User manual APPLIED ENERGY GX6EC2

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual APPLIED ENERGY GX6EC2. We hope that this APPLIED ENERGY GX6EC2 user guide will be useful to you.


APPLIED ENERGY GX6EC2 : Download the complete user guide (389 Ko)

Manual abstract: user guide APPLIED ENERGY GX6EC2

Detailed instructions for use are in the User's Guide.

[. . . ] It is the responsibilty of the installer to check that the installation parameters meet the requirements of the product, and any relevant regulations. If we are called out to a fault, which is subsequently identified as being an installation fault, we will make a charge. It is important that the routine checks are completed before calling us out, as many issues can be simply diagnosed and resolved. We will endeavour to achieve the most timely response possible but while we indicate an average response time, this should not be taken as a guarantee. [. . . ] Refit the back draught shutter/grille assembly by sliding the grille back over the release catches, the catches will locate and secure the grille. Connect the cable from the isolation switch to the electrical supply wiring. For fixed wiring circuits the protective fuse for the appliances must not exceed 5A. Operating the fan 2. Push down firmly on the trickle vent catch until it clicks into position then release the shutter vanes, see Fig. Pull the trickle vent catch towards you until it clicks into position. Refit the back draught shutter/grille assembly, see "Wire the electrical connections" section, ensuring that the actuator lever is in the "fully down" position. Maintenance A QUALIFIED ELECTRICIAN MUST CARRY OUT ALL CLEANING. NOTE: THE FAN WILL CONTINUE TO OPERATE WITH THE INNER GRILLE REMOVED HENCE IT MUST BE ISOLATED COMPLETELY FROM THE MAINS BEFORE ANY WORK IS CARRIED OUT. Before cleaning, isolate the fan completely from the mains electricity supply. On the GX6 EC2, allow 3 minutes for the impeller to stop rotating and the powered shutter to close. Cleaning on the GXC6 EC2 can begin once the impeller has stopped rotating. Remove the back draught shutter/grille assembly by pressing the release catch located on the side of the unit with a 6mm screwdriver or a coin, whilst pulling the grille forward. To remove the back draught shutter, lay face down and pull the shutter forwards, see Fig. G2. · · These fans can either be single speed operation with a choice between High and Low at installation, or 2 speed operation when installed with a change over switch (COS). The shutters of the GX6 EC2 have a time delay of up to 1 minute on opening and up to 3 minutes on closing. Activated by operation of the switch, the delay ensures quiet operation. 4 9 Installing the switches and cables 1. Electricity, gas, water) behind the switch location (in the wall or above the ceiling). Lay in the cable from the isolating switch to the fan location via the on/off switch (see Fig. Lay in the cable from the isolating switch to the point of connection to the mains supply. WARNING: DO NOT MAKE ANY CONNECTIONS TO THE ELECTRICITY SUPPLY AT THIS STAGE. Make all connections within the isolating switch, on/off switch and change over switch (COS) if required. Note: When installed in a bathroom all switches must be of a pull cord type and must be situated so that they can not be touched by persons making use of the bath or shower. For Australia only the cutting line and remove the brick between the holes with a chisel). Go outside and cut a hole in the outer wall, repeating the process described above. [. . . ] Suitably rated 2-core cable for single speed operation, and a link wire if required to select Low speed. 6mm blade large screwdriver, 3mm blade electrician's screwdriver and No. 7mm nut runner (for removing the impeller when cleaning). If window mounting the fan, you will also need: GXC6 EC2 · · · · · · · · Integral pull cord operation. 2 speed operation when installed with a change over switch (COS) not supplied, see Fig. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE APPLIED ENERGY GX6EC2




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual APPLIED ENERGY GX6EC2 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.