User manual BEGLEC IROCK 7S-7B VERSION 1.0
DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual BEGLEC IROCK 7S-7B. We hope that this BEGLEC IROCK 7S-7B user guide will be useful to you.
Manual abstract: user guide BEGLEC IROCK 7S-7BVERSION 1.0
Detailed instructions for use are in the User's Guide.
[. . . ] Locate the fixture in a well ventilated spot, away from any flammable materials and/or liquids. Don't cover any ventilation openings as this may result in overheating. Make sure the area below the installation place is free from unwanted persons during rigging, de-rigging and servicing. Allow the device about 10 minutes to cool down before replacing the bulb or start servicing. [. . . ] If you touched the lamp, clean it with a cloth and a little denatured alcohol. Important: The installation must be carried out by qualified service personal only. Improper installation can result in serious injuries and/or damage to property. Working load limits should be respected, certified installation materials should be used, the installed device should be inspected regularly for safety. Make sure the area below the installation place is free from unwanted persons during rigging, de-rigging and servicing. Locate the fixture in a well ventilated spot, far away from any flammable materials and/or liquids. The device should be installed out of reach of people and outside areas where persons may walk by or be seated. Before rigging make sure that the installation area can hold a minimum point load of 10times the device's weight. Always use a certified safety cable that can hold 12times the weight of the device when installing the unit. This secondary safety attachment should be installed in a way that no part of the installation can drop more than 20cm if the main attachment fails. The device should be well fixed; a free-swinging mounting is dangerous and may not be considered!Don't cover any ventilation openings as this may result in overheating. The operator has to make sure that the safety-relating and machine-technical installations are approved by an expert before using them for the first time. The installations should be inspected every year by a skilled person to be sure that safety is still optimal. never unscrew the screws of the rotating gobo as the ball bearing will be opened. Open the plastic top cover (4screws) Locate the gobo wheel and remove the fixation ring of the gobo you want to change with an appropriate tool. Press the fixation-ring together and insert it in the front of the gobo. REMOTE CONTROL INPUT: Used to connect a optional CA-8 hand controller while the unit is used in standalone or master/slave mode. SENSITIVITY: Used to adjust the sensitivity of the micro when the unit is used in standalone or master/slave mode. Blackout Mode Blackout mode: when no DMX-signal is detected, the unit goes in blackout and waits for the DMXsignal. No blackout mode: when no DMX-signal is detected, the unit automatically switches to standalone mode. (or automatically return to the main functions without any change after 8 seconds) To go back to the functions without any change press the MENU button again. [. . . ] When an optical lens is visibly damaged due to cracks or deep scratches, it must be replaced. The mains cables must be in impeccable condition and should be replaced immediately when even a small problem is detected. In order to protect the device from overheat the cooling fans (if any) and ventilation openings should be cleaned monthly. The interior of the device should be cleaned annually using a vacuum cleaner or air-jet. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE BEGLEC IROCK 7S-7B
Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual BEGLEC IROCK 7S-7B will begin.