If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual APPLIED ENERGY SLIM100. We hope that this APPLIED ENERGY SLIM100 user guide will be useful to you.
Manual abstract: user guide APPLIED ENERGY SLIM100
Detailed instructions for use are in the User's Guide.
[. . . ] -
SL100 SL100T SL150 SL150HT
-
SL100P SL100HT SL150P
Slimline Axial Fan Range
Installation and maintenance instructions
SLIMLINE Series
IPX4
INSTALLATION: Begin the installation by making a circular opening of 100 mm (SL100), 150 mm (SL150) diameter in the ceiling or wall where the extractor is to be installed. Remove the front cover (A) by removing screw (SL150 only) and pressing the catch (1) with the tip of a screwdriver until it is freed and then pulling it forward. Place the exhaust conduit (D) in the hole in the ceiling or wall for exhaust of the air. [. . . ] -- This extractor is designed for the ventilation of homes or similar premises. -- This extractor does not cause any interference in radio/television sets (C. E. E. ELECTRICAL CONNECTION: The unit must be connected to a single phase mains power supply network at the voltage and frequency indicated on the rating plate of the extractor unit. The electrical installation must include a double pole isolating switch with a distance between contacts of at least 3 mm. Make the electrical connection by loosening the screw (2) until the cover (3) is free and connect the power supply cables to the connection strip (E), the blue cable to N and the brown cable to L. Replace the cover (3), fixing it in place with the screw (2) and finally press home the cover (A) until it is firmly held by the clip (7) and the catch (1) (Fig. The appliance must be permanently connected to a fixed electrical supply installation using twin conductor cable of at least 1 mm2 in section and a maximum of 1. 5 mm2. No earth installation is required as the appliance has double insulation. IPX4 NOTE: TIMER and HUMIDITY connection Must he carried out by following the wiring diagram for SL100T / SL100HT / SL150HT. Connect the wires to the connection strip by using a pointed instrument (the tip of a screwdriver for example) to apply pressure to (x) (xl, x2, x3) and pushing the striped wires (L. SL100T IPX4 Adjust the timer by turning the knob (4) in a clockwise direction to increase the operating time (3' 15'). SL100HT and SL150HT IPX4 Adjust the operating time by turning the red knob (4) in a clockwise direction. Adjust the level of humidity by turning the blue knob (5) in a clockwise direction to increase the level. The LED is lit when the extractor is functioning either activated by the switch fitted to the appliance itself or another, exterior switch. When the extractor is activated by the level of humidity the LED is not lit. SL100P and SL150P IPX4 This model is fitted with a Start/stop pull-switch (6) (Fig. [. . . ] · Technical Advice and Service: Contact your local Xpelair distributor
Applied Energy Products Ltd Morley Way Peterborough PE2 9JJ t 01733 456789 f 01733 310606 www. applied-energy. com
Xpelair is a registered trademark of Applied Energy Products Limited. Applied Energy Products reserve the right to alter product specifications or appearance without prior notice. All finishes and diagrams in this booklet are as accurate as printing processes allow. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE APPLIED ENERGY SLIM100
Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual APPLIED ENERGY SLIM100 will begin.