12. 9 1. 5 SAFETY WARNING IMPORTANT ALWAYS READ THE USER MANUAL BEFORE OPERATION. PLEASE CONFIRM THAT THE POWER SUPPLY STATED ON THE PRODUCT IS THE SAME AS THE MAINS POWER SUPPLY IN YOUR AREA. A minimum distance of 0. 5m must be maintained between the equipment and combustible surface. DO NOT stand close to the equipment and stare directly into the LED light source. Always make sure that the supporting structure is solid and can support the combined weight of the products. Do not touch the power cables if your hands are wet. 4 4. 1 USING A DMX512 CONTROLLER BASIC ADDRESSING Connect all of the units in series using standard DMX512 signal cable or the IP65 rated cable provided. [. . . ] When [UC] is selected, the RGB output are adjusted to a standard preset universal color which balances fixtures from different generations. . (Note that when used in this way, the CH9 ID function must be inactive (CH9=0)) 2. 3-2 DMX512 ADDRESSING WITH ID ADDRESS (STAGE 1 MODE) Connect the DMX512 controller to the units in series Each unit has 9DMX channels so the DMX Addresses should increase by increments of 9 (e. g. 1, 10, 19, 28. . . ) Each DMX Address may be used as many times as required. 1, 2, 3. . . ) ID addresses are accessible from Ch9 on the DMX512 controller. 2 INSTALLATION 6 . . . . . . . . . . . . 3. 8 ID ID 001~066 MENU ID Enter ID and set the ID address 001~066 3. 9 EDIT EDIT custom 1 custom 2 custom 3 custom 4 custom 5 custom 6 custom 7 custom 8 custom 9 custom 10 scene 30 scene 01 scene 02 scene 03 scene 04 scene 05 scene 06 Red GREN BLUE STRB TIME FADE 000~255 000~255 000~255 000~020 000~255 000~255 MENU EDIT Enter EDIT to edit the custom programs custom 1 to custom 10 Each program has 30 steps to edit Each step allows a creation of a scene using RED, GREEN, BLUE, STRUBE, TIME, FADE 2009. 12. 9 3 DISPLAY PANEL OPERATION 11 2009. 12. 9 3. 3 STATIC STATIC RED GREN BLUE STRB 000~255 000~255 000~255 000~020 Example: DMX Addr. 1 ID Addr. 1 DMX Addr. 1 ID Addr. 2 DMX Addr. 1 ID Addr. 3 DMX Addr. 10 DMX Addr. 10 DMX Addr. 10 ID Addr. 1 ID Addr. 2 ID Addr. 3 MENU STATIC Select RED / GREN / BLUE / STRB to set the value DMX512 CONTROLLER 3. 4 AUTO AUTO AUTO 1 AUTO 2 AUTO 3 AUTO 4 AUTO 5 AUTO 6 AUTO 7 AUTO 8 AUTO 9 AUTO 10 custom 1 custom 2 custom 3 custom 4 custom 5 custom 6 custom 7 custom 8 custom 9 custom 10 MENU The figure above shows a simple DMX layout which has used three units at each DMX address. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE BEGLEC MINI COLOR 7TC




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual BEGLEC MINI COLOR 7TC will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.