User manual ASUS MAXIMUS-VI-GENE-C2

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual ASUS MAXIMUS-VI-GENE-C2. We hope that this ASUS MAXIMUS-VI-GENE-C2 user guide will be useful to you.


ASUS MAXIMUS-VI-GENE-C2 : Download the complete user guide (9921 Ko)

Manual abstract: user guide ASUS MAXIMUS-VI-GENE-C2

Detailed instructions for use are in the User's Guide.

[. . . ] MAXIMUS VI GENE Motherboard E8458 Revised Edition V2 June 2013 Copyright © 2013 ASUSTeK COMPUTER INC. No part of this manual, including the products and software described in it, may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language in any form or by any means, except documentation kept by the purchaser for backup purposes, without the express written permission of ASUSTeK COMPUTER INC. Product warranty or service will not be extended if: (1) the product is repaired, modified or altered, unless such repair, modification of alteration is authorized in writing by ASUS; or (2) the serial number of the product is defaced or missing. ASUS PROVIDES THIS MANUAL “AS IS” WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OR CONDITIONS OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. [. . . ] Configuration options: [Auto] [Disabled] [Enabled] Initial PLL Termination Voltage [Auto] Initial Voltage at which CPU BCLKs are terminated. Maintaining a level close to CPU Input Voltage will help BCLK Overclock. Configuration options: [Auto] [0. 0000] - [3. 0000] PLL Termination Reset Voltage [Auto] PLL Termination Reset Voltage. Configuration options: [Auto] [0. 0000] - [3. 0000] Eventual PLL Termination Voltage [Auto] PCH ICC Voltage [Auto] Eventual PLL Termination Voltage. Configuration options: [Auto] [0. 0000] - [3. 0000] Power Supply for the Integrated Clock Controller. Configuration options: [Auto] [0. 6000] -[2. 2000] ICC Ringback Canceller [Auto] ICC Ringback Canceller can be used to control the noise level at the Integrated Clock Controller. Clock Crossing VBoot [Auto] The instantaneous voltage value when the rising edge of BCLK DN is equal to the falling edge of the BCLK DP. Configuration options: [Auto] [0. 1000] - [1. 9000] Clock Crossing Reset Voltage [Auto] The instantaneous voltage value when the rising edge of BCLK DN is equal to the falling edge of the BCLK DP. Configuration options: [Auto] [0. 1000] - [1. 9000] Clock Crossing Voltage [Auto] The instantaneous voltage value when the rising edge of BCLK DN is equal to the falling edge of the BCLK DP. Configuration options: [Auto] [0. 1000] - [1. 9000] BCLK Amplitude [Auto] Allows you to adjust the magnitude of the BCLK. Configuration options: [Auto] [+5] - [-5] Tweakers’ Paradise Chapter 3 3-20 Chapter 3: BIOS setup DMI Gen 2 [Auto] Allows you to enable or disable DMI Gen 2. Configuration options: [Auto] [Enabled] [Disabled] DMI De-emphasis Control [-6 dB] SATA Drive Strength [Auto] PCIE Tuning Configure De-emphasis control on DMI. Configuration options: [Auto] [+10] - [-10] Internal Graphics [Auto] CPU Power Management Keep IGD enabled based on setup options. Configuration options: [Auto] [Disabled] [Enabled] The subitems in this menu allow you to set the CPU ratio and features. Enhanced Intel SpeedStep Technology [Enabled] Allows the operating system to dynamically adjust the processor voltage and cores frequency to decrease the average power consumption and decrease average heat production. Configuration options: [Enabled] [Disabled] Turbo Mode [Enabled] Allows you to enable your processor cores to run faster than the base operating frequency when it is below power, current and specification limit. Configuration options: [Disabled] [Enabled] The following items appear only when you set the Turbo Mode to [Enabled]. Turbo Mode Parameters Long Duration Package Power Limit [Auto] Allows you to limit the Turbo Ratio’s time duration thay exceeds the TDP (Thermal Design Power) for maximum performance. The values range from 1W to 4096W. Package Power Time Window [Auto] Also known as Power Limit 1, and allows you to maintain the time window for Turbo Ratio over TDP (Thermal Design Power). The values range from 1 second to 127 seconds. CPU Integrated VR Current Limit [Auto]* Allows you to set a higher current limit to prevent frequency and power throttling when overclocking. The values range from 0. 125 to 1023. 875 with a 0. 125 interval. ASUS MAXIMUS VI GENE 3-21 Chapter 3 Short Duration Package Power Limit [Auto] Also known as Power Limit 2, and allows you to provide rapid protection when the package power exceeds the Power Limit 1. The values range from 1W to 4096W. CPU Internal Power Switching Frequency Frequency Tuning Mode [Auto] Allows you to increase or decrease the switching frequency of the internal regulator. Decrease to help consume less power or increase to help voltage stability. [. . . ] Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment. ASUS MAXIMUS VI GENE A-1 Appendices IC: Canadian Compliance Statement Complies with the Canadian ICES-003 Class B specifications. This Class B device meets all the requirements of the Canadian interference-causing equipment regulations. This device complies with Industry Canada license exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Cut appareil numérique de la Classe B est conforme à la norme NMB-003 du Canada. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ASUS MAXIMUS-VI-GENE-C2




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual ASUS MAXIMUS-VI-GENE-C2 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.