If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual APPLIED ENERGY LVDX200. We hope that this APPLIED ENERGY LVDX200 user guide will be useful to you.
Manual abstract: user guide APPLIED ENERGY LVDX200
Detailed instructions for use are in the User's Guide.
[. . . ] IF ANY SECTION OF THE DUCTWORK IS POSITIONED HIGHER THAN THE FAN A CONDENSATION TRAP (XCT100) MUST BE FITTED AS CLOSE AS POSSIBLE TO THE FAN. THIS APPLIANCE IS NOT INTENDED FOR USE BY YOUNG CHILDREN OR INFIRM PERSONS WITHOUT SUPERVISION. YOUNG CHILDREN SHOULD BE SUPERVISED TO ENSURE THEY DO NOT PLAY WITH THE APPLIANCE. The correct condensation control speed should indicated in "Ancillary Options". [. . . ] Ensure that the Preparing the fan for installation cable grommet is in place and a tight fit. or to the ceiling using appropriate fasteners impeller can be removed to ease access (if (not supplied). Setting the condensation speed If mounting the fan in a wall (flush mounting) The surround ?to the wooden frame using the slots in the flange (screws not supplied). into the hole and mark four positions using the slots in the flange B. from ceiling and fit the four ceiling clips (supplied) over the edge of the hole, so that the clips align with the marks on the ceiling B. Drill 4 pilot holes into the ceiling through the hole of each clip, ensuring not to damage the clip, and fit the clips ensuring correct alignment. Using the screws 11 (Fig B), fix the fan box flange to the ceiling clips. Terminating the ducting Fit an outer grille (CF20 variants only) to the outer wall. Mounting the transformer The transformer A can be fixed directly to the wall. The transformer can be sited in a loft or in a convenient position on a wall (not ceiling). For wall mounting the Fan must be orientated as shown in H to fulfil ingress protection requirements. 2.
F
2
7
E
The transformer must also not be mounted within 0. 6m of a bath or shower cubicle, up to a height of 2. 25m. The transformer must not be mounted where ambient temperatures are likely to exceed 40°C. Drill and plug the two holes and fix the transformer with the screws supplied. For loft mounting: The transformer can be fixed to a wooden surface with the two screws supplied. For fixed surface wiring: Use the rectangular knockouts on each side (X). These accept 25 x 16mm trunking (not supplied) For concealed wiring: Use the round knockouts (Y). When using the side entries with flexible cable, a hole suitable for the cable size must be made centrally in the rectangular section. A means for disconnection in all poles must be incorporated in the fixed wiring in accordance with the wiring rules. Remove the retaining screws of the terminal cover ·, if still in position. LVDX200T: "LH" = Live (High Speed) / "LL" = Live (Low Speed) 6. [. . . ] (If a change over switch has been VK10 installed then the user can switch between high FD100 WDC5 speed and low speed. ) XCMK XBP Time delay start feature on or off This is set by the installer to provide a 2-minute time EFT delay start when the fan is switched on using the GMK PDXGF external on/off switch. FDA LVCF20 / LVCF20T Spares Switched Operation Listed below are some of the spares available. back page of this booklet for ordering details: Fan operates at condensation speed when switched on. Top light "I" is lit when the separate on/off 41756SK Motor (LVDX200T) switch is switched on. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE APPLIED ENERGY LVDX200
Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual APPLIED ENERGY LVDX200 will begin.