User manual APPLIED ENERGY GX6

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual APPLIED ENERGY GX6. We hope that this APPLIED ENERGY GX6 user guide will be useful to you.


APPLIED ENERGY GX6 : Download the complete user guide (3547 Ko)

Manual abstract: user guide APPLIED ENERGY GX6

Detailed instructions for use are in the User's Guide.

[. . . ] If installed in a kitchen, fans must This appliance is intended for Integral pull cord operation. All installations must be supervised air to prevent fumes being drawn Solenoid operated back draught by a qualified electrician. Down the flue when the fan is shutters, for instant opening and Installation and wiring must conform operating up to maximum extract. Exhaust air GX6 (IP25) must not be discharged into a flue (other countries). [. . . ] Remove the Back Draught Shutter/Grille Assembly, by pressing the release catches located on the sides of the unit with a 6mm screwdriver or coin, whilst pulling the grille forward. Reposition the cable and fan assembly as before, and screw securely in place. Note: For particularly difficult installations, it is possible to secure the fan with a combination of screw and ladder strip fixings. If working above ground level, appropriate safety precautions must be observed. Hold up the outer grille to the outside of the wall or window so that the hole in the outer grille is aligned with the hole in the wall or window. If wiring from the rear, remove the fans terminal cover and rear entry knockout. Check there are no buried pipes terminal cover and feed the cable or cables in the wall or obstructions through the top cable entry. Ensure that the centre of the hole Pierce the cable entry grommet with is located at least 145mm from the a No. Of the wall or window and guide the If core drill equipment is available ladder strips from the outer grille through the slots in the fan 5a. Insert the slotted screws into the If core drill equipment is not pockets around the ladder strip slots. Do not cut right required length, if necessary remove through the wall (the recommended any sharp edges. Method is to drill a series of holes, If using screw fixings close together, around the edge of the cutting line and remove the brick 1. Go outside and cut a hole in the the outer grille is aligned with the outer wall, repeating the process hole in the wall. Ensuring that the in the top right and bottom left duct slopes down away from the fan corners. Screw the outer grille securely in to set before continuing with the place and fit screw caps in place. Insert the two screw covers in the two fixing holes in the outer grille. If wiring from above, remove the fans terminal cover and feed the cable 1. For Wall mounting, use the longer Pierce the cable entry grommet with strips supplied with the wall kit a no. Refit the back draught shutter/grille assembly by sliding the grille back over the release catches, the catches will locate and secure the grille. For fixed wiring circuits the protective fuse for the appliances must not exceed 5A. E3), cut off the pull cord after ensuring that it is in the "off" position. This switch must be marked with suitable markings to indicate speed control. [. . . ] Turn the adjuster marked "H" anticlockwise to decrease the relative humidity level of the room (see Fig. Turn the adjuster clockwise to increase the relative humidity level of the room (see Fig. Clean the back draught shutter/grille provided by an airbrick or similar device. Shutter/grille assembly and refit by Boost operation sliding the grille back over the realise The integral pull cord switches the fan To allow trickle ventilation catches, the catches will locate in and on to run at high speed. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE APPLIED ENERGY GX6




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual APPLIED ENERGY GX6 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.