User manual BEGLEC LED-UV212 VERSION 1.0

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual BEGLEC LED-UV212. We hope that this BEGLEC LED-UV212 user guide will be useful to you.


BEGLEC LED-UV212 VERSION 1.0: Download the complete user guide (1109 Ko)

Manual abstract: user guide BEGLEC LED-UV212VERSION 1.0

Detailed instructions for use are in the User's Guide.

[. . . ] Master/slave mode: several units can be used together for wonderful, music synchronized black light effects. (optional CA-8 controller possible) DMX-controlled: 2modes, 1channel (on/off), 2channel (off, variable strobe, music controlled, dimmer) Different ways to set DMX start address: Fast remote DMX addressing using any standard DMX-controller In master/slave mode you can address all units just by pushing 1 button IEC mains inputs of several units can be daisy chained. The lightning flash with arrowhead symbol within the equilateral triangle is intended to alert the use or the presence of un-insulated "dangerous voltage" within the product's enclosure that may be of sufficient magnitude to constitute a risk of electric shock. The exclamation point within the equilateral triangle is intended to alert the user to the presence of important operation and maintenance (servicing) instructions in the literature accompanying this appliance. [. . . ] You need to "daisy chain" your DMX controller and all the connected units with a good quality balanced cable. To prevent strange behavior of the light effects, due to interferences, you must use a 90 to 120 terminator at the end of the chain. Each light effect in the chain needs to have its proper start address so it knows which commands from the controller it has to decode. In the section HOW TO SETUP you will learn how to set the DMX addresses. Remember that each projector uses 1 or 2 channels, a possible address setup for 2ch mode could be: unit1 = 001 ~ unit2 = 003 ~ unit3 = 005 ~ unit4 = 007 ~ etc. Important: The electrical installation should be carried out by qualified personal only, according to the regulations for electrical and mechanical safety in your country. electrical installation for 1 standalone unit: Insert the mains cable. The unit starts working immediately in the last selected stand-alone mode. Refer to chapter HOW TO SETUP to learn how to switch between static and sound mode. Remark: You can connect a CA-8 remote controller to the unit if you want to have more control. Electrical installation for two or more units in master/slave: Connect 2 to maximum 16 units together using good quality balanced microphone cables. The unit that has no cable connected to its DMX-input is the "master", the others are the slave units. Remark: You can connect a CA-8 remote controller to the master unit if you want to have more control over the master/slave operation. Important: The installation must be carried out by qualified service personal only. Improper installation can result in serious injuries and/or damage to property. Working load limits should be respected, certified installation materials should be used, the installed device should be inspected regularly for safety. Make sure the area below the installation place is free from unwanted persons during rigging, de-rigging and servicing. The device should be installed out of reach of people and outside areas where persons may walk by or be seated. Before rigging make sure that the installation area can hold a minimum point load of 10times the device's weight. Always use a certified safety cable that can hold 12times the weight of the device when installing the unit. This secondary safety attachment should be installed in a way that no part of the installation can drop more than 20cm if the main attachment fails. The device should be well fixed; a free-swinging mounting is dangerous and may not be considered! [. . . ] Refer to the chapter "Electrical installation for two or more units in DMXmode" to learn how to do this (don't forget to address all units properly!Since each unit has its own DMX-address, you can control them individually. Remember that each unit uses 1 or 2 DMX-channels as shown in the DMX chart below: Mains Input: Power consumption: Fuse: IEC input/output daisy chaining: Sound Control: DMX connections: LEDs: Beam angle: Size: Weight: 100 - 240V 50/60Hz 25Watt 250V 6, 3A slow blow (20mm glass) 50pcs Internal microphone XLR 3pin 212 high power UV-LEDs 15° see drawing below 1, 6kg Every information is subject to change without prior notice You can download the latest version of this user manual on our website: www. Ce symbole signifie: appareil construit selon les normes de sécurité classe I Ce symbole représente la distance de recul minimum à respecter, c'est-à-dire, la distance minimum entre le projecteur et la surface à éclairer. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE BEGLEC LED-UV212




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual BEGLEC LED-UV212 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.